HTS003M
ChemiSCREEN Membrane Preparation Recombinant Human CXCR3 Chemokine Receptor
Human CXCR3 GPCR membrane preparation for Radioligand binding Assays.
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Origine biologica
human
Livello qualitativo
Ricombinante
expressed in Chem-1 cells
Produttore/marchio commerciale
ChemiScreen
Chemicon®
Concentrazione
1.0 mg/mL
tecniche
radioligand binding assay (RLBA): suitable
N° accesso NCBI
N° accesso UniProt
Condizioni di spedizione
dry ice
Descrizione generale
CXCR3 is a 7-TM GPCR that is selective for the CXC chemokines IP10, ITAC and MIG (Loetscher et al., 1996). Binding of IP10 and MIG to CXCR3 induces Ca2+ mobilization, chemotaxis and inflammatory responses of T lymphocytes, and also act as potent inhibitors of angiogenesis. CXCR3 is highly expressed in IL-2-activated T lymphocytes in vitro (Loetscher et al., 1996), and in T lymphocytes present in inflamed tissues in rheumatoid arthritis and multiple sclerosis (Balashov et al., 1999; Qin et al., 1998). In vivo, neutralization of CXCR3 inhibits experimentally induced type I diabetes (Frigerio et al., 2002), peritonitis (Xie et al., 2003), and post-lung transplantation bronchiolitis obliterans syndrome (Belperio et al., 2002). Millipore’s ChemiScreenTM CXCR3 receptor membrane preparations are ideal tools for screening for antagonists of CXCR3 interactions with its ligands. With 0.1 nM 125I-labeled IP10, the CXCR3 membrane preparation at 5 μg/well gives a signal:bakground of greater than 10-fold.
TRANSFECTION: Full-length human CXCR3 cDNA
Azioni biochim/fisiol
Protein Target: CXCR3
Qualità
Table 1. Signal:background and specific binding values obtained in a competition binding assay with CXCR3 membrane prep.
SPECIFICATIONS: 1 unit = 5 µg
Bmax for [125I]IP-10 binding: 0.6 pmol/mg protein
Kd for [125I]IP-10 binding: ~ 0.2 nM
10 µg/well | |
---|---|
Signal:Background | 28.2 |
Specific Binding (cpm) | 6028 |
SPECIFICATIONS: 1 unit = 5 µg
Bmax for [125I]IP-10 binding: 0.6 pmol/mg protein
Kd for [125I]IP-10 binding: ~ 0.2 nM
Specifiche
Inucbation Conditions
RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FC 96-well harvest plate (Millipore cat. # MAHF C1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.
Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C
Radioligand: [125I] IP10 (Perkin Elmer #NEX348)
Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl , 0.1% BSA, filtered and stored at 4°C.
One package contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 10-fold signal:background with 125I-labeled IP10 at 0.1 nM
RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FC 96-well harvest plate (Millipore cat. # MAHF C1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.
Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C
Radioligand: [125I] IP10 (Perkin Elmer #NEX348)
Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl , 0.1% BSA, filtered and stored at 4°C.
One package contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 10-fold signal:background with 125I-labeled IP10 at 0.1 nM
Note legali
CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
Codice della classe di stoccaggio
12 - Non Combustible Liquids
Classe di pericolosità dell'acqua (WGK)
WGK 2
Punto d’infiammabilità (°F)
Not applicable
Punto d’infiammabilità (°C)
Not applicable
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.