Cartucce Durapore® a matrice caricata da 0,22 µm
cartridge nominal length 30 in. (75 cm), filter diam. 2.7 in. (6.9 cm), Code 5
About This Item
Prodotti consigliati
Materiali
polypropylene device
polypropylene support
silicone seal
Livello qualitativo
Sterilità
non-sterile
Compatibilità con la sterilizzazione
autoclavable compatible
steam-in-place compatible
Nome Commerciale
Durapore®
Caratteristiche
hydrophilic
Produttore/marchio commerciale
Durapore®
Parametri
≤30 mL/min air diffusion at 2.1 bar (30 psig) (in water)
0.35 bar max. differential pressure (5 psid) at 135 °C (forward)
0.35 bar max. inlet pressure (5 psi) at 135 °C (forward)
1.7 bar max. differential pressure (25 psid) at 80 °C (forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (forward)
3.5 bar max. differential pressure (50 psid) at 25 °C (reverse)
3.5 bar max. inlet temp. (50 psi) at 25 °C (reverse)
45 L/min flow rate at 400 mbar (ΔP)
5.5 bar max. differential pressure (80 psid) at 25 °C (forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (forward)
tecniche
sterile filtration: suitable
Lunghezza
30 in.
Larghezza
2.7 in.
Lunghezza nominale della cartuccia
30 in. (75 cm)
device size
30 in.
Diam. filtro
2.7 in. (6.9 cm)
filter filtration area
2.07 m2
Impurezze
≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Estraibili (gravimetria)
≤20 mg/cartridge
Matrice
Charged Durapore®
Dimensione pori
0.22 μm pore size
Punto di bolla
≥2760 mbar (40 psig), air with water
Codice
Code 5
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Descrizione generale
Cartridge type: Liquid
Confezionamento
Nota sulla preparazione
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Risultati analitici
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 500 mL
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer to Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Note legali
Non trovi il prodotto giusto?
Prova il nostro Motore di ricerca dei prodotti.
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.