Saltar al contenido
Merck
Todas las fotos(2)

Documentos clave

1.05033

Supelco

Hidróxido de potasio

pellets for analysis EMSURE®

Sinónimos:

Potasa cáustica

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
KOH
Número de CAS:
Peso molecular:
56.11
Número MDL:
Código UNSPSC:
12352305
Número índice de la CE:
215-181-3
NACRES:
NA.21
Ensayo:
≥85.0% KOH basis (acidimetric)
Formulario:
solid
solubilidad:
1130 g/L
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Agency

suitable for SM 5210

Nivel de calidad

presión de vapor

1 mmHg ( 719 °C)

Línea del producto

EMSURE®

Ensayo

≥85.0% KOH basis (acidimetric)

Formulario

solid

potencia

333 mg/kg LD50, oral (Rat)

pH

14 (20 °C, 56 g/L in H2O)

mp

361 °C (lit.)

solubilidad

1130 g/L

trazas de anión

carbonate (K2CO3): ≤1.0%
chloride (Cl-): ≤0.005%
phosphate (PO43-): ≤0.0005%
silicate (as SiO2): ≤0.005%
sulfate (SO42-): ≤0.0005%

trazas de catión

Al: ≤0.001%
Ca: ≤0.001%
Cu: ≤0.0002%
Fe: ≤0.0005%
N: ≤0.0005%
Na: ≤0.5%
Ni: ≤0.0005%
Pb: ≤0.0005%
Zn: ≤0.0025%
heavy metals (as Pb): ≤0.0005%

temp. de almacenamiento

2-30°C

cadena SMILES

[OH-].[K+]

InChI

1S/K.H2O/h;1H2/q+1;/p-1

Clave InChI

KWYUFKZDYYNOTN-UHFFFAOYSA-M

¿Está buscando productos similares? Visita Guía de comparación de productos

Nota de análisis

Valoración (acidimétrica, KOH): ≥ 85,0 %
Carbonatos (como K ₂CO₃): ≤ 1,0 %
Cloruros (Cl): ≤ 0,005 %
Fosfatos (PO₄): ≤ 0,0005 %
Silicatos (SiO₂): ≤ 0,005 %
Sulfatos (SO₄): ≤ 0,0005 %
Nitrógeno total (N): ≤ 0,0005 %
Metales pesados (como Pb): ≤ 0,0005 %
Al (Aluminio): ≤ 0,001 %
Ca (Calcio): ≤ 0,001 %
Cu (Cobre): ≤ 0,0002 %
Fe (Hierro): ≤ 0,0005 %
Na (Sodio): ≤ 0,5 %
Ni (Níquel): ≤ 0,0005 %
Pb (plomo): ≤ 0,0005 %
Zn (Cinc): ≤ 0,0025 %

Información legal

EMSURE is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogramas

CorrosionExclamation mark

Palabra de señalización

Danger

Frases de peligro

Clasificaciones de peligro

Acute Tox. 4 Oral - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

Código de clase de almacenamiento

8B - Non-combustible corrosive hazardous materials

Clase de riesgo para el agua (WGK)

WGK 1

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Artículos

Compare PAH determination in olive oil: traditional GB 5009.265-2021 method vs. faster, simpler SPE with Supelclean EZ-POP NP; both meet criteria.

Compare PAH determination in olive oil: traditional GB 5009.265-2021 method vs. faster, simpler SPE with Supelclean EZ-POP NP; both meet criteria.

Compare PAH determination in olive oil: traditional GB 5009.265-2021 method vs. faster, simpler SPE with Supelclean EZ-POP NP; both meet criteria.

Compare PAH determination in olive oil: traditional GB 5009.265-2021 method vs. faster, simpler SPE with Supelclean EZ-POP NP; both meet criteria.

Contenido relacionado

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Questions

1–2 of 2 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico