跳转至内容
Merck
  • Porous silica particles grafted with an amphiphilic side-chain polymer as a stationary phase in reversed-phase high-performance liquid chromatography.

Porous silica particles grafted with an amphiphilic side-chain polymer as a stationary phase in reversed-phase high-performance liquid chromatography.

Journal of separation science (2015-05-07)
Md Shahruzzaman, Makoto Takafuji, Hirotaka Ihara
摘要

The amphiphilic polymer-grafted silica was newly prepared as a stationary phase in high-performance liquid chromatography. Poly(4-vinylpyridine) with a trimethoxysilyl group at one end was grafted onto porous silica particles and the pyridyl side chains were quaternized with 1-bromooctadecane. The obtained poly(octadecylpyridinium)-grafted silica was characterized by elemental analysis, diffuse reflectance infrared Fourier transform spectroscopy and Brunauer-Emmett-Teller analysis. The degree of quaternization of the pyridyl groups on the obtained stationary phase was estimated to be 70%. The selective retention behaviors of polycyclic aromatic hydrocarbons including some positional isomers were investigated using poly(octadecylpyridinium)-grafted silica as an amphiphilic polymer stationary phase in high-performance liquid chromatography and results were compared with commercially available polymeric octadecylated silica and phenyl-bonded silica columns. The results indicate that the selectivity toward polycyclic aromatic hydrocarbons exhibited by the amphiphilic polymer stationary phase is higher than the corresponding selectivity exhibited by a conventional phenyl-bonded silica column. However, compared with the polymeric octadecylated silica phase, the new stationary phase presents similar retention behavior for polycyclic aromatic hydrocarbons but different retention behavior particularly for positional isomers of disubstituted benzenes as the aggregation structure of amphiphilic polymers on the surface of silica substrate has been altered during mobile phase variation.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
2,2′-偶氮(2-甲基丙腈), 98%
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
(3-巯基丙基)三甲氧基硅烷, 95%
Sigma-Aldrich
甲醇, JIS special grade, ≥99.8%
Sigma-Aldrich
4-乙烯基吡啶, contains 100 ppm hydroquinone as inhibitor, 95%
Sigma-Aldrich
2,2′-偶氮(2-甲基丙腈), recrystallized from methanol, 99%
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
甲醇, SAJ first grade, ≥99.5%
Sigma-Aldrich
乙腈 溶液, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
乙腈 溶液, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
1-溴十八烷, ≥97.0%
Sigma-Aldrich
甲醇, suitable for HPLC
Supelco
乙腈, HPLC grade, ≥99.93%
Sigma-Aldrich
甲醇, SAJ special grade
Sigma-Aldrich
乙腈, ≥99.8%, suitable for HPLC
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, 99.93%
Sigma-Aldrich
甲醇, NMR reference standard
Sigma-Aldrich
乙腈, ≥99.8%, for residue analysis, JIS 300
Sigma-Aldrich
乙腈, JIS special grade, ≥99.5%
Sigma-Aldrich
乙腈, ≥99.5%, ACS reagent
Sigma-Aldrich
甲醇 溶液, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
甲醇, JIS 300, ≥99.8%, for residue analysis
Sigma-Aldrich
乙腈 溶液, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Supelco
甲醇 溶液, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
甲醇-12C, 99.95 atom % 12C
Sigma-Aldrich
2,2′-偶氮(2-甲基丙腈), SAJ first grade, ≥98.0%
Sigma-Aldrich
乙腈, SAJ first grade, ≥99.0%