跳转至内容
Merck
  • Rapid determination of thiamine, riboflavin, niacinamide, pantothenic acid, pyridoxine, folic acid and ascorbic acid in Vitamins with Minerals Tablets by high-performance liquid chromatography with diode array detector.

Rapid determination of thiamine, riboflavin, niacinamide, pantothenic acid, pyridoxine, folic acid and ascorbic acid in Vitamins with Minerals Tablets by high-performance liquid chromatography with diode array detector.

Journal of pharmaceutical and biomedical analysis (2012-07-13)
Pengfei Jin, Lufeng Xia, Zheng Li, Ning Che, Ding Zou, Xin Hu
摘要

A simple, isocratic, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed for the rapid determination of thiamine (VB(1)), niacinamide (VB(3)), pyridoxine (VB(6)), ascorbic acid (VC), pantothenic acid (VB(5)), riboflavin (VB(2)) and folic acid (VB(9)) in Vitamins with Minerals Tablets (VMT). An Alltima C(18) column (250 mm × 4.6 mm i.d., 5 μm) was used for the separation at ambient temperature, with 50mM ammonium dihydrogen phosphate (adjusting with phosphoric acid to pH 3.0) and acetonitrile as the mobile phase at the flow rate of 0.5 ml min(-1). VB(1), VB(3), VB(6), VC and VB(5) were extracted with a solution containing 0.05% phosphoric acid (v/v) and 0.3% sodium thiosulfate (w/v), and were then simultaneously analyzed by using the mobile phase of phosphate buffer-acetonitrile (95:5, v/v), while VB(2) and VB(9) were extracted with a solution containing 0.5% ammonium hydroxide solution (v/v), and were then simultaneously analyzed by using the mobile phase of phosphate buffer-acetonitrile (85:15, v/v). The detection wavelengths were 275 nm for VB(1), VB(3), VB(6), VC, 210 nm for VB(5), and 282 nm for VB(2) and VB(9). The method showed good system suitability, sensitivity, linearity, specificity, precision, stability and accuracy. All the seven water-soluble vitamins were well separated from other ingredients and degradation products. Method comparison indicated good concordance between the developed method and the USP method. The developed method was reliable and convenient for the rapid determination of VB(1), VB(3), VB(6), VC, VB(5), VB(2) and VB(9) in VMT.

材料
货号
品牌
产品描述

Sigma-Aldrich
氢氧化铵 溶液, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
氢氧化铵 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
硫代硫酸钠, ReagentPlus®, 99%
Sigma-Aldrich
磷酸二氢铵, ACS reagent, ≥98%
Sigma-Aldrich
硫代硫酸钠 五水合物, ACS reagent, ≥99.5%
Sigma-Aldrich
磷酸铵 二元, ACS reagent, ≥98%
Sigma-Aldrich
氢氧化铵 溶液, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
硫代硫酸钠, purum p.a., anhydrous, ≥98.0% (RT)
Sigma-Aldrich
氢氧化铵 溶液, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
Sigma-Aldrich
硫代硫酸钠 五水合物, puriss., meets analytical specification of Ph. Eur., BP, USP
Sigma-Aldrich
磷酸二氢铵, ReagentPlus®, ≥98.5%
Sigma-Aldrich
磷酸二氢铵, ≥99.99% trace metals basis
Sigma-Aldrich
磷酸铵 二元, reagent grade, ≥98.0%
Sigma-Aldrich
硫代硫酸钠 五水合物, ReagentPlus®, ≥99.5%
Sigma-Aldrich
硫代硫酸钠, ≥99.99% trace metals basis
Sigma-Aldrich
磷酸铵 二元, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98% (alkalimetric)
Sigma-Aldrich
氢氧化铵 溶液, puriss., meets analytical specification of Ph. Eur., 25-30% NH3 basis
Sigma-Aldrich
磷酸一铵, 99.999% trace metals basis
Sigma-Aldrich
硫代硫酸钠 溶液, 0.1 M
Sigma-Aldrich
氢氧化铵 溶液, puriss. p.a. plus, ≥25% NH3 in H2O
Sigma-Aldrich
磷酸铵 二元, ≥99.99% trace metals basis
Sigma-Aldrich
硫代硫酸钠 溶液, 0.01 M
Sigma-Aldrich
氢氧化铵 溶液, BioUltra, ~1 M NH3 in H2O (T)
Supelco
核黄素, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
硫代硫酸钠 五水合物, 99.999% trace metals basis
Sigma-Aldrich
硫代硫酸钠 溶液, 0.025 M
Sigma-Aldrich
磷酸二氢铵, suitable for plant cell culture
Sigma-Aldrich
硫代硫酸钠 五水合物, BioXtra, ≥99.5%
Sigma-Aldrich
磷酸铵 二元, BioUltra, ≥99.0% (T)
Sigma-Aldrich
磷酸二氢铵, BioUltra, ≥99.5% (T)