跳转至内容
Merck

20511

Supelco

进样口衬管,填充色谱柱,用于 Agilent®/HP 5700、5830/40A、5880A、5890A

pkg of 25 ea

登录查看公司和协议定价


About This Item

分類程式碼代碼:
41115719

包裝

pkg of 25 ea

技術

gas chromatography (GC): suitable

長度 × 外徑 × 內徑

91.5 mm × 3.0 mm × 1.8 mm

正在寻找类似产品? 访问 产品对比指南

一般說明

The liner is the second most important part of the inlet. It is the centrepiece of the inlet system, basically a glass tube between the septum and the column, where the sample is evaporated and brought into the gas phase. There are three most important parameters one should keep in mind while choosing a liner, firstly liner volume, considering a typical liner has a volume of 900μl, secondly liner treatment, one should always use a deactivated liner, so that the glass does not react with the analytes introduced in the liner, thirdly liner design, different designs are available like straight, tapered, baffled and without glass wool and one should be careful enough while choosing the design such that it is compatible with the desired injection mode.
Deactivated (silanized) glass inlet liner for packed injection ports.
  • Fits Agilent (5890, 6890, and 7890)

應用

Inlet liner maybe used for the determination and evaluation of volatile components in food products. The vegetable oil maybe directly placed into the GC inlet liner packed with glass wool and then inserted into the heated inlet of the GC for analysis.

Choose from one of the most recent versions:

分析证书(COA)

Lot/Batch Number

Sorry, we don't have COAs for this product available online at this time.

If you need assistance, please contact 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Navneet Sharma et al.
Life sciences, 168, 65-76 (2016-11-20)
p-tertbutylcalix[4]arene loaded nanoemulsion has been designed, characterized and evaluated for skin decontamination of radionuclides of interest in nuclear and radiological emergencies. Further, nanoemulsion was evaluated for Ex-vivo complexation, skin permeation, interaction and cytodermal toxicity. Ex-vivo skin complexation studies were conducted
Fire Debris Analysis.
Stauffer E
Science, 249-253 (2007)
Analysis of vegetable oils for flavor quality by direct gas chromatography.
Dupuy HP
Journal of the American Oil Chemists' Society, 54 (10), 445-449 (1977)
Julie Carnesecchi et al.
PloS one, 10(3), e0120672-e0120672 (2015-03-18)
The post-menopausal decrease in estrogen circulating levels results in rapid skin deterioration pointing out to a protective effect exerted by these hormones. The identity of the skin cell type responding to estrogens is unclear as are the cellular and molecular

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门