跳转至内容
Merck

52944

Sigma-Aldrich

Anti-Rabbit IgG−Abberior® STAR 488 antibody produced in goat

for STED application

别名:

Abberior® STAR 488-Anti-Rabbit IgG antibody produced in goat

登录查看公司和协议定价


About This Item

分類程式碼代碼:
12352200
NACRES:
NA.32

生物源

goat

品質等級

抗體表格

affinity isolated antibody

抗體產品種類

secondary antibodies

無性繁殖

polyclonal

形狀

buffered aqueous solution

物種活性

rabbit

存貨情形

available only in USA and Canada

濃度

~1 mg/mL

螢光

λex 503 nm; λem 524 nm in PBS, pH 7.4

儲存溫度

−20°C

一般說明

Abberior STAR 488 was developed for STED and confocal microscopy in the green spectral region. It is a bright green fluorescent dye. The dye works extremely well with Abberior Instruments Expert Line Microscopes and Leica STED microscopes. It can be very effectively excited with the prominent 488 nm laser line. For STED microscopy, Abberior STAR 488 can be efficiently used with STED Laser wavelengths between 590 - 610 nm. Abberior STAR 488 can substitute dyes like Oregon Green 488, Atto 488 or Alexa Fluor 488. Abberior STAR 488 is the ideal partner for Abberior STAR 440SXP to obtain optimal 2 Color STED results. Best results are obtained with freshly prepared samples.

Photophysical properties (carboxylic acid):
Absorption Maximum, λex [nm]: 503 (PBS pH 7.4), 504 (H2O), 507 (MeOH + 0.1% TFA)
Extinction Coefficient, εmax [M-1cm-1]: 65 000 (PBS pH 7.4), 80 000 (H2O), 85 000 (MeOH + 0.1% TFA)
Correction Factor, CF260 = ε260max: 0,28 (PBS pH 7.4)
Correction Factor, CF280 = ε280max: 0,14 (PBS pH 7.4)
Fluorescence Maximum, λem [nm]: 524 (PBS pH 7.4), 525 (H2O), 531 (MeOH + 0.1% TFA)
Recommended STED Wavelength, λ [nm]: 590 - 610
Fluorescence Quantum Yield, λ: 0,89 (PBS pH 7.4)
Fluorescence Lifetime, τ [ns]: 3,9 (PBS pH 7.4)

應用

Anti-Rabbit IgG-Abberior® STAR 488 antibody has been used as a secondary antibody:
  • for fluorescent immunohistochemistry in prostate cancer cell lines, PPC-1 and TSU-Pr1
  • for immunofluorescence in HeLa and monkey kidney COS-7 cells
  • for STED (stimulated emission depletion) microscopy in OLN-t40-α-syn cells (oligodendroglial cells)

適合性

Designed and tested for fluorescent super-resolution microscopy

分析報告

May contain significant amounts of BSA as stabilizer
unconjugated dye ≤5% of total fluorescence

法律資訊

ALEXA FLUOR is a trademark of Life Technologies
Atto is a trademark of Atto-Tec GmbH
abberior is a registered trademark of Abberior GmbH

未找到合适的产品?  

试试我们的产品选型工具.

儲存類別代碼

12 - Non Combustible Liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Katharina Pukaß et al.
Frontiers in cellular neuroscience, 9, 163-163 (2015-05-23)
α-Synuclein (α-syn) positive glial cytoplasmic inclusions (GCI) originating in oligodendrocytes (ODC) are a characteristic hallmark in multiple system atrophy (MSA). Their occurrence may be linked to a failure of the ubiquitin proteasome system (UPS) or the autophagic pathway. For proteasomal
Giuseppe Vicidomini et al.
Methods (San Diego, Calif.), 66(2), 124-130 (2013-07-03)
Stimulation emission depletion (STED) microscopy breaks the spatial resolution limit of conventional light microscopy while retaining its major advantages, such as working under physiological conditions. These properties make STED microscopy a perfect tool for investigating dynamic sub-cellular processes in living
Combination of axitinib and dasatinib for anti-cancer activities in two prostate cancer cell lines.
Peng N
Bangladesh Journal of Pharmacology, 11, 10-10 (2016)
Tim Grotjohann et al.
Nature, 478(7368), 204-208 (2011-09-13)
Lens-based optical microscopy failed to discern fluorescent features closer than 200 nm for decades, but the recent breaking of the diffraction resolution barrier by sequentially switching the fluorescence capability of adjacent features on and off is making nanoscale imaging routine. Reported
T A Klar et al.
Optics letters, 24(14), 954-956 (2007-12-13)
We overcame the resolution limit of scanning far-field fluorescence microscopy by disabling the fluorescence from the outer part of the focal spot. Whereas a near-UV pulse generates a diffraction-limited distribution of excited molecules, a spatially offset pulse quenches the excited

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门