生物源
goat
品質等級
抗體表格
affinity isolated antibody
抗體產品種類
secondary antibodies
無性繁殖
polyclonal
形狀
buffered aqueous solution
物種活性
rabbit
存貨情形
available only in USA and Canada
濃度
~1 mg/mL
螢光
λex 503 nm; λem 524 nm in PBS, pH 7.4
儲存溫度
−20°C
一般說明
Abberior STAR 488 was developed for STED and confocal microscopy in the green spectral region. It is a bright green fluorescent dye. The dye works extremely well with Abberior Instruments Expert Line Microscopes and Leica STED microscopes. It can be very effectively excited with the prominent 488 nm laser line. For STED microscopy, Abberior STAR 488 can be efficiently used with STED Laser wavelengths between 590 - 610 nm. Abberior STAR 488 can substitute dyes like Oregon Green 488, Atto™ 488 or Alexa Fluor™ 488. Abberior STAR 488 is the ideal partner for Abberior STAR 440SXP to obtain optimal 2 Color STED results. Best results are obtained with freshly prepared samples.
Photophysical properties (carboxylic acid):
Absorption Maximum, λex [nm]: 503 (PBS pH 7.4), 504 (H2O), 507 (MeOH + 0.1% TFA)
Extinction Coefficient, εmax [M-1cm-1]: 65 000 (PBS pH 7.4), 80 000 (H2O), 85 000 (MeOH + 0.1% TFA)
Correction Factor, CF260 = ε260/εmax: 0,28 (PBS pH 7.4)
Correction Factor, CF280 = ε280/εmax: 0,14 (PBS pH 7.4)
Fluorescence Maximum, λem [nm]: 524 (PBS pH 7.4), 525 (H2O), 531 (MeOH + 0.1% TFA)
Recommended STED Wavelength, λ [nm]: 590 - 610
Fluorescence Quantum Yield, λ: 0,89 (PBS pH 7.4)
Fluorescence Lifetime, τ [ns]: 3,9 (PBS pH 7.4)
Photophysical properties (carboxylic acid):
Absorption Maximum, λex [nm]: 503 (PBS pH 7.4), 504 (H2O), 507 (MeOH + 0.1% TFA)
Extinction Coefficient, εmax [M-1cm-1]: 65 000 (PBS pH 7.4), 80 000 (H2O), 85 000 (MeOH + 0.1% TFA)
Correction Factor, CF260 = ε260/εmax: 0,28 (PBS pH 7.4)
Correction Factor, CF280 = ε280/εmax: 0,14 (PBS pH 7.4)
Fluorescence Maximum, λem [nm]: 524 (PBS pH 7.4), 525 (H2O), 531 (MeOH + 0.1% TFA)
Recommended STED Wavelength, λ [nm]: 590 - 610
Fluorescence Quantum Yield, λ: 0,89 (PBS pH 7.4)
Fluorescence Lifetime, τ [ns]: 3,9 (PBS pH 7.4)
應用
Anti-Rabbit IgG-Abberior® STAR 488 antibody has been used as a secondary antibody:
- for fluorescent immunohistochemistry in prostate cancer cell lines, PPC-1 and TSU-Pr1
- for immunofluorescence in HeLa and monkey kidney COS-7 cells
- for STED (stimulated emission depletion) microscopy in OLN-t40-α-syn cells (oligodendroglial cells)
適合性
Designed and tested for fluorescent super-resolution microscopy
分析報告
May contain significant amounts of BSA as stabilizer
unconjugated dye ≤5% of total fluorescence
unconjugated dye ≤5% of total fluorescence
法律資訊
ALEXA FLUOR is a trademark of Life Technologies
Atto is a trademark of Atto-Tec GmbH
abberior is a registered trademark of Abberior GmbH
未找到合适的产品?
试试我们的产品选型工具.
儲存類別代碼
12 - Non Combustible Liquids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
Frontiers in cellular neuroscience, 9, 163-163 (2015-05-23)
α-Synuclein (α-syn) positive glial cytoplasmic inclusions (GCI) originating in oligodendrocytes (ODC) are a characteristic hallmark in multiple system atrophy (MSA). Their occurrence may be linked to a failure of the ubiquitin proteasome system (UPS) or the autophagic pathway. For proteasomal
Methods (San Diego, Calif.), 66(2), 124-130 (2013-07-03)
Stimulation emission depletion (STED) microscopy breaks the spatial resolution limit of conventional light microscopy while retaining its major advantages, such as working under physiological conditions. These properties make STED microscopy a perfect tool for investigating dynamic sub-cellular processes in living
Combination of axitinib and dasatinib for anti-cancer activities in two prostate cancer cell lines.
Bangladesh Journal of Pharmacology, 11, 10-10 (2016)
Nature, 478(7368), 204-208 (2011-09-13)
Lens-based optical microscopy failed to discern fluorescent features closer than 200 nm for decades, but the recent breaking of the diffraction resolution barrier by sequentially switching the fluorescence capability of adjacent features on and off is making nanoscale imaging routine. Reported
Optics letters, 24(14), 954-956 (2007-12-13)
We overcame the resolution limit of scanning far-field fluorescence microscopy by disabling the fluorescence from the outer part of the focal spot. Whereas a near-UV pulse generates a diffraction-limited distribution of excited molecules, a spatially offset pulse quenches the excited
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门