推荐产品
等級
JIS special grade
蒸汽密度
2.6 (vs air)
蒸汽壓力
12.5 mmHg ( 20 °C)
化驗
≥99.0%
形狀
liquid
expl. lim.
9.8 %
存貨情形
available only in Japan
折射率
n20/D 1.397 (lit.)
bp
98 °C (lit.)
mp
−115 °C (lit.)
密度
0.808 g/mL at 25 °C (lit.)
SMILES 字串
CCC(C)O
InChI
1S/C4H10O/c1-3-4(2)5/h4-5H,3H2,1-2H3
InChI 密鑰
BTANRVKWQNVYAZ-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
應用
产品编号
说明
价格
訊號詞
Warning
危險分類
Eye Irrit. 2 - Flam. Liq. 3 - STOT SE 3
標靶器官
Central nervous system, Respiratory system
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 1
閃點(°F)
75.2 °F
閃點(°C)
24 °C
Stefan Hofbauer et al.
Archives of biochemistry and biophysics, 574, 36-48 (2015-01-21)
Chlorite dismutase-like proteins are structurally closely related to functional chlorite dismutases which are heme b-dependent oxidoreductases capable of reducing chlorite to chloride with simultaneous production of dioxygen. Chlorite dismutase-like proteins are incapable of performing this reaction and their biological role
Prabha Dwivedi et al.
Analytical chemistry, 78(24), 8200-8206 (2006-12-15)
This article introduces the concept of chiral ion mobility spectrometry (CIMS) and presents examples demonstrating the gas-phase separation of enantiomers of a wide range of racemates including pharmaceuticals, amino acids, and carbohydrates. CIMS is similar to traditional ion mobility spectrometry
H Yasui et al.
Bulletin of entomological research, 102(2), 157-164 (2011-09-29)
A serious sugarcane pest, Dasylepida ishigakiensis, remains in the soil during most of its life cycle except for a short period for mating. Mating disruption by an artificial release of the sex pheromone (R)-2-butanol (R2B), therefore, may be a feasible
R A Rosenberg et al.
Physical review letters, 101(17), 178301-178301 (2008-11-13)
We demonstrate for the first time that low-energy spin-polarized secondary electrons, produced by irradiation of a magnetic substrate, can induce chiral-selective chemistry. Our approach was to perform detailed measurements of the reaction rate for x-ray induced, secondary electron photolysis of
Feng Gao et al.
Journal of the American Chemical Society, 129(49), 15240-15249 (2007-11-16)
The enantioselective chemisorption of R- and S-propylene oxide has been measured either on clean Pd(111) that has been exposed to S-2-butanol at various temperatures to vary the proportion of 2-butanol and 2-butoxide species or by adsorbing S-2-butanol on oxygen-covered Pd(111)
Chromatograms
suitable for GCsuitable for GCsuitable for GC我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门