产品名称
Millipore Express PHF 筒式过滤器 30 in.0.2 µm 7 号氟碳橡胶, pore size 0.2 μm, cartridge nominal length 30 in. (75 cm), Code 7, fluoroelastomer seal
材料
fluoroelastomer seal
polyethersulfone
polypropylene
polypropylene support
polysulfone
品質等級
法律遵循
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
無菌
non-sterile
滅菌相容性
autoclavable compatible
steam-in-place compatible
產品線
Millipore Express®
特點
hydrophilic
製造商/商標名
Millipore Express®
參數
≤90 mL/min air diffusion at 2.76 bar (40 psig) and 23 °C (in water)
0.07 bar max. differential pressure (1 psid) at 135 °C (Reverse)
0.35 bar max. differential pressure (5 psid) at 135 °C (Forward)
1.0 psi max. differential pressure (69 mbar) at 135 °C (Reverse)
1.4 bar max. differential pressure (20 psid) at 25 °C (Reverse)
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
20 psi max. differential pressure (1.4 bar) at 25 °C (Reverse)
25 psi max. differential pressure (1.7 bar) at 80 °C (Forward)
5.0 psi max. differential pressure (340 mbar) at 135 °C (Forward)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
80 psi max. differential pressure (5.5 bar) at 25 °C (Forward)
技術
bioburden reduction: suitable
長度
30 in.
寬度
2.7 in.
柱標稱長度
30 in. (75 cm)
直徑
6.9 cm (2.7 in.)
過濾面積
1.62 m2
雜質
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
基質
Millipore Express® PHF
孔徑
0.2 μm pore size
輸入
sample type liquid
柱代碼
Code 7
一般說明
包裝
其他說明
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
- Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
準備報告
12 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 15 autoclave cycles of 60 min @ 126 °C
分析報告
Samples of membrane used in this filter were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 30 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
法律資訊
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门