跳转至内容
Merck
所有图片(1)

主要文件

03-0201-00

Millipore

SMC® Human IgE High Sensitivity Immunoassay Kit

登录查看公司和协议定价


About This Item

分類程式碼代碼:
12161503
eCl@ss:
32161000
NACRES:
NA.47

等級

for protein analysis

品質等級

描述

analytes available: IgE

特點

accuracy Minimum of 5 samples spiked with acceptable recovery between 86-89%.

物種活性

human

技術

single molecule counting: suitable

同型

IgE

一般說明

The SMC Human IgE High Sensitivity Immunoassay Kit contains all reagents required to perform the assays. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format. Assay protocols are similar to existing sandwich ELISA methods with two key differences: 1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification. 2) The SMC immunoassay system detects analytes using Single Molecule Counting (SMC) technology.
The Single Molecule Counting (TM=["SMC"]) Human IgE High Sensitivity Immunoassay uses a quantitative fluorescent sandwich immunoassay technique to measure IgE in human serum and plasma samples. The user coats a capture antibody specific for human IgE onto a 96-well microplate. After blocking the plate, the user pipettes standards and samples into the coated microplate wells. During incubation, the IgE present in the sample binds to the capture antibody on the coated plate. Unbound molecules are washed away during a wash step. The fluor-labeled detection antibody is added to each well and incubated. The detection antibody recognizes and binds to IgE that has been captured onto the plate, thus completing the immunosandwich. Following the final wash step, elution buffer is added and incubated. The elution buffer dissociates the bound protein sandwich from the plate surface, releasing the labeled antibodies. These antibodies are separated during transfer to a final microplate. The reading plate is loaded onto the Erenna or TM=["SMCxPRO"] System where the labeled molecules are detected and counted. The number of fluor-labeled detection antibodies counted is directly proportional to the amount of IgE present in the sample when captured. The amount of IgE in unknown samples is interpolated from a standard curve.

特異性

This assay does not show cross-reactivity against immunoglobulin subclasses IgA, IgD, IdE, IgG1, IgG2, IgG3, or IgG4 from in-house testing

成分

Assay Plate Coating Buffer Blocking Buffer Standard Diluent IgM Detection Antibody IgM Standard SMC® Human IgM Immunoassay Kit Instructions 10X Wash Buffer Buffer C Elution Buffer B Buffer 3 IgM Coating Antibody

分析報告

Minimum of 5 samples spiked and diluted (at least 3 dilutions) with acceptable recovery between 86-89%

法律資訊

SMC is a registered trademark of Singulex

免責聲明

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

象形圖

Skull and crossbonesHealth hazard

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B

儲存類別代碼

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

相关内容

See an overview of ultrasensitive immunoassay technology with Single Molecule Counting (SMC®) technology, including its workflow, biomarker detection platform, research areas, advantages of high sensitivity SMC® assays, and more.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门