Saltar al contenido
Merck
  • Simplified matrix solid phase dispersion procedure for the determination of parabens and benzophenone-ultraviolet filters in human placental tissue samples.

Simplified matrix solid phase dispersion procedure for the determination of parabens and benzophenone-ultraviolet filters in human placental tissue samples.

Journal of chromatography. A (2014-12-03)
F Vela-Soria, I Rodríguez, O Ballesteros, A Zafra-Gómez, L Ballesteros, R Cela, A Navalón
RESUMEN

In recent decades, the industrial development has resulted in the appearance of a large amount of new chemicals that are able to produce disorders in the human endocrine system. These substances, so-called endocrine disrupting chemicals (EDCs), include many families of compounds, such as parabens and benzophenone-UV filters. Taking into account the demonstrated biological activity of these compounds, it is necessary to develop new analytical procedures to assess the exposure in order to establish, in an accurate way, relationships between EDCs and harmful health effects in population. In the present work, a new method based on a simplified sample treatment by matrix solid phase dispersion (MSPD) followed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis, is validated for the determination of four parabens (methyl-, ethyl-, propyl- and butylparaben) and six benzophenone-UV filters (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8 and 4-hydroxybenzophenone) in human placental tissue samples. The extraction parameters were accurately optimized using multivariate optimization strategies. Ethylparaben ring-13C6 and benzophenone-d10 were used as surrogates. The found limits of quantification ranged from 0.2 to 0.4 ng g(-1) and inter-day variability (evaluated as relative standard deviation) ranged from 5.4% to 12.8%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 96% to 104%. The method was satisfactorily applied for the determination of compounds in human placental tissue samples collected at the moment of delivery from 10 randomly selected women.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Acetato de etilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetato de etilo, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Metanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetato de etilo, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Metanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Metanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Acetato de etilo, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Metanol, Absolute - Acetone free
Sigma-Aldrich
Metanol, anhydrous, 99.8%
Sigma-Aldrich
Metanol, BioReagent, ≥99.93%
Sigma-Aldrich
Metanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Acetato de etilo, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
Acetato de etilo, puriss., meets analytical specification of Ph. Eur., BP, NF, ≥99.5% (GC)
Sigma-Aldrich
Acetonitrilo, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Ethyl 4-hydroxybenzoate, ReagentPlus®, 99%
Sigma-Aldrich
Metanol, JIS special grade, ≥99.8%
Sigma-Aldrich
Metanol, ACS reagent, ≥99.8%
USP
Metanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetato de etilo, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrilo, biotech. grade, ≥99.93%
Sigma-Aldrich
Deuterium, 99.8 atom % D