Documentos clave

53829-U

Supelco

Ascentis® Express 90 Å C18 (2.7 μm) HPLC Columns

L × I.D. 15 cm × 4.6 mm, HPLC Column

Sinónimos:

Columna para HPLC C18 de tecnología Fused Core de núcleo cáscara (SPP)

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41115700
eCl@ss:
32110501
NACRES:
SB.52
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Nombre del producto

Columna para HPLC Ascentis® Express C18, 2,7 μm, 2.7 μm particle size, L × I.D. 15 cm × 4.6 mm

material

stainless steel column

Quality Level

agency

suitable for USP L1

product line

Ascentis®

feature

endcapped

manufacturer/tradename

Ascentis®

packaging

1 ea of

parameter

60 °C temp. range
600 bar max. pressure (9000 psi)

technique(s)

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable

L × I.D.

15 cm × 4.6 mm

surface area

135 m2/g

impurities

<5 ppm metals

matrix

Fused-Core particle platform
superficially porous particle

matrix active group

C18 (octadecyl) phase

particle size

2.7 μm

pore size

90 Å

operating pH

2-9

application(s)

food and beverages

separation technique

reversed phase

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

Las columnas de HPLC Ascentis Express, a través del uso de tecnología de partículas Fused-Core®, pueden proporcionarle la elevada velocidad y las elevadas eficiencias de las partículas inferiores a 2 μm a la vez que mantienen menores contrapresiones. La combinación de gran eficiencia y poca contrapresión beneficia a los usuarios de UPLC® (u otro sistema de presión ultraelevada), así como a los usuarios de la HPLC convencional.
Si desea más información sobre esta nueva tecnología de columna, visite la página de inicio Ascentis Express.

Legal Information

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Fused-Core is a registered trademark of Advanced Materials Technology, Inc.
UPLC is a registered trademark of Waters

Optional

Referencia del producto
Descripción
Precios

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Determination of the metabolite content of Brassica juncea cultivars by comprehensive two-dimensional liquid chromatography coupled to photodiode array and mass spectrometry detection
Arena K, et al.
Molecules (Basel), 25(5), 1235-1235 (2020)
Chemical characterization of three accessions of Brassica juncea L. extracts from different plant tissues
Oulad El Majdoub Y, et al.
Molecules (Basel), 25(22), 5421-5421 (2020)
Yong Foo Wong et al.
Electrophoresis (2018-02-08)
Metabolic profiling of Glycyrrhiza glabra using comprehensive two-dimensional liquid chromatography (LC × LC) coupled with photodiode array (PDA) and mass spectrometry (MS) detection is described. The separation was conducted under reversed-phase conditions, using a combination of first dimension (1 D) 150 mm microbore
Anna Różańska et al.
Foods (Basel, Switzerland), 9(8) (2020-08-23)
High quality extra virgin olive oils represent an optimal source of nutraceuticals. The European Union (EU) is the world's leading olive oil producer, with the Mediterranean region as the main contributor. This makes the EU the greatest exporter and consumer
Katia Arena et al.
Journal of separation science, 43(9-10), 1781-1789 (2020-04-03)
Olea europaea, meaning "European olive," is a small tree belonging to the family Oleaceae, occurring in the Mediterranean Basin. Olive oil is an essential component of a balanced diet because of its nutritional value. Among micronutrients, phenolic compounds did show important beneficial effects for human health.

Artículos

USP methods continuously revised for modernization and improved results in drug testing.

USP methods continuously revised for modernization and improved results in drug testing.

USP methods continuously revised for modernization and improved results in drug testing.

USP methods continuously revised for modernization and improved results in drug testing.

Ver todo

Protocolos

Lopinavir assay setup saves time and improves efficiency with shorter columns, meeting European pharmacopoeia guidelines.

Lopinavir assay setup saves time and improves efficiency with shorter columns, meeting European pharmacopoeia guidelines.

Chromatograms

application for HPLCapplication for HPLCapplication for HPLCapplication for HPLCMostrar más

Questions

1–10 of 14 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. can this column be used at higher pH (pH 9)?

    1 answer
    1. As noted in the 'PROPERTIES' section, this column has an operating pH of 2 - 9.

      Helpful?

  4. What is the part number for Phenomenex Kinetex C18 column with dimensions of 150mm (15cm) x 4.6mm ID x 2.6μm particle size?

    1 answer
    1. Unfortunately, we do not provide the Kinetex C18 column from Phenomenex. However, we offer our own alternative with similar characteristics, the Ascentis Express C18 column with a particle size of 2.7μm. The specific part number for this column is 538229-U. Please note that the minimal difference of 1μm in particle size should not significantly impact its performance.

      Helpful?

  5. What are the recommended long-term storage conditions for the Ascentis® Express C18, 2.7 μm HPLC Column?

    1 answer
    1. For long-term storage of silica-based, reversed-phase columns like the Ascentis® Express C18, 2.7 μm HPLC Column, it is recommended to store them in 100% acetonitrile. For shorter periods of storage (up to 3 or 4 days), it is generally safe to store the column in most common mobile phases. However, when using buffers, it is advised to protect both the column and the HPLC equipment by flushing the column with the mobile phase that does not contain the buffer. This can be accomplished by flushing the column with a mixture of the mobile phase without the buffer (e.g., when using 60/40 ACN/buffer, flush the column with 60/40 ACN/H2O). This flushing step helps eliminate any risk of corrosion from salts and ensures quick re-equilibration of the column with the original mobile phase. Additionally, before storing the column, it is important to tightly seal the end-fittings with the provided end plugs to prevent the packing material from drying out.

      Helpful?

  6. What flow rate should I use with Ascentis® Express HPLC Columns?

    1 answer
    1. Based on the minimum in the van Deemter curves, higher flows than 5um particle columns are required in order to maximize Ascentis Express column efficiency. The suggested starting point for flow rate for Ascentis Express columns: 1.6 mL/min for 4.6 mm ID;  0.8 mL/min for 3.0 mm ID; and 0.4mL/min for 2.1 mm ID.

      Helpful?

  7. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  8. Can I use Ascentis Express on any type of HPLC system?

    1 answer
    1. Ascentis Express HPLC columns are capable of use on standard HPLC systems as well as UHPLC systems.  Columns are packed in high pressure hardware capable of withstanding the pressures used in UHPLC systems.

      Helpful?

  9. What is the carbon load for Ascentis® Express C18 HPLC Columns?

    1 answer
    1. Carbon load which is commonly referred to as %Carbon is misleading and not meaningful for Ascentis® Express. Since Fused-Core™ particle is unique in the sense that it has a solid core and porous shell, the %Carbon number can not be compared to traditional porous particles.  The carbon coverage for Ascentis® Express C18 is 3.5 micromoles/meter-squared

      Helpful?

  10. How can I measure my instrument bandwidth (IBW) and determine what Ascentis® Express HPLC Columns can be used with minimal efficiency loss created by too much internal instrument volume?

    1 answer
    1. The Guide to Dispersion Measurement has simple instructions on how to measure IBW and can be found at sigma-aldrich.com/express.

      Helpful?

1–10 of 14 Questions  

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico