If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
MAK119
Acetylcholinesterase Activity Assay Kit
sufficient for 100 colorimetric tests
Sinónimos:
ACHE Activity Assay, RBC Cholinesterase Activity Assay
About This Item
Productos recomendados
uso
sufficient for 100 colorimetric tests
método de detección
colorimetric
enfermedades relevantes
neurological disorders
temp. de almacenamiento
room temp
Información sobre el gen
human ... ACHE(43)
mouse ... ACHE(11423)
Categorías relacionadas
Descripción general
Aplicación
Características y beneficios
Idoneidad
Principio
Código de clase de almacenamiento
10 - Combustible liquids
Clase de riesgo para el agua (WGK)
WGK 3
Elija entre una de las versiones más recientes:
Certificados de análisis (COA)
¿No ve la versión correcta?
Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
Can MAK119-1KT acetylcholinesteraseactivity kit used for plant samples also?
1 answer-
There is no information or data on this kit for usage with plant samples. However, there are no indications that it would not work with extracted plant samples with acetylcholinesterase activity within the range of 10 to 600 units per liter.
Helpful?
-
-
このキットはAChEに特異的に反応しますか? 血漿中のBuChEには反応しませんか?
1 answer-
This kit will detect acetylcholinesterase and butyrylcholinesterase and will not distinguish between the two.
Helpful?
-
-
Is it possible to dilute samples by 40x and extend the incubation time to accommodate those that fall below the linear range? Should we adhere to the 10-minute reaction time, or could we consider a longer incubation period to address issues associated with the yellow color continuing to develop when the plate is left out? This consideration arises from the need for a larger change in OD to accurately measure enzymatic activity, particularly due to issues with running out of the Assay Buffer for diluting samples by 40x.
1 answer-
It is recommended to keep the reaction time at 10 minutes, as the calibrator provided in the kit exhibits the same absorbance as 200 U/L acetylcholinesterase at 10 minutes and does not receive the working reagent. However, to increase the signal of the assay, the customer may increase the sample to working reagent volume. For instance, instead of adding 10 uL of sample to each well, add 20 uL of sample to each well. The plate should still be read at the 2 and 10 minute marks. Additionally, the supplier advises using EDTA as the anticoagulant.
Helpful?
-
-
Is the calibrator in this kit an acetylcholinesterase enzyme, or a colorimetric solution?
1 answer-
The calibrator is not the enzyme, it is a dye that, when used as directed in the protocol, has an absorbance equivalent to 200U/L under assay conditions.
Helpful?
-
-
Convert the AChE activity (units/L) into a units/mg of tissue value to represent the data?
1 answer-
To calculate the enzyme activity in U/mg, follow these steps:
AChE Activity = (A412 final – A412 initial) / (A412calibrator – A412 blank) × n × 200 × 0.0002 (U) Here, 0.0002 represents the volume (L) of the well. Specific Activity (U/mg) = AChE Activity (U) / tissue amount (mg)Helpful?
-
-
What is the difference between the two Acetylcholinesterase Activity Assay Kits MAK119 and CS0003?
1 answer-
Product CS0003 and MAK119 are produced by different manufacturers. In addition, CS0003 is sufficient for 200 tests while product MAK119 is sufficient for 100 tests. The principles and detection range are the same for both products.
The following is true for product CS0003:
- Direct procedure for measuring AChE levels in a variety of samples such as serum and plasma.
- Based on the Ellman method in which thiocholine, produced by AChE, reacts with 5,5'-dithiobis (2-nitrobenzoic acid) to form a colorimetric (412 nm) product, proportional to the AChE activity present.
- The AChE activity is measured without the use of a calibration curve. The AChE Positive Control in the kit can be used to screen for AChE inhibitors.
- This kit has a linear range of 10-600 units/liter of AChE activity.
The following is true for product MAK119:
- Direct assays of acetylcholinesterase activity in blood, serum, plasma, and other biological samples.
- Based on an improved Ellman method, in which thiocholine produced by the action of acetylcholinesterase forms a yellow color with 5,5’-dithiobis(2-nitrobenzoic acid). The intensity of the product color, measured at 412 nm, is proportionate to the enzyme activity in the sample.
- Detection range 10 to 600 U/L AChE activity in 96-well plate assay.Helpful?
-
-
Can I use this AChE kit to test inhibitory substances present in DMSO solution?
1 answer-
This kit is to measure ACheE activity in blood, serum and plasma samples. It has not been tested to measure AChE levels in a solution of DMSO. If you wanted to test the effects of DMSO present in your sample, you will need to assay a positive control sample alongside a positive control sample spiked with the suspected interfering substance (in this case, DMSO).
Bovine serum can be used as a positive control
Assay buffer can be used as a negative control.Standards can be varying concentrations of acetylcholinesterase within the linear detection range of the kit (10 to 600 U/L AChE activity); one possible source of acetylcholinesterase can be from Sigma Aldrich C3389 (Acetylcholinesterase from electric eel, link: https://www.sigmaaldrich.com/US/en/product/sigma/c3389
Helpful?
-