88144

Supelco

Tetratetracontane

analytical standard

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
CH3(CH2)42CH3
Número de CAS:
Peso molecular:
619.19
Beilstein/REAXYS Number:
1804576
EC Number:
MDL number:
UNSPSC Code:
41116107
PubChem Substance ID:
NACRES:
NA.24

grade

analytical standard

Quality Level

assay

≥98.0% (GC)

shelf life

limited shelf life, expiry date on the label

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

mp

85-87 °C (lit.)
85-88 °C

application(s)

petroleum

format

neat

SMILES string

CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC

InChI

1S/C44H90/c1-3-5-7-9-11-13-15-17-19-21-23-25-27-29-31-33-35-37-39-41-43-44-42-40-38-36-34-32-30-28-26-24-22-20-18-16-14-12-10-8-6-4-2/h3-44H2,1-2H3

InChI key

KMXFZRSJMDYPPG-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Categorías relacionadas

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

F Zemlin et al.
Science (New York, N.Y.), 229(4712), 461-462 (1985-08-02)
A liquid helium-cooled cryoelectron microscope, operated to expose the specimen to only a very low electron dose, was used to obtain structural images of monolamellar n-tetratetracontane (n-C44H90) crystals at 0.25-nanometer resolution. These results are in contrast to earlier predictions that
R M Glaeser et al.
Ultramicroscopy, 111(2), 90-100 (2010-12-28)
Quantitative analysis of electron microscope images of organic and biological two-dimensional crystals has previously shown that the absolute contrast reached only a fraction of that expected theoretically from the electron diffraction amplitudes. The accepted explanation for this is that irradiation
Martin Göllner et al.
Advanced materials (Deerfield Beach, Fla.), 22(39), 4350-4354 (2010-08-25)
The encapsulation of pentacene thin-film transistors (TFTs) by a 50 nm thick layer of a long chain alkane (C₄₄H₉₀) enables the operation in an aqueous solution of 1 mM NaCl. It is the first time that pentacene TFTs operate successfully

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico