Accéder au contenu
Merck
  • Abortion after deliberate Arthrotec® addition to food. Mass spectrometric detection of diclofenac, misoprostol acid, and their urinary metabolites.

Abortion after deliberate Arthrotec® addition to food. Mass spectrometric detection of diclofenac, misoprostol acid, and their urinary metabolites.

International journal of legal medicine (2014-12-20)
Bernhard Watzer, Klaas J Lusthof, Horst Schweer
RÉSUMÉ

Arthrotec(®) (AT) is a combination of diclofenac, a nonsteroidal anti-inflammatory drug (NSAID), and misoprostol (MP), a synthetic analogue of prostaglandin E1 (PGE1). MP is a lipophilic methyl ester prodrug. It is readily metabolized to the biologically active misoprostol acid (MPA). During the last few years, medical studies exhibited MP to be an excellent abortive. In this paper, we describe a rare criminal case of MP abortion, initiated by the expectant father. After the abortion, samples of vomit and urine were collected. Systemic exposure to MP is difficult to prove, because both MP and the active metabolite MPA are hardly excreted in urine. Therefore, in addition to routine toxicological analysis, we used slightly modified, well-established liquid and gas chromatographic/tandem mass spectrometric (LC/MS/MS and GC/MS/MS) methods, for the direct and the indirect detection of MPA and its metabolites. In this case, we were able to demonstrate the presence of the major MP metabolites 2,3-dinor-MPA and 2,3,4,5-tetranor-MPA in the urine of the victim. We also detected paracetamol, 3-methoxyparacetamol and diclofenac-glucuronide in the urine. In the vomit of the victim, we detected diclofenac and MPA. These results, combined with the criminal investigations, showed that the accused had mixed MP into the food of his pregnant girlfriend. Finally, these investigations contributed to a confession of the accused.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acide phosphorique, 85 wt. % in H2O, 99.99% trace metals basis
Supelco
N,O-Bis(triméthylsilyl)trifluoroacétamide avec triméthylchlorosilane, with 1% trimethylchlorosilane, for GC derivatization, LiChropur
Sigma-Aldrich
Acide phosphorique, crystalline, ≥99.999% trace metals basis
Sigma-Aldrich
Alcool isopropylique, ≥99.7%, FCC, FG
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
2-Propanol, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
N,O-Bis(triméthylsilyl)trifluoroacétamide, ≥99%
Sigma-Aldrich
Acide phosphorique, 85 wt. % in H2O, FCC, FG
Sigma-Aldrich
2-Propanol, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
2-Propanol, for molecular biology, BioReagent, ≥99.5%
Sigma-Aldrich
Acide phosphorique, BioUltra, ≥85% (T)
Sigma-Aldrich
Méthanol, anhydrous, 99.8%
Sigma-Aldrich
Hydroxylamine hydrochloride, 99.999% trace metals basis
Sigma-Aldrich
N,N-Diisopropyléthylamine, ReagentPlus®, ≥99%
Sigma-Aldrich
2-Propanol, anhydrous, 99.5%
Sigma-Aldrich
Propylene glycol monomethyl ether acetate, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Acide formique, ≥95%, FCC, FG
Sigma-Aldrich
Acide phosphorique, ≥85 wt. % in H2O, ≥99.999% trace metals basis
Sigma-Aldrich
Acétone, natural, ≥97%
Sigma-Aldrich
N,N-Diisopropyléthylamine, purified by redistillation, 99.5%
Sigma-Aldrich
Hydroxylamine hydrochloride, 99.995% trace metals basis
Sigma-Aldrich
Acide phosphorique, BioReagent, suitable for insect cell culture, 85%
Sigma-Aldrich
Acétone, ≥99%, meets FCC analytical specifications
Sigma-Aldrich
Acétonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Trifluoroacetamide, 97%
Supelco
Oxazepam-d5 solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Acide phosphorique solution, NMR reference standard, 85% in D2O (99.9 atom % D), NMR tube size 4.2 mm × 8 in. , WGS-5BL Coaxial NMR tube
Sigma-Aldrich
Méthanol, NMR reference standard
Supelco
Oxazepam-d5 solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Diisopropyl ether, anhydrous, 99%, contains either BHT or hydroquinone as stabilizer