Accéder au contenu
Merck
  • Novel reverse-phase ion pair-high performance liquid chromatography separation of heparin, heparan sulfate and low molecular weight-heparins disaccharides and oligosaccharides.

Novel reverse-phase ion pair-high performance liquid chromatography separation of heparin, heparan sulfate and low molecular weight-heparins disaccharides and oligosaccharides.

Journal of chromatography. A (2013-03-05)
Fabio Galeotti, Nicola Volpi
RÉSUMÉ

In this study, by using tetrabutylammonium bisulfate as ion-pairing reagent, we were able to separate all the main heparin/heparan sulfate disaccharides generated by the action of heparinases along with the main Hep tetrasaccharide possessing a 3-O-sulfate group on the sulfoglucosamine unit and resistant to enzymatic action. Moreover, this novel HPLC method was able to separate and quantify uncommon disaccharides/oligosaccharides present in low molecular weight-heparins produced by chemical treatment with nitrous acid, dalteparin, or benzylation followed by alkaline hydrolysis, enoxaparin. Additionally, this procedure yields a sensitivity ∼4-times higher compared to conventional strong-anion exchange-HPLC separation. This was obtained by a common UV detector at 232 nm avoiding the use of complex procedures capable of increasing sensitivity by post-column derivatization. Finally, it is worth mentioning that disaccharide/oligosaccharide composition by HPLC and UV detection is a common analytical approach in quality control laboratories to evaluate heparins and low molecular weight-heparins structure and quality during their extraction and production. This simple HPLC approach offers high resolution and sensitivity for the rapid differentiation of pharmaceutical native heparins and derivatives and for the compositional analysis of small amounts of samples derived from biological sources at a glycosaminoglycans level of a few hundred nanogram.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Phosphate de tétrabutylammonium monobasique solution, 1.0 M in H2O
Sigma-Aldrich
Fluorure de tétrabutylammonium solution, 1.0 M in THF
Sigma-Aldrich
Tetrabutylammonium chloride, ≥97.0% (NT)
Sigma-Aldrich
Iodure de tétrabutylammonium, reagent grade, 98%
Sigma-Aldrich
Tetrabutylammonium perchlorate, ≥95.0% (T)
Sigma-Aldrich
Tetrabutylammonium cyanide, 95%
Sigma-Aldrich
Tetrabutylammonium bromide, ACS reagent, ≥98.0%
Sigma-Aldrich
Tetrabutylammonium hydroxide solution, 40 wt. % in H2O
Sigma-Aldrich
Tetrabutylammonium nitrate, 97%
Sigma-Aldrich
Tetrabutylammonium hydroxide solution, 1.0 M in methanol
Sigma-Aldrich
Tetrabutylammonium azide
Sigma-Aldrich
Iodure de tétrabutylammonium, ≥99.0% (AT)
Sigma-Aldrich
Tetrabutylammonium hydrogensulfate, 97%
Sigma-Aldrich
Fluorure de tétrabutylammonium solution, 75 wt. % in H2O
Supelco
Tetrabutylammonium hydroxide solution, ~40% in water, suitable for ion chromatography
Sigma-Aldrich
Bisulfate de tétrabutylammonium, puriss., ≥99.0% (T)
Sigma-Aldrich
Tetrabutylammonium bromide, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Phosphate de tétrabutylammonium monobasic, puriss., 99% (T)
Sigma-Aldrich
Tetrabutylammonium bromide solution, 50 wt. % in H2O
Supelco
Bisulfate de tétrabutylammonium, suitable for ion pair chromatography, LiChropur, ≥99.0%
Sigma-Aldrich
Tetrabutylammonium hydroxide solution, technical, ~40% in H2O (~1.5 M)
Supelco
Tetrabutylammonium perchlorate, for electrochemical analysis, ≥99.0%
Sigma-Aldrich
Tetrabutylammonium bisulfate solution, ~55% in H2O
Supelco
Tetrabutylammonium bromide, suitable for ion pair chromatography, LiChropur, ≥99.0%
Sigma-Aldrich
Tetrabutylammonium cyanide, technical, ≥80%
Sigma-Aldrich
Tetrabutylammonium hydroxide solution, 53.5-56.5% in H2O
Supelco
Tetrabutylammonium chloride, suitable for ion pair chromatography, LiChropur, ≥99.0%
Supelco
Iodure de tétrabutylammonium, suitable for ion pair chromatography, LiChropur, ≥99.0%
Supelco
Tetrabutylammonium bisulfate solution, suitable for ion pair chromatography, LiChropur, concentrate, ampule