46401-U
rac-β-Tocopherol solution
50 mg/mL in hexane, certified reference material
About This Item
Produits recommandés
Qualité
certified reference material
Niveau de qualité
CofA (certificat d'analyse)
current certificate can be downloaded
Conditionnement
ampule of 1 mL
Concentration
50 mg/mL in hexane
Technique(s)
HPLC: suitable
gas chromatography (GC): suitable
Application(s)
pharmaceutical (small molecule)
vitamins, nutraceuticals, and natural products
Format
single component solution
Température de stockage
-10 to -25°C
InChI
1S/C28H48O2/c1-20(2)11-8-12-21(3)13-9-14-22(4)15-10-17-28(7)18-16-25-24(6)26(29)19-23(5)27(25)30-28/h19-22,29H,8-18H2,1-7H3/t21?,22?,28-/m1/s1
Clé InChI
WGVKWNUPNGFDFJ-CBIUGAAKSA-N
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
Application
- Simultaneous determination of vitamin A and all four tocopherol isomers in human serum samples by ultra-high performance liquid chromatography (UHPLC) combined with fluorescence detection following their liquid-liquid extraction (LLE)
- Multi-residue analysis of vitamin B (B1, B2, B5, and B9), and vitamin E (α-tocopherol, β-tocopherol, α-tocotrienol, and β-tocotrienol) in grass and grain samples of four different wheat varieties by liquid chromatography electrospray ionization/multistage mass spectrometry (LC-ESI-MS/MS)
- Separation and estimation of four tocopherols and four tocotrienols in pecan nut cultivar samples using non-aqueous reversed-phase high-performance liquid chromatography (NARP-HPLC) coupled with atmospheric pressure chemical ionization-tandem mass spectrometric (APCI-MS/MS) detection
- Analysis of different cold pressed oil samples to detect and quantify eight tocol homologs using a chemometrically-assisted optimized high-performance liquid chromatography (HPLC) with fluorescence detection (FLD) based method
- Development and validation of normal-phase high-performance liquid chromatography (NP-HPLC) method, along with fluorescence detection, to simultaneously determine four tocopherols and four lignans in sesame oil samples
Autres remarques
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 Inhalation - STOT SE 3
Organes cibles
Central nervous system, Nervous system
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 3
Point d'éclair (°F)
-9.4 °F - closed cup
Point d'éclair (°C)
-23 °C - closed cup
Équipement de protection individuelle
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Faites votre choix parmi les versions les plus récentes :
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Protocoles
GB method with Ascentis® Express C30 column achieves baseline resolution for Vitamin A and E critical pair.
GB method with Ascentis® Express C30 column achieves baseline resolution for Vitamin A and E critical pair.
GB method with Ascentis® Express C30 column achieves baseline resolution for Vitamin A and E critical pair.
GB method with Ascentis® Express C30 column achieves baseline resolution for Vitamin A and E critical pair.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique