Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

EZBRAIN-SET

Millipore

Human Amyloid β40 and Amyloid β42 ELISA Kit

measures Amyloid β40 and Amyloid β42 in 50 μL tissue or cell lysate; combo pack

Synonyme(s) :

Amyloid β40/β42 ELISA, Brain ELISA Kit, Human Brain Amyloid ELISA

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
Nomenclature NACRES :
NA.84

product name

Human Amyloid β40 and Amyloid β42 Brain ELISA,

Espèces réactives

human

Niveau de qualité

Conditionnement

kit of 2 × 96 wells

Paramètres

50 μL sample volume (Overnight assay)

assay range

sensitivity: 6.0 pg/mL
(The lowest level of Amyloid β1-40 standard used in this assay ; 50 μL sample size)

sensitivity: 8 pg/mL
(The lowest level of Amyloid ß1-42 standard used in this assay; 50 μL sample size)

inter-assay cv: <10
intra-assay cv: <10
standard curve range: 16-500 pg/mL

Technique(s)

ELISA: suitable

Entrée

sample type tissue/cellular lysate

Application(s)

research use

Méthode de détection

colorimetric (450nm/590nm)

Conditions d'expédition

wet ice

Température de stockage

2-8°C

Informations sur le gène

human ... APP(351)

Spécificité

The Amyloid β40 ELISA uses monoclonal anti-Aβ antibodies with high selectivity for human Aβ. The capture antibody recognizes the C-terminal end of Amyloid β1-40, which causes a high selectivity for Aβ 40. The cross-reactivity of the used antibodies to other Amyloid peptides was tested by ELISA and BIACORE and shows no significant cross-reactivity to Aβ1-38, Aβ1-39, Aβ1-42, Aβ1-43 and Aβ1-44. The Amyloid β42 ELISA uses monoclonal anti-Aβ antibodies with high selectivity for human Aβ. The capture antibody recognizes the C-terminal end of Amyloid β1-42, which causes a high selectivity for Aβ42. The cross-reactivity of the used antibodies to other Amyloid peptides was tested by ELISA and BIACORE and shows no significant cross-reactivity to Aβ1-38, Aβ1-39, Aβ1-42, Aβ1-43 and Aβ1-44.


Used to detect/quantify: Amyloid β40 & Amyloid β42

Application

These assays require 50 µl of sample and are overnight assays.

Conditionnement

96-well plate

Stockage et stabilité

Components in the kit can be stored up to 2 weeks at 2-8°C

Autres remarques

Contact technical support for information

Clause de non-responsabilité

For research use only. Not for use in diagnostic procedures.

Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique