Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

72225

Sigma-Aldrich

Nickel(II) acetate tetrahydrate

purum p.a., ≥99.0% (KT)

Synonyme(s) :

Acetic acid nickel(II) salt

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
Ni(OCOCH3)2 · 4H2O
Numéro CAS:
Poids moléculaire :
248.84
Numéro Beilstein :
3730764
Numéro CE :
Numéro MDL:
Code UNSPSC :
12352302
ID de substance PubChem :
Nomenclature NACRES :
NA.23

Qualité

purum p.a.

Niveau de qualité

Pureté

≥99.0% (KT)

Forme

powder or crystals

Pertinence de la réaction

reagent type: catalyst
core: nickel

Densité

1.798 g/mL at 25 °C (lit.)

Traces d'anions

chloride (Cl-): ≤50 mg/kg

Traces de cations

Ca: ≤50 mg/kg
Cd: ≤50 mg/kg
Co: ≤1000 mg/kg
Cu: ≤50 mg/kg
Fe: ≤50 mg/kg
K: ≤100 mg/kg
Na: ≤1000 mg/kg
Pb: ≤50 mg/kg
Zn: ≤50 mg/kg

Application(s)

battery manufacturing

Chaîne SMILES 

[H]O[H].[H]O[H].[H]O[H].[H]O[H].CC(=O)O[Ni]OC(C)=O

InChI

1S/2C2H4O2.Ni.4H2O/c2*1-2(3)4;;;;;/h2*1H3,(H,3,4);;4*1H2/q;;+2;;;;/p-2

Clé InChI

OINIXPNQKAZCRL-UHFFFAOYSA-L

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Application

Used in synthesis of polynuclear-nickel polyoxotungstate cluster compounds that are ideal for the design of molecular magnets.

Pictogrammes

Health hazardExclamation markEnvironment

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 1A - Muta. 2 - Repr. 1B - Resp. Sens. 1 - Skin Sens. 1 - STOT RE 1

Code de la classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Elham S Aazam et al.
Bioorganic chemistry, 57, 5-12 (2014-08-28)
Transition metal complexes compounds with Schiff bases ligand representing an important class of compounds that could be used to develop new metal-based anticancer agents and as precursors of metal NPs. Herein, 2,3-bis-[(3-ethoxy-2-hydroxybenzylidene)amino]but-2-enedinitrile Schiff base ligand and its corresponding copper/nickel complexes
Rusi et al.
PloS one, 10(7), e0129780-e0129780 (2015-07-15)
The composite metal oxide electrode films were fabricated using ex situ electrodeposition method with further heating treatment at 300°C. The obtained composite metal oxide film had a spherical structure with mass loading from 0.13 to 0.21 mg cm(-2). The structure
Catherine F Wise et al.
Dalton transactions (Cambridge, England : 2003), 44(32), 14265-14271 (2015-07-22)
We report a nickel complex containing a conjugated bis-dithiocarbazate ligand that is an active catalyst for the reduction of protons into hydrogen gas. Light-driven hydrogen generation is observed from a system containing this molecular nickel catalyst coupled with a fluorescein
Raziyeh Akbarzadeh et al.
Dalton transactions (Cambridge, England : 2003), 43(44), 16745-16753 (2014-10-04)
A NiS2 nanostructure with a protective layer of Ni(2+) and SO4(2-) ions around it has been successfully synthesized using the Ni(II)-Salen (Salen = N,N'-bis(salicylidene)ethylenediamine) complex via a simple solvothermal approach in the presence of anhydrous sodium thiosulfate (Na2S2O3) as sulfur
Hui-Seon Kim et al.
The journal of physical chemistry letters, 6(22), 4633-4639 (2015-11-10)
Mismatch of current (I)-voltage (V) curves with respect to the scan direction, so-called I-V hysteresis, raises critical issue in MAPbI3 (MA = CH3NH3) perovskite solar cell. Although ferroelectric and ion migration have been proposed as a basis for the hysteresis

Articles

Lithium-ion batteries' characteristics make them popular for electricity storage due to portability, rechargeability, and low cost.

Lithium-ion batteries' characteristics make them popular for electricity storage due to portability, rechargeability, and low cost.

Lithium-ion batteries' characteristics make them popular for electricity storage due to portability, rechargeability, and low cost.

Lithium-ion batteries' characteristics make them popular for electricity storage due to portability, rechargeability, and low cost.

Afficher tout

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique