Accéder au contenu
Merck
Toutes les photos(4)

Key Documents

189456

Sigma-Aldrich

Poly(ethylene oxide)

average MV 900,000 (nominal), powder, hydroxyl, BHT as inhibitor

Synonyme(s) :

Polyethylene oxide, PEO

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
(-CH2CH2O-)n
Numéro CAS:
Numéro MDL:
Code UNSPSC :
12352104
ID de substance PubChem :
Nomenclature NACRES :
NA.23

product name

Poly(ethylene oxide), average Mv ~900,000 (nominal), powder

Forme

powder

Niveau de qualité

Poids mol.

average Mv ~900,000 (nominal)

Contient

200-500 ppm BHT as inhibitor

Viscosité

8,800-17,600 cP, 5 % in H2O(25 °C, Brookfield)(lit.)

Température de transition

Tm 65 °C

Densité

1.21 g/mL at 25 °C

Groupe fonctionnel

hydroxyl

Chaîne SMILES 

[H]OCCO

InChI

1S/C2H6O2/c3-1-2-4/h3-4H,1-2H2

Clé InChI

LYCAIKOWRPUZTN-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Poly(ethylene oxide) is a synthetic hydrophilicpolymer available in a number of molecular weights. It can be obtained by thering-opening polymerization of ethylene oxide. This biocompatible polymer can be widely used in the field of biomedical research,tissue engineering and surface functionalization.

Application

PEO can be used to prepare polymer electrolyte systems for energy storage and conversion devices due its low glass transition temperature and ability to form complex with many alkaline salts.

Owing to its hydration and swelling properties, it is widely used as a precursor to prepare block copolymer micelles for selective drug and gene delivery.

Itcan also be used to fabricate nanofibrous membranes for the adsorption of heavymetal ions.

Caractéristiques et avantages

  • Excellent polymer chain flexibility
  • Low toxicity
  • High solvation power
  • Lowglass transition temperature

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 1

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

Eyeshields, Gloves, type N95 (US)


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Daniel O'Brien et al.
Biomedical microdevices, 21(3), 53-53 (2019-06-17)
The biocompatible and biodegradable polymer poly(glycerol sebacate), or PGS, is a rubber-like material that finds use in several biomedical applications. PGS is often cast into a mold to form desired structures; alternatively, blending PGS with other reinforcing polymers produces viscous
Shih-Heng Chen et al.
International journal of molecular sciences, 20(7) (2019-04-04)
Peritendinous adhesion is a major complication after tendon injury and the subsequent repairs or reconstructions. The degree of adhesion can be reduced by the interposition of a membranous barrier between the traumatized tendon and the surrounding tissue. In the present
I L Konorova et al.
Patologicheskaia fiziologiia i eksperimental'naia terapiia, (4)(4), 7-9 (1991-07-01)
The search for antiaggregatory compounds is undertaken, as a rule, under in vitro conditions which do not reflect the dynamics of the real process. The present work deals with study of the peculiarities of the development of the collagen induced
P I Polimeni et al.
Journal of cardiovascular pharmacology, 14(3), 374-380 (1989-09-01)
The acute hemodynamic effects of an intravenously (i.v.) injected poly(ethylene oxide), Polyox WSR N-60K (dose 50 mg/kg), were studied in the open-chest rat anesthetized with sodium pentobarbital. The injectate is one of four drag-reducing polymers known to augment in vitro
D D Smyth et al.
Cardiovascular drugs and therapy, 4(1), 297-300 (1990-02-01)
Previous studies have demonstrated that Separan AP-30, a drag-reducing polymer, significantly decreased the formation of atherosclerotic plaques in rabbits fed a high-cholesterol diet. Furthermore, Separan AP-273, a polymer similar to but longer than Separan AP-30, markedly increased cardiac output in

Articles

Electrospinning technique applications discussed, emphasizing control of nanofibers and assembly into 3D architectures.

Electrospinning technique applications discussed, emphasizing control of nanofibers and assembly into 3D architectures.

Electrospinning technique applications discussed, emphasizing control of nanofibers and assembly into 3D architectures.

Electrospinning technique applications discussed, emphasizing control of nanofibers and assembly into 3D architectures.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique