Sigma-Aldrich

Hemoglobin Assay Kit

sufficient for 250 colorimetric tests

Synonyme(s) :

Hemoglobin Quantitation Kit

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
Nomenclature NACRES :
NA.84

Utilisation

sufficient for 250 colorimetric tests

Méthode de détection

colorimetric

Maladie(s) pertinente(s)

hematological disorder

Température de stockage

2-8°C

Informations sur le gène

Description générale

Hemoglobin (Hb) is an iron-containing metalloprotein that serves as the primary means of oxygen transport in vertebrates. Hemoglobin is primarily found in red blood cells where it makes up to 97% of the cell′s dry content. Hemoglobin can also be found in other tissues where it serves as an antioxidant. Alterations in blood hemoglobin levels occurs in many diseases such as anemia and polycytheima.

Application

Hemoglobin Assay Kit has been used to measure the concentration of hemoglobin.

Caractéristiques et avantages

Compatible with high-throughput handling systems. Can be adapted for use with cuvettes.

Adéquation

Suitable for the detection of hemoglobinin a variety of samples such as blood, serum, plasma, and urine. This kit can be used to study the effects of various compounds on hemoglobin metabolism and levels.

Principe

This assay is based on the improved Triton[NP1]/NaOH method in which hemoglobin is converted to a colorimetric product measured at 400 nm. This assay has a linear detection range between 0.9-200 mg/dL in the 96 well plate assay.

Informations légales

Triton is a trademark of The Dow Chemical Company or an affiliated company of Dow

Pictogrammes

CorrosionEnvironment

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Aquatic Acute 1 - Aquatic Chronic 2 - Eye Irrit. 2 - Met. Corr. 1

Code de la classe de stockage

8B - Non-combustible corrosive hazardous materials


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Malthe Hvas et al.
Conservation physiology, 5(1), cox066-cox066 (2017-12-09)
The parasitic amoeba Paramoeba perurans is an aetiological agent of amoebic gill disease (AGD), a serious problem in seawater salmonid aquaculture globally. Other finfish species are also infected and infection events may be associated with periods of unusual high temperatures.
Polycythemia vera masked due to severe iron deficiency anemia.
Kambali S and Asma T
Hematology/oncology and Stem Cell Therapy (2016)
M J Faulkner et al.
Journal of dairy science, 100(7), 5368-5377 (2017-05-01)
Eighteen multiparous cows were used in a split-plot replicated Latin square with two 28-d periods to evaluate the effects of source of supplemental Cu, Zn, and Mn (sulfates or hydroxy) on apparent absorption of minerals when fed in either a
Biochemical markers of oxidative stress in Saudi women with recurrent miscarriage.
Ghneim H K and Mashael M A
Journal of Korean Medical Science, 31(1), 98-105 (2016)
Benefits of fiber and antioxidant power of rice bran in Vitamin E deficient rats.
Carlos A G, et al.
Acta Bioquimica Clinica Latinoamericana, 51(1), 95-105 (2017)

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique