Accéder au contenu
Merck
Toutes les photos(2)

Principaux documents

MAK165

Sigma-Aldrich

Fluorimetric Hydrogen Peroxide Assay Kit

sufficient for 500 fluorometric tests (red fluorescence)

Synonyme(s) :

Hydrogen Peroxide Quantification Kit

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme

Sélectionner une taille de conditionnement

1 KIT
428,00 €

428,00 €


Disponible pour expédition le09 avril 2025Détails


Devis pour commande en gros

Sélectionner une taille de conditionnement

Changer de vue
1 KIT
428,00 €

About This Item

Code UNSPSC :
12161503
Nomenclature NACRES :
NA.84

428,00 €


Disponible pour expédition le09 avril 2025Détails


Devis pour commande en gros

Utilisation

sufficient for 500 fluorometric tests (red fluorescence)

Méthode de détection

fluorometric

Maladie(s) pertinente(s)

cardiovascular diseases; aging/geriatric diseases; orthopedic diseases; pulmonary disorders; neurological disorders

Température de stockage

−20°C

Catégories apparentées

Description générale

Hydrogen peroxide, a reactive oxygen species produced through the metabolism of molecular oxygen, serves as both an intracellular signaling messenger and a source of oxidative stress. Hydrogen peroxide is generated in cells via multiple mechanisms such as the NOX-mediated ROS production by neutrophils and macrophages (respiratory burst) or by the dismutase of superoxide anions produced as a result of electron leak during mitochondrial respiration. Abnormal hydrogen peroxide production contributes to oxidative cell damage and the progression of diseases such as asthma, atherosclerosis, osteoporosis, and neurodegeneration.

Caractéristiques et avantages

Compatible with high-throughput handling systems.

Adéquation

This kit is suitable to quantify hydrogen peroxide levels in a variety of samples such as cellular extracts and solutions.

Principe

The Fluorescent Hydrogen Peroxide Assay Kit provides a simple and reproducible method to quantify hydrogen peroxide levels in a variety of samples such as cellular extracts and solutions. This kit can also be used to detect hydrogen peroxide released from living cells or produced by oxidase activities. This kit utilizes a peroxidase substrate that generates a red fluorescent product (λex = 540/λem = 590 nm) after reaction with hydrogen peroxide that can be analyzed by a fluorescent microplate reader.

Pictogrammes

Health hazardExclamation mark

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Acute Tox. 4 Oral - Resp. Sens. 1

Code de la classe de stockage

10 - Combustible liquids

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Rakesh Ruchel Khanikar et al.
RSC advances, 12(15), 9466-9472 (2022-04-16)
Cold atmospheric pressure (CAP) plasma has a profound effect on protein-protein interactions. In this work, we have highlighted the deactivation of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) spike protein by CAP plasma treatment. Complete deactivation of spike protein
Gaëtan Caravello et al.
Frontiers in immunology, 13, 858360-858360 (2022-05-03)
Microsporidia are obligate intracellular parasites able to infest specifically a large range of species, including insects. The knowledge about the biology of microsporidial infections remains confined to mostly descriptive studies, including molecular approaches such as transcriptomics or proteomics. Thus, functional
Eda Gjika et al.
ACS applied materials & interfaces, 10(11), 9269-9279 (2018-02-24)
Cold atmospheric plasma (CAP), an ionized gas operated at near-ambient temperatures, has been introduced as a new therapeutic opportunity for treating cancers. The effectiveness of the therapy has been linked to CAP-generated reactive oxygen and nitrogen species such as hydrogen
Wei Zhu et al.
Oxidative medicine and cellular longevity, 2019, 5305014-5305014 (2019-06-11)
Females develop kidney stones less frequently than males do. However, it is unclear if this gender difference is related to altered estrogen/estrogen receptor (ER) signaling. Here, we found that ER beta (ERβ) signals could suppress hepatic oxalate biosynthesis via transcriptional
Yan Zhang et al.
Journal of nanobiotechnology, 19(1), 161-161 (2021-06-02)
As one typical cardiovascular disease, atherosclerosis severely endanger people' life and cause burden to people health and mentality. It has been extensively accepted that oxidative stress and inflammation closely correlate with the evolution of atherosclerotic plaques, and they directly participate

Questions

1–7 sur 7 questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 réponse
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Utile ?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 réponse
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Utile ?

  3. Can we use Assay buffer MAK165C included in the kit to lyse cells to make cellular extract to measure endogenous H2O2 level.

    1 réponse
    1. Yes, the Assay buffer that comes as one of the kit components (Product MAK165C) can be used to lyse cells. The kit provides 100 mL of Assay buffer, which is more than enough for the assays as well as to use some for sample preparation. MAK165C does not contain a surfactant, so the cells would need to be lysed by physical disruption...either sonication, or using a Dounce homogenizer (or equivalent).

      Utile ?

  4. What is the limit of detection for H2O2?

    1 réponse
    1. The lower limit of detection for kit MAK165 is 0.06 uM.

      Utile ?

  5. Does MAK165 recognize all oxidized products or specifically hydrogen peroxide?

    1 réponse
    1. MAK165 is used to quantify hydrogen peroxide in solutions and cell extracts. Therefore, the kit is specific for hydrogen peroxide and does not measure other oxidized products.

      Utile ?

  6. Are black plates with black bottoms suitable for use with the MAK165 kit, even though the Technical Bulletin recommends black plates with clear bottoms?

    1 réponse
    1. A solid black plate or a black wall with a clear bottom plate is suitable for use.

      Utile ?

  7. Is the red peroxidase substrate in kit MAK165 the chemical 10-acetyl-3,7-dihydroxyphenoxazine (also known as Amplex Red)?

    1 réponse
    1. The red peroxidase substrate in kit MAK165 is Amplex Red, which is the trademark of Invitrogen. The substrate is 10-Acetyl-3,7-dihydroxyphenoxazine and is chemically the same.

      Utile ?

Évaluations

Aucune valeur de notation

Filtres actifs

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique