21004

Supelco

Cesium iodide

analytical standard, suitable for mass spectrometry (MS)

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill) :
CsI
Numéro CAS:
Poids moléculaire :
259.81
Numéro CE :
Numéro MDL:
Code UNSPSC :
41116107
ID de substance PubChem :
Nomenclature NACRES :
NA.24
Le tarif et la disponibilité ne sont pas disponibles actuellement.

Niveau de qualité

Qualité

analytical standard

Essai

99.999%

Technique(s)

mass spectrometry (MS): suitable

Pf

626 °C (lit.)

Densité

4.51 g/mL at 25 °C (lit.)

Application(s)

cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care

Format

neat

Chaîne SMILES 

[I-].[Cs+]

InChI

1S/Cs.HI/h;1H/q+1;/p-1

Clé InChI

XQPRBTXUXXVTKB-UHFFFAOYSA-M

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Cesium iodide is a simple ionic salt. It has the capacity to undergo second order transformation from cubic B2 structure to body-centered tetragonal structure at low pressures. It is mostly used as input screens of X-ray image intensifiers.

Application

Cesium iodide has been used as calibration standard during native electrospray ionization time-of-flight mass spectrometry (ESI-TOF MS) analysis for measuring protein samples, from protein aggregates.
Suitable as standard for electrospray ionisation MS (ESI)[1][2]

Caractéristiques et avantages

Frequently used in devices such as phosphor screens for medical imaging, scintillators, calorimeters and a variety of particle detectors.

Pictogrammes

Health hazardEnvironment

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Aquatic Acute 1 - Repr. 2

Code de la classe de stockage

13 - Non Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

P Thibault et al.
Rapid communications in mass spectrometry : RCM, 5(10), 484-490 (1991-10-01)
The direct coupling of capillary electrophoresis (CE) and mass spectrometry, combined with ionspray ionization using a coaxial capillary arrangement, is described. The CE/mass spectrometer interface is shown to be effective for the analysis of native and tryptic peptides and of
Wei Zhao et al.
Medical physics, 31(9), 2594-2605 (2004-10-19)
Columnar structured cesium iodide (CsI) scintillators doped with Thallium (Tl) have been used extensively for indirect x-ray imaging detectors. The purpose of this paper is to develop a methodology for systematic investigation of the inherent imaging performance of CsI as
J.F. Anacleto et al.
Org. Mass Spectrom., 27, 660-660 (1992)
E Knittle et al.
Science (New York, N.Y.), 223(4631), 53-56 (1984-01-06)
Cesium iodide, a simple ionic salt at low pressures, undergoes a second-order transformation at 40 gigapascals (400 kilobars) from the cubic B2 (cesium chloride-type) structure to the body-centered tetragonal structure. Also, the energy gap between valence and conduction bands decreases
Yunjiao Zhou et al.
Cell reports, 34(5), 108699-108699 (2021-01-25)
Several potent neutralizing antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus have been identified. However, antibody-dependent enhancement (ADE) has not been comprehensively studied for SARS-CoV-2, and the relationship between enhancing versus neutralizing activities and antibody epitopes remains unknown.

Articles

MALDI-TOF MS is useful for monitoring complete conjugation.  Functionalized polymers are useful for creating polymer conjugates for diverse applications.

A RPLC-MS workflow for mass analysis of reduced monoclonal antibody, trastuzumab, including reduction procedures, calibration, and system suitability tests.

A RPLC-MS workflow for mass analysis of non-reduced monoclonal antibody, trastuzumab, including calibration, and system suitability tests.

Protocoles

SEC-MS protocol for rapid glycoprofiling of monoclonal antibodies with antibody purification and mass spectrometer calibration.

A complete workflow for the intact and middle-up mass analysis of reduced and non-reduced monoclonal antibodies based on SEC-MS with sample preparation by protein-A affinity clean-up.

Questions

Évaluations

Aucune valeur de notation

Filtres actifs

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique