C-051
Caffeine solution
1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Produits recommandés
Qualité
certified reference material
Niveau de qualité
Forme
liquid
Caractéristiques
SNAP-N-SPIKE®, SNAP-N-SHOOT®
Conditionnement
ampule of 1 mL
Fabricant/nom de marque
Cerilliant®
Concentration
1.0 mg/mL in methanol
Technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
Application(s)
forensics and toxicology
Format
single component solution
Température de stockage
−20°C
Chaîne SMILES
CN1C(=O)N(C)c2ncn(C)c2C1=O
InChI
1S/C8H10N4O2/c1-10-4-9-6-5(10)7(13)12(3)8(14)11(6)2/h4H,1-3H3
Clé InChI
RYYVLZVUVIJVGH-UHFFFAOYSA-N
Informations sur le gène
human ... ADORA1(134) , ADORA2A(135) , ADORA2B(136) , ADORA3(140)
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
Caffeine belongs to the class of active alkaloid compounds, mainly found in the leaves, fruits, and seeds of about 63 plant species. Coffee beans are the primary source of caffeine, in addition to tea leaves, chocolates, and energy drinks soft drinks. It is a central nervous system stimulant and acts by increasing alertness and reducing sleep.
Application
- To determine caffeine content in an aqueous solution of green coffee beans by two methods based on Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) and fluorescence spectrophotometry
- Extraction of caffeine by automated homogeneous liquid-liquid microextraction (A-HLLME) from five different beverage samples for its quantification by high-performance liquid chromatography combined with UV detection
- Simultaneous estimation of caffeine and chlorogenic acids in ground green coffee samples by a UV/Vis spectrometric method
- Multi-residue determination of caffeine and paracetamol by square-wave voltammetry using poly(4-amino-3-hydroxynaphthalene sulfonic acid)-modified glassy carbon electrode (poly(AHNSA)/GCE in coca-cola, pepsi, and tea samples
- Cyclic voltammetric and differential pulse voltammetric based detection and quantitative analysis of paracetamol, tryptophan, and caffeine, both separately and simultaneously, using an electrochemical sensor founded on tin sulfide (SnS)-titanium dioxide (TiO2)-graphene oxide (GO) composite modified glassy carbon electrode
Caractéristiques et avantages
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Informations légales
Produit(s) apparenté(s)
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 1
Point d'éclair (°F)
49.5 °F - closed cup
Point d'éclair (°C)
9.7 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".