Saltar al contenido
Merck

48486

Supelco

Vinyl acetate

analytical standard

Sinónimos:

Acetoxyethylene

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

1 G
150,00 €

150,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
1 G
150,00 €

About This Item

Fórmula lineal:
CH3CO2CH=CH2
Número de CAS:
Peso molecular:
86.09
Beilstein:
1209327
Número CE:
Número MDL:
Código UNSPSC:
12000000
ID de la sustancia en PubChem:

150,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

grado

analytical standard

Nivel de calidad

Agency

EPA 8240,8260

densidad de vapor

3 (vs air)

presión de vapor

88 mmHg ( 20 °C)

CofA

current certificate can be downloaded

temp. de autoignición

801 °F

lim. expl.

13.4 %

envase

pkg of 1000 mg

técnicas

HPLC: suitable
gas chromatography (GC): suitable

índice de refracción

n20/D 1.395 (lit.)

bp

72-73 °C (lit.)

mp

−93 °C (lit.)

densidad

0.934 g/mL at 25 °C (lit.)

aplicaciones

cleaning products
cosmetics
environmental
food and beverages
personal care
petroleum

Formato

neat

temp. de almacenamiento

2-8°C

cadena SMILES

CC(=O)OC=C

InChI

1S/C4H6O2/c1-3-6-4(2)5/h3H,1H2,2H3

Clave InChI

XTXRWKRVRITETP-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

This substance is listed on the positive list of the EU regulation 10/2011 for plastics intended to come into contact with food. Find all available reference materials for compounds listed in 10/2011 here
Vinyl acetate is an important ester of vinyl alcohol, which can find applications in the production of homo and copolymer dispersions.[1] The production of vinyl acetate involves the addition of acetic acid to acetylene in the gas phase in the presence of zinc acetate/charcoal as catalyst.[1]

Aplicación

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
Vinyl acetate may be used as an analytical reference standard for the quantification of the analyte in water samples using liquid chromatography technique.[2]

Otras notas

Acetato de Vinilo

Palabra de señalización

Danger

Frases de peligro

Clasificaciones de peligro

Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Carc. 2 - Flam. Liq. 2 - STOT SE 3

Órganos de actuación

Respiratory system

Código de clase de almacenamiento

3 - Flammable liquids

Clase de riesgo para el agua (WGK)

WGK 2

Punto de inflamabilidad (°F)

17.6 °F - closed cup

Punto de inflamabilidad (°C)

-8 °C - closed cup

Equipo de protección personal

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Weissermel K and Arpe H-J
Industrial Organic Chemistry (2003)
Determination of plastic monomers in water by solid-phase microextraction coupled with liquid chromatography
Batlle R, et al.
Journal of AOAC (Association of Official Analytical Chemists) International, 84(2), 431-436 (2001)
Francesca Reineri et al.
Nature communications, 6, 5858-5858 (2015-01-06)
The advent of nuclear spins hyperpolarization techniques represents a breakthrough in the field of medical diagnoses by magnetic resonance imaging. Dynamic nuclear polarization (DNP) is the most widely used method, and hyperpolarized metabolites such as [1-(13)C]-pyruvate are shown to report
María B Blanco et al.
Environmental science & technology, 46(16), 8817-8825 (2012-07-18)
The products formed from the reactions of OH radicals with vinyl acetate and allyl acetate have been studied in a 1080 L quartz-glass chamber in the presence and absence of NO(x) using in situ FTIR spectroscopy to monitor the reactant
Anna Piperno et al.
The Journal of organic chemistry, 75(9), 2798-2805 (2010-04-17)
A new template of C-4'-truncated phosphonated nucleosides (TPCOANs) has been obtained in good yields according to two different routes which exploit the reactivity of a phosphonated nitrone. The one-step procedure based on the 1,3-dipolar cycloaddition of a phosphonated nitrone with

Preguntas

1–2 de 2 Preguntas  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 respuesta
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      ¿Le ha resultado útil?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 respuesta
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      ¿Le ha resultado útil?

Revisiones

Sin puntuación

Filtros activos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico