Saltar al contenido
Merck

Saltar a

PKH26GL

PKH26 Red Fluorescent Cell Linker Kit for General Cell Membrane Labeling

Distributed for Phanos Technologies

Sinónimos:

Red PKH membrane dye

Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
Talla/SKUDisponibilidadPrecio
1 kit
Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad
1740,00 €

Acerca de este artículo

NACRES:
NA.32
UNSPSC Code:
12352207

1740,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

​
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


packaging

pkg of 1 kit

Quality Segment

manufacturer/tradename

Distributed for Phanos Technologies

storage condition

protect from light

technique(s)

live cell imaging : suitable

fluorescence

λex 551 nm; λem 567 nm (PKH26 dye)

detection method

fluorometric

shipped in

ambient

storage temp.

room temp

General description

PKH26 is a red‐fluorescent dye. This lipophilic membrane dye is widely used to determine cell proliferation in heterogeneous cells by flow cytometry.

Application

This kit is for general cell membrane labeling. It has been characterized in a number of model systems and has been found to be useful for in vitro cell labeling, in vitro proliferation studies and long term, in vivo cell tracking. The half-life for elution of PKH26 from labeled rabbit red blood cells is greater than 100 days. This enhanced stability is favorable for long term in vivo studies.
PKH26 Red Fluorescent Cell Linker Kit is for general cell membrane labeling. It has been characterized in a number of model systems and has been found to be useful for in vitro cell labeling, in vitro proliferation studies and long term, in vivo cell tracking. The half-life for elution of PKH26 from labeled rabbit red blood cells is greater than 100 days. This enhanced stability is favorable for long term in vivo studies.

Other Notes

For additional technical details on PKH and CellVue® Fluorescent Cell Linker Dyes including an extensive bibliography, please visit here.

Legal Information

CellVue is a registered trademark of Phanos Technologies

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
MINI26PKH26PCLPKH67GL
description

Distributed for Phanos Technologies

description

Distributed for Phanos Technologies

description

Distributed for Phanos Technologies

description

Distributed for Phanos Technologies

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

packaging

pkg of 1 kit

packaging

pkg of 1 kit

packaging

-

packaging

pkg of 1 kit

storage condition

protect from light

storage condition

protect from light

storage condition

-

storage condition

protect from light

detection method

fluorometric

detection method

fluorometric

detection method

-

detection method

fluorometric

shipped in

ambient

shipped in

ambient

shipped in

-

shipped in

ambient

manufacturer/tradename

Distributed for Phanos Technologies

manufacturer/tradename

Distributed for Phanos Technologies

manufacturer/tradename

-

manufacturer/tradename

-


Solo componentes del kit

Referencia del producto
Descripción

  • Diluent C 6 x 10

  • PKH26 Cell Linker in ethanol .5 mL

Pictogramas

FlameExclamation mark

Palabra de advertencia

Danger

Códigos de peligro

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 2

Clase de almacenamiento

3 - Flammable liquids

¿Qué está pasando?

WGK 1

Punto de inflamación (°F)

57.2 °F - closed cup

Punto de inflamación (°C)

14.0 °C - closed cup



Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos



Preguntas

1–10 de 11 Preguntas  
  1. Can we stain extracellular vesicles particularly exosomes (isolated and suspended in PBS) we have used exosome isolation kit , is ultracentrifugation step must at the end, as for now we are not using ultracentifuge

    1 respuesta
    1. PKH dyes have been successfully used to label exosomes and extracellular vesicles for in vitro and in vivo tracking experiments. The exosome labeling protocol below details steps for reliable fluorescent labeling of exosomes using PKH dyes for micro vesicle tracking experiments. Instead of PBS, use the kit’s recommended Diluent C for optimal dye performance. Final resuspension in PBS is acceptable for downstream applications.

      Please check this link for more details:
      https://www.sigmaaldrich.com/technical-documents/protocols/biology/cell-culture/exosome-labeling-pkh.html

      These links could also be helpful to you:
      https://www.sigmaaldrich.com/catalog/product/sigma/mini26?lang=en&region=US
      https://www.sigmaaldrich.com/technical-documents/articles/biowire/cell-tracking-lipophilic-membrane-dyes.html

      ¿Le ha resultado útil?

  2. If we want to use the PKH to label the membrane of fibroblast, and then co-culture them with tumor cells in order to interact, ¿ Will PKH transfer from fibroblast to tumor cells?

    1 respuesta
    1. PKH dyes are routinely used in co-culture situations. Because staining is nearly instantaneous, rapid and homogeneous dispersion of cells in dye solution is essential. There should be no excess or unincorporated dye in the medium prior to mixing or co-culturing the cell lines. Free dye will be taken up by all cells. See the links below to the product protocol as well as two additional co-culture studies using PKH dyes:

      Protocol
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/271/475/mini26bul.pdf

      Co-culture in scaffolds
      https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5155425/

      Co-culture, mixed monolayer, and on Transwell
      https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5168417/

      ¿Le ha resultado útil?

  3. What is the difference between PKH26 Red Fluorescent Cell Linker Kit for Phagocytic Cell Labeling Products PKH26GL and PKH26PCL?

    1 respuesta
    1. The general labeling kit (Product No. PKH26GL) will label the membrane of the cells.  For phagocytic cells, Product No. PKH26PCL is used.  This kit utilizes dye aggregates for specific labeling of phagocytic cells in the presence of other cell types.

      ¿Le ha resultado útil?

  4. Will Product PKH26GL, PKH26 Red Fluorescent Cell Linker Kit for Phagocytic Cell Labeling Products, stain dead cells?

    1 respuesta
    1. As long as the cell has an intact membrane, the PKH26 dye can label the cell.

      ¿Le ha resultado útil?

  5. Product PKH26GL, PKH26 Red Fluorescent Cell Linker Kit for General Cell Membrane Labeling, is a red dye.  Do you offer a kit that stains the cells green?

    1 respuesta
    1. We offer Product numbers:PKH2GL Both of these kits stain the cells with a dye that emits in the green fluorescent range.

      ¿Le ha resultado útil?

  6. Does the dye leak from the cells after labeling when using Product PKH67GL, PKH67 Green Fluorescent Cell Linker Kit for General Cell Membrane Labeling?

    1 respuesta
    1. In general, slow loss of fluorescence has been observed with PKH1 and PKH2 in in vivo studies and it is likely that PKH67 may also slowly lose fluorescence. Leakage (or loss of staining intensity) may also occur due to cell-to-cell transfer of the dye. The most common cause of cell-to-cell dye transfer is inadequate washing of the cells. Wash cells 3-5 times after labeling and transfer samples to new tubes between washes.

      ¿Le ha resultado útil?

  7. Are cells lost during the PKH67 Green Fluorescent Cell Linker Kit for General Cell Membrane Labeling staining process?

    1 respuesta
    1. Over-labeling of the cells will result in loss of membrane integrity and reduced cell recovery.  Methods for improving cell viability can be found on the troubleshooting guide.

      ¿Le ha resultado útil?

  8. What is the Department of Transportation shipping information for this product?

    1 respuesta
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      ¿Le ha resultado útil?

  9. When using Product PKH67GL, PKH67 Green Fluorescent Cell Linker Kit for General Cell Membrane Labeling, how long will the cells remain stained after treatment?

    1 respuesta
    1. Labeled cells that have been washed can be visualized in culture up to 100 days after staining (for non-dividing cells). The dye itself is stable and will divide equally when the cells divide. After staining with PKH dyes, you can observe as many as 8 divisions depending on how brightly the cells were stained initially and the amount of surface area on the cells. Most commonly, 4-6 divisions can be visualized.

      ¿Le ha resultado útil?

  10. What method of fixation can be used for tissue/cells with the PKH Fluorescent Cell Linker Kit for General Cell Membrane Labeling dyes?

    1 respuesta
    1. A protocol for visualization of tissue sections can be found in the technical bulletin.  For visualization of stained cells by immunofluorescence or flow cytometry, the cells can be fixed in 2% paraformaldehyde for 15 minutes. The use of other organic solvents will extract the dye from the cells.  If internal labeling is desired, the cells can be permeabilized with saponin (50-75 μg/mL). Here is the link to the Troubleshooting Guide.

      ¿Le ha resultado útil?

1–10 de 11 Preguntas  

Revisiones

Sin puntuación

Filtros activos