Saltar al contenido
Merck
Todas las fotos(1)

Documentos clave

F6182

Sigma-Aldrich

Fluoroshield

liquid

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

20 ML
88,10 €

88,10 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
20 ML
88,10 €

About This Item

Código UNSPSC:
12171500
NACRES:
NA.47

88,10 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Nombre del producto

Fluoroshield, histology mounting medium

Nivel de calidad

Formulario

liquid

técnicas

immunofluorescence: suitable

intervalo de pH

7.8-8.2

solubilidad

water: soluble

aplicaciones

diagnostic assay manufacturing
hematology
histology

temp. de almacenamiento

2-8°C

Descripción general

Fluoroshield is an aqueous mounting medium for preserving fluorescence of tissue and cell smears. This unique formula not only enables prolonged fluorescence, but also prevents rapid photobleaching (fading) of fluorochromes including FITC, Texas Red®, AMCA, Cy®, Cy3, Cy5, Alexa Fluor 488, Alexa Fluor 594, Green fluorescent protein (GFP), tetramethylrhodamine, R-phycoerythrin (R-PE), phycocyanin (PC), and allophycocyanin (APC).

Aplicación

Fluoroshield has been used:
  • as a mounting medium for cultured megakaryocytes and immunostained platelets for confocal microscopy studies[1]
  • as a mounting medium for 4′,6-diamidino-2-phenylindole (DAPI) stained heart sections for immunofluorescence studies[2]
  • to preserve fluorescence of C6 cell smears[3]

Ligadura / enlace

Fluoroshield is an aqueous-based mounting medium comparable to Gel Mount.

Información legal

ALEXA FLUOR is a trademark of Life Technologies
Cy is a registered trademark of Cytiva
Cy3 is a trademark of Cytiva
FluoroShield is a trademark of ImmunoBioScience Corp.
Gel Mount is a trademark of Biomeda Corp.
Texas Red is a registered trademark of Life Technologies

Producto relacionado

Referencia del producto
Descripción
Precios

Código de clase de almacenamiento

10 - Combustible liquids

Clase de riesgo para el agua (WGK)

WGK 1

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Effects of dexamethasone on C6 cell proliferation, migration and invasion through the upregulation of AQP1
Guan Y, et al.
Oncology Letters, 15(5), 7595-7602 (2018)
Ahmed Baker Alshaikh et al.
Reproductive biology and endocrinology : RB&E, 18(1), 75-75 (2020-07-25)
Fertility preservation is particularly challenging in young women diagnosed with hematopoietic cancers, as transplantation of cryopreserved ovarian cortex in these women carries the risk for re-introducing cancer cells. Therefore, the construction of a bioengineered ovary that can accommodate isolated small
Douglas H Campbell et al.
PloS one, 13(4), e0196017-e0196017 (2018-04-20)
While measurement of serum prostate specific antigen (PSA) is an important screening tool for prostate cancer, new biomarkers are necessary for better discrimination between presence and absence of disease. The MIL-38 monoclonal antibody is specific for the membrane glycoprotein glypican
F Lodola et al.
Science advances, 5(9), eaav4620-eaav4620 (2019-10-11)
The control of stem and progenitor cell fate is emerging as a compelling urgency for regenerative medicine. Here, we propose a innovative strategy to gain optical control of endothelial colony-forming cell fate, which represents the only known truly endothelial precursor
Chenchen Yang et al.
Scientific reports, 8(1), 16359-16359 (2018-11-07)
Visibly transparent luminescent solar concentrators (TLSC) have the potential to turn existing infrastructures into net-zero-energy buildings. However, the reabsorption loss currently limits the device performance and scalability. This loss is typically defined by the Stokes shift between the absorption and

Artículos

Human Protein Atlas uses A-431, U-251 MG, and U-205 cell lines with Prestige Antibodies for organelle mapping.

Preguntas

1–9 de 9 Preguntas  
  1. What is the refractive index of this product (Fluoroshield Histology Mounting Medium, F6182)?

    1 respuesta
    1. The refractive index is 1.364 ± 0.002. This number applies to this mounting medium in solution. Refractive indexes change when the mounting media dries on the slide.

      ¿Le ha resultado útil?

  2. Does this product harden as it dries? Also, what is it's shelf life?

    1 respuesta
    1. This is an aqueous mounting medium and will dry over time if exposed to air, however this is unrelated to the intended use of the product. The mounting medium is applied over the sample prior to the addition of the coverslip. See the brief protocol below:

      1. Bring the vial to room temperature.
      2. Rinse slide to be mounted with DISTILLED OR DEIONIZED WATER, then touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface away from light.
      3. Turn the vial upside down and remove any air bubbles.
      4. Apply 3-4 drops directly of mounting medium on top of the specimen and spread out evenly by tilting the slide back and forth or spread evenly with a 0.2 ml plastic pipette tip, making sure the tissue is not touched. Excess medium can be removed by touching the edges of slide on paper towel.
      5. Let stand at room temperature for about 5 minutes.
      6. Apply cover slip, carefully avoiding air bubbles.
      7. The specimen is ready for visualization under microscope.
      8. One can seal the edges of cover slip with nail polish or any organic medium. If coverslip is not used air bubbles will appear in few days.
      9. For long term storage it is recommended that the slide be stored in the dark at 2-8°C.

      This product is assigned an expiration date of approximately one year. Please view the sample Certificate of Analysis: https://www.sigmaaldrich.com/certificates/sapfs/PROD/sap/certificate_pdfs/COFA/Q14/F6182-20ML-PWMKCT0475.pdf.

      ¿Le ha resultado útil?

  3. How do I store Fluoroshield (Product Nos. F6182, F5932, F6057) ?

    1 respuesta
    1. This product is stored at 2-8°C.  Protect from light, and do not freeze.

      ¿Le ha resultado útil?

  4. How do you remove the coverslip when using Fluoroshield (Product Nos. F6182, F5932, F6057)?

    1 respuesta
    1. The coverslip can be removed before sealing the edges. Soak slide in warm (37  °C) water for a few minutes. Carefully and slowly move the coverslip. Soak in water for an additional few minutes to remove coverslip. Rinse slide several times with warm water to remove all mounting medium. The slide can be remounted again.

      ¿Le ha resultado útil?

  5. How does the storage temperature relate to shipping conditions?

    1 respuesta
    1. The storage conditions that a Sigma-Aldrich catalog and label recommend for products are deliberately conservative. For many products, long-term storage at low temperatures will increase the time during which they are expected to remain in specification and therefore are labeled accordingly. Where short-term storage, shipping time frame, or exposure to conditions other than those recommended for long-term storage will not affect product quality, Sigma-Aldrich will ship at ambient temperature. The products sensitive to short-term exposure to conditions other than their recommended long-term storage are shipped on wet or dry ice. Ambient temperature shipping helps to control shipping costs for our customers. At any time, our customers can request wet- or dry-ice shipment, but the special handling is at customer expense if our product history indicates that the product is stable for regular shipment.

      ¿Le ha resultado útil?

  6. What is the Department of Transportation shipping information for this product?

    1 respuesta
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      ¿Le ha resultado útil?

  7. What fluorochromes can be used with Fluoroshield (Product Nos. F6182, F5932, F6057)?

    1 respuesta
    1. This unique formula prevents rapid photobleaching of FITC, Texas Red®, AMCA, Cy®2, Cy®3, Cy®5, Alexa Fluor® 488, Alexa Fluor® 594, green fluorescent protein (GFP), tetramethylrhodamine, R-phycoerythrin (R-PE), phycocyanin (PC), and allophycocyanin (APC).  Fluorescence is retained during prolonged storage at 4°C in the dark. This medium does not contain phenylenediamine, which destroys immunofluorescence of the Cy dyes, RP-E, PC and APC.

      ¿Le ha resultado útil?

  8. Does Fluoroshield (Product Nos. F6182, F5932, F6057) contain an antifade reagent?

    1 respuesta
    1. This unique formula prevents rapid photobleaching.  The exact nature of the antifade is considered proprietary.

      ¿Le ha resultado útil?

  9. How do I use Fluoroshield (Product Nos. F6182, F5932, F6057)?

    1 respuesta
    1. 1. Bring the vial to room temperature. 2. Rinse slide to be mounted with DISTILLED OR DEIONIZED WATER, then touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface away from light. 3. Turn the vial upside down and remove any air bubbles. 4. Apply 3-4 drops directly of mounting medium on top of the specimen and spread out evenly by tilting the slide back and forth or spread evenly with a 0.2 ml plastic pipette tip, making sure the tissue is not touched. Excess medium can be removed by touching the edges of slide on paper towel. 5. Let stand at room temperature for about 5 minutes. 6. Apply cover slip, carefully avoiding air bubbles. 7. The specimen is ready for visualization under microscope. 8. One can seal the edges of cover slip with nail polish or any organic medium. If coverslip is not used air bubbles will appear in few days. 9. For long term storage it is recommended that the slide be stored in the dark at 2-8°C.

      ¿Le ha resultado útil?

Revisiones

Sin puntuación

Filtros activos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico