If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
650463
Diclorometano
HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sinónimos:
Cloruro de metileno
About This Item
Productos recomendados
grado
HPLC Plus
for residue analysis
Nivel de calidad
densidad de vapor
2.9 (vs air)
presión de vapor
24.45 psi ( 55 °C)
6.83 psi ( 20 °C)
Ensayo
≥99.9%
Formulario
liquid
temp. de autoignición
1223 °F
contiene
50-150 ppm amylene as stabilizer
lim. expl.
22 %
técnicas
HPLC: suitable
gas chromatography (GC): suitable
impurezas
≤ 1.0 ppb Fluorescence (quinine) at 365 nm
≤0.01% water
residuo de evap.
≤0.0001%
residuo halogenado
≤10 ng/L (as heptachlor epoxide)
índice de refracción
n20/D 1.424 (lit.)
bp
39.8-40 °C (lit.)
mp
−95 °C (lit.)
densidad
1.325 g/mL at 25 °C (lit.)
λ
H2O reference
Absorción UV
λ: 235 nm Amax: 1.0
λ: 240 nm Amax: 0.10
λ: 250 nm Amax: 0.02
λ: 300-400 nm Amax: 0.005
idoneidad
suitable for residue analysis
cadena SMILES
ClCCl
InChI
1S/CH2Cl2/c2-1-3/h1H2
Clave InChI
YMWUJEATGCHHMB-UHFFFAOYSA-N
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
Descripción general
Aplicación
- Extracción de neonicotinoides de muestras de miel junto con acetonitrilo utilizando microextracción líquido-líquido dispersiva (DLLME)
- Extracción ultrasónica con disolventes y limpieza de muestras de café tostado para el análisis de 7 residuos de plaguicidas mediante cromatografía de líquidos-espectrometría de masas en tándem (LC-MS/MS)
- Preconcentración añadida mediante DLLME de los extractos de la muestra en el análisis de tres anfenicoles en productos alimenticios de origen animal mediante HPLC con detección
- Eliminación de la fase orgánica de los extractos obtenidos de la muestra de suelo en la determinación de dos herbicidas sulfonilurea utilizando HPLC
- Análisis de cuatro disolventes de extracción en el desarrollo de un método basado en la detección amperométrica mediante HPLC para el análisis de tres restos de carbamato en muestras de alimentos líquidos y sólidos
- Extracción de metrafenona de muestras vegetales por dispersión de matriz en fase sólida (método MSPD seguido de análisis HPLC
Envase
As a global leader in lab reagents, we are constantly looking for new ways to optimize the safety of our products. The newly developed 4L solvent bottle design features advanced sealing technology that eliminates leaks to make the handling of solvents safer and more convenient than ever before.
See all the new features here!
Otras notas
Información legal
Palabra de señalización
Warning
Frases de peligro
Consejos de prudencia
Clasificaciones de peligro
Carc. 2 - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
Órganos de actuación
Central nervous system
Código de clase de almacenamiento
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
Clase de riesgo para el agua (WGK)
WGK 2
Punto de inflamabilidad (°F)
does not flash
Punto de inflamabilidad (°C)
does not flash
Listados normativos
Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.
EU REACH Annex XVII (Restriction List)
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Artículos
Highly accurate HPLC-FLD method for evaluating 15 PAHs in olive oil using Ascentis® Express PAH HPLC column and SPE cleanup, following GB 5009.265-2021.
Protocolos
In the present study we demonstrate compliance of silica gel 60 F254 HPTLC plates with USP requirements, and how HPTLC plates are suitable for the Sildenafil citrate-Limit of Imidazole test.
-
How can I determine the shelf life / expiration / retest date of this product?
1 respuesta-
¿Le ha resultado útil?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 respuesta-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
¿Le ha resultado útil?
-
Filtros activos
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico