Pharmaceutical secondary standards for application in quality control provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards. Residual Solvents Mixture - Class IIA are certified reference materials (CRMs) for the analysis of residual solvents. The residual solvents can be found as mixtures, as single-analyte standards, as well as neat CRMs. These CRMs are secondary pharmaceutical reference standards and are traceable and qualified against the corresponding Pharmacopeial standards.
Aplicación
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.
Nota de análisis
These secondary standards offer multi-traceability to the USP, EP (PhEur) and BP primary standards, where they are available.
Otras notas
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.
Nota al pie de página
To see an example of a Certificate of Analysis for this material enter LRAB7797 in the slot below. This is an example certificate only and may not be the lot that you receive.
Analito
Descripción
Acetonitrile 2 mg/mL
Chlorobenzene 2 mg/mL
Cumene 0.3 mg/mL
Cyclohexane 14 mg/mL
cis-1,2-Dichloroethene 4 mg/mL
trans-1,2-Dichloroethene 4 mg/mL
Methylene Chloride 3 mg/mL
1,4-Dioxane 2 mg/mL
Methanol 15 mg/mL
Methylcyclohexane 5 mg/mL
Tetrahydrofuran 4 mg/mL
Toluene 4 mg/mL
Ethylbenzene 2 mg/mL
p-Xylene 1 mg/mL
m-Xylene 1 mg/mL
o-Xylene 7 mg/mL
Ver todo (16)
Punto de inflamabilidad (°F)
188.6 °F - closed cup
Punto de inflamabilidad (°C)
87 °C - closed cup
Listados normativos
Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.
The receptor-interacting serine/threonine-protein kinases RIPK1 and RIPK3 play important roles in necroptosis that are closely linked to the inflammatory response. Although the activation of necroptosis is well characterized, the mechanism that tunes down necroptosis is largely unknown. Here we find
Preguntas
Revisiones
★★★★★ Sin puntuación
Filtros activos
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.