Saltar al contenido
Merck

05892970001

Roche

cOmplete ULTRA Tablets, Mini, EASYpack Protease Inhibitor Cocktail

Tablets supplied in foil blister packs.

Sinónimos:

protease inhibitor

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
12352204
NACRES:
NA.28

formulario

tablet

envase

pkg of 30 tablets (individually packed in foil blister packs)

fabricante / nombre comercial

Roche

solubilidad

water: soluble

absorción

0.4 at 280 nm (1x solution)

temp. de almacenamiento

2-8°C

Descripción general

cOmplete ULTRA Tablets contain the most powerful protease inhibitor cocktail for the optimal protection of your proteins against protease degradation. As this tablet contains EDTA, metalloproteases are also inhibited. They are supplied as tablets in an EASYpack blister pack. EASYpacks provide the most convenient form of delivery - single tablets are easily pushed through the blister foil directly into the buffer. One cOmplete ULTRA, Mini Tablet is sufficient for a volume of 10 ml extraction solution.
Recombinant proteins may be partially degraded during expression. Soluble degradation products are co-purified and cause a non-homogeneous protein preparation with protein fragments of different lengths. Metalloproteases, which are inhibited by EDTA, are fairly prevalent in, for example, bacteria.

You can easily inhibit both proteases and phosphatases at the same time by simply combining a cOmplete ULTRA, Mini, Protease Inhibitor Cocktail Tablet with a PhosSTOP Phosphatase Inhibitor Cocktail Tablet in the same 10 ml buffer.

Especificidad

Inhibits serine proteases, cysteine proteases. Does not inhibit metalloproteases completely when divalent cations like Ca2+, Mg2+, or Mn2+ are present

Aplicación

During cell lysis and purification, target proteins are at risk of being cleaved by proteases, which are naturally present in cells. To ensure that full-length proteins are obtained, cOmplete ULTRA Tablets are used for the inhibition of an extended range of proteases. This new formulation shows highest inhibition ratios due to its broadened range of inhibitors compared to standard cOmplete Tablets.
This new protease inhibitor cocktail now inhibits aspartic proteases, as well as serine, cysteine, and metalloproteases. cOmplete ULTRA Tablets were developed for maximum efficiency on different cell types. Best performance is guaranteed in lysates of bacteria, yeast, insect cells, and a wide range of higher cell lines.
Roche ′s new resin for the purification of his-tagged proteins, cOmplete His-Tag Purification Resin, is compatible with this EDTA-containing tablet. Due to a new metal ion-binding-chelator chemistry in the cOmplete His-Tag Purification Resin, EDTA can be used during Immobilized Metal Ion Affinity Chromatography (IMAC).
cOmplete ULTRA Tablets, Mini, EASYpack Protease Inhibitor Cocktail has been used as a component of radioimmunoprecipitation assay buffer (RIPA buffer). It has also been used to prevent protein degradation and coagulation in blood samples.

Características y beneficios

  • Ultra efficient protection
The extended inhibitor cocktail composition makes this tablet an ideal formulation for your most difficult, protease-sensitive targets.
  • Convenient tablet format
Eliminate weighing small amounts, and instantly protect your proteins against an exceptionally wide range of proteases by simply pushing a tablet through the EASYpack foil packaging directly into your buffers.
  • Suitable for IMAC purification
Purify poly-histidine tagged proteins.
  • Ensure laboratory safety
Avoid contact with hazardous compounds using cOmplete ULTRA Tablets.

Componentes

Proprietary mixture of several protease inhibitors with broad inhibitory specificity.

Forma física

Tablets in foil blister packs. Each tablet is sufficient for a volume of 10 ml extraction solution.

Nota de preparación

Working concentration: 1 tablet per 10 ml extraction solution.
Working solution: Handling

Carefully push the tablet through the foil packaging using the base of your thumb (not your fingernail) to prevent the breakage of tablets.

Preparation of Working Solution

One tablet is sufficient for the inhibition of proteolytic activity in 10 ml extraction solution. If very high proteolytic activity is present, 2-3 tablets should be used for 10 ml extraction buffer. The tablets can be added directly to the extraction medium.

Stock Solution (2x conc.)

Alternatively to the direct use with lysates, a 2x stock solution can be prepared, with the following procedure:
• Add cOmplete ULTRA Tablet to 5 ml double-distilled water in a PE or PP tube.
• Vortex 3 min or until the tablet is completely dissolved.
• The stock solution is ready to use even if there are very fine parti­cles still visible in solution. These particles do not interfere with the inhibition performance of the tablets.
• Stock solution is stable for 4 weeks, stored at 2 to 8 °C, and for at least 4 weeks at  -15 to  -25 °C as well.
• During storage of the 2x stock solution, the particles can sediment. Briefly vortex the stock solution prior to use.

Storage conditions (working solution): The stock solution in water is stable for 4 weeks, stored at 2 to 8 °C, and for at least 4 weeks at  -15 to -25 °C as well.

Reconstitución

Soluble in aqueous buffers, or add directly to extraction media.

For the stock solution, use water only.

Otras notas

For life science research only. Not for use in diagnostic procedures.

Información legal

cOmplete is a trademark of Roche

Pictogramas

Corrosion

Palabra de señalización

Danger

Frases de peligro

Clasificaciones de peligro

Aquatic Chronic 3 - Eye Dam. 1 - Skin Corr. 1B

Código de clase de almacenamiento

8A - Combustible, corrosive hazardous materials

Clase de riesgo para el agua (WGK)

WGK 2

Punto de inflamabilidad (°F)

does not flash

Punto de inflamabilidad (°C)

does not flash


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Yukiko Yasuoka et al.
Physiological reports, 8(12), e14485-e14485 (2020-06-28)
The detection of erythropoietin (Epo) protein by Western blotting has required pre-purification of the sample. We developed a new Western blot method to detect plasma and urinary Epo using deglycosylation. Epo in urine and tissue, and erythropoiesis-stimulating agents (ESAs) in
Pharmacokinetic parameters and mechanism of action of an efficient anti-A$\beta$ single chain antibody fragment
Esquerda-Canals G, et al.
Testing, 14(5), e0217793-e0217793 (2019)
Jesse J Balic et al.
Nature communications, 11(1), 3816-3816 (2020-08-01)
Detection of microbial components such as lipopolysaccharide (LPS) by Toll-like receptor 4 (TLR4) on macrophages induces a robust pro-inflammatory response that is dependent on metabolic reprogramming. These innate metabolic changes have been compared to aerobic glycolysis in tumour cells. However
3-Hydroxyisoindolin-1-one derivates: Synthesis by palladium-catalyzed CH activation as BRD4 inhibitors against human acute myeloid leukemia (AML) cells
Chen P, et al.
Bioorganic Chemistry, 86, 119-125 (2019)
Yinan Li et al.
eLife, 9 (2020-10-02)
Terminal selectors are transcription factors (TFs) that establish during development and maintain throughout life post-mitotic neuronal identity. We previously showed that UNC-3/Ebf, the terminal selector of C. elegans cholinergic motor neurons (MNs), acts indirectly to prevent alternative neuronal identities (Feng

Contenido relacionado

Select different protease inhibitor types based on your needs to prevent protein degradation during isolation and characterization and safeguard proteins in sample prep.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico