The SCT152 kit is sufficient for approximately 150 reactions. Here is the data sheet: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/815/113/sct152ds.pdf
Seleccione un Tamaño
| Talla/SKU | Disponibilidad | Precio |
|---|---|---|
1 kit | Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad | 328,00 € |
Acerca de este artículo
328,00 €
technique(s)
cell based assay: suitable
detection method
chemiluminescent
shipped in
ambient
storage temp.
-65 to -96°C
General description
El ensayo de luciferasa doble de luciérnaga/Renilla permite medir la actividad luciferasa de luciérnaga y Renilla en la misma muestra con gran sensibilidad y linealidad. Primero se mide la actividad luciferasa de la luciérnaga, luego se agrega el tampón de ensayo de luciferasa de Renilla 2.0 para extinguir la actividad luciferasa de luciérnaga y medir simultáneamente la actividad luciferasa. de Renilla El tampón para el ensayo luciferasa Renilla 2.0 extingue la actividad luciferasa de la luciérnaga al nivel de las células no transfectadas, permitiendo la medición secuencial de la actividad luciferasa de luciérnaga y Renilla en la misma muestra. Se trata de un ensayo de tipo flash que requiere medir la luminiscencia inmediatamente después de agregar los reactivos de detección a la muestra de luciferasa. La señal de la luciérnaga va decayendo en el transcurso de unos 12 minutos, mientras que la señal de Renilla desaparece en el transcurso de unos 2 minutos, aunque esto puede variar dependiendo de las concentraciones de enzima.
Application
Comunicación celular
Tinción de células vivas
Physical form
Preparation Note
Other Notes
2) Tampón de ensayo de luciferasa de luciérnaga 2.0 (CS224591): 15 ml
3) D-luciferina (CS224551): 3 X 1 mg
4) Tampón de ensayo de luciferasa de renilla 2.0 (CS224580): 15 ml
5) Coelentarazina Aquaphile (CS224581): 3 X 200 µg
Disclaimer
1 of 1
Este artículo | |||
|---|---|---|---|
| description Flash-type dual luciferase assay that allows measurement of both Firefly and Renilla luciferase activity in the same sample with high sensitivity and linearity. | description Flash-type luciferase assay designed for simple and efficient quantitation of firefly luciferase reporter enzyme activity from cultured cells with high sensitivity and linearity. | description Lyophilized flash-type luciferase assay designed for simple and efficient quantitation of firefly luciferase reporter enzyme activity from cultured cells with high sensitivity and linearity. | description Glow-type luciferase assay for the quantification of firefly luciferase gene expression in mammalian cells with signal half-life of about 3 hours |
| technique(s) cell based assay: suitable | technique(s) cell based assay: suitable | technique(s) cell based assay: suitable | technique(s) cell based assay: suitable |
| shipped in ambient | shipped in ambient | shipped in ambient | shipped in ambient |
| storage temp. -65 to -96°C | storage temp. -65 to -96°C | storage temp. -10 to -25°C | storage temp. -65 to -96°C |
| detection method chemiluminescent | detection method chemiluminescent | detection method chemiluminescent | detection method chemiluminescent |
Clase de almacenamiento
10 - Combustible liquids
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
What volume of reagent, how many assays from one kit, what plates are needed and how is assay run? - very little information currently on webpage.
1 respuesta-
¿Le ha resultado útil?
-
-
How many reactions is it designed for?
1 respuesta-
This kit includes a several components, including 3 x 200 ug Aquaphile Coelenterazine. Each 200 ug vial is sufficient to perform 50 tests when used as directed. Please see the link below to review the kit protocol:
https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/815/113/sct152ds.pdf¿Le ha resultado útil?
-



