The recommended alternative product is S2GPU05RE, Stericup Quick Release-GP Sterile Vacuum Filtration System from Millipore. This system includes a 500 mL Steritop bottle top filter unit utilizing a 0.22 µm pore size fast flow PES Express PLUS membrane, along with a 500 mL receiver flask for the sterilization of tissue culture media, protein, and DNA.
S2GPU05RE
Sistema de filtración al vacío Millipore® Stericup® Quick Release
pore size 0.22 μm, polyethersulfone membrane, funnel capacity 500 mL, pack of 12 ea
Sinónimos:
SCGPU05RE, Sistema de filtración al vacío estéril Stericup Quick Release-GP
Seleccione un Tamaño
About This Item
Productos recomendados
Materiales
polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing
Nivel de calidad
esterilidad
sterile; irradiated
Línea del producto
Stericup®
Características
hydrophilic
envase
pack of 12 ea
Parámetros
45 °C max. temp.
descripción
2.4 mL (hold-up volume)
técnicas
sterile filtration: suitable
Altura
263 mm
capacidad
500 mL
Diámetro
12.5 cm
diám. del filtro
73 mm
filtración área
40 cm2
embudo capacidad
500 mL
Matriz
Express PLUS™
tamaño de poro
0.22 μm pore size
Adaptador
inlet funnel
outlet flask (Receiver)
Condiciones de envío
ambient
Descripción general
Aplicación
- Medios de cultivo de tejidos +/- aditivos
- Amortiguadores
- Disoluciones biológicas
Características y beneficios
- El embudo de filtración Quick Release se desconecta de la botella receptora con solo un cuarto de vuelta—reduciendo así la probabilidad de derrame y haciendo que sea más fácil Manipularlo en la mesa de trabajo y debajo de la campana.
- La identificación del producto en negrita en el embudo de filtración Steritop® muestra claramente las características de la membrana, como su composición y el tamaño de los poros, una selección de productos rápida y apropiada para la aplicación.
- El tapón de cierre mediante un clic está bridado y modificado para permitir un fuerte agarre en condiciones secas—y un tope táctil confirma el cierre seguro. Preocúpese menos de la posibilidad de derramar o contaminar el contenido esterilizado.
- La amplia superficie esmerilada de escritura en la botella receptora y el color más claro del tapón facilitan el etiquetado claro para mejorar la legibilidad y reducir los frotis ilegibles.
- La tapa descansa sobre el lateral para evitar el riesgo de contaminación.
- Las botellas receptoras son apilables para ahorrar espacio de almacenamiento.
Información legal
¿No encuentra el producto adecuado?
Pruebe nuestro Herramienta de selección de productos.
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Artículos
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.
Ensure optimal cell culture outcomes with ultrapure, endotoxin-free water. Learn about the impact of water impurities on mammalian cell cultures and how to achieve optimal cell growth.
Overview on how to maintain proper cell culture laboratory safety including steps on performing lab risk assessments, surface disinfection, biohazard and waste removal. Free ECACC handbook download.
Contenido relacionado
What are you filtering out? What do you want to keep? Pick the right membrane for your filtration.
Learn how to effectively filter fetal bovine serum (FBS) using Stericup® Quick Release vacuum filtration devices, including flow test data and analysis.
This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.
-
What is the Corning alternative for the product CLS431097, which is a Corning® bottle-top vacuum filter system with specific features like a polyethersulfone membrane, pore size of 0.22 μm, membrane area of 33.2 cm2, and a filter capacity of 500 mL?
1 respuesta-
¿Le ha resultado útil?
-
-
Can Stericup® and Steritop® filters be reused?
1 respuesta-
All Stericup® and Steritop® filters were developed for single use, disposable processing.
¿Le ha resultado útil?
-
-
What tubing can be used with Stericup® and Steritop® vacuum filters?
What tubing can be used with Stericup® and Steritop® vacuum filters?
1 respuesta-
Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004
¿Le ha resultado útil?
-
-
What is the expiration date of Stericup® and Steritop® filters?
1 respuesta-
Typically 3 years from sterilization.
¿Le ha resultado útil?
-
-
Can Stericup® bottles be placed inside freezers for long-term storage of media?
1 respuesta-
You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.
¿Le ha resultado útil?
-
-
What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?
1 respuesta-
All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
*Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.¿Le ha resultado útil?
-
-
What is the chemical compatibility of the various Stericup® and Steritop® filters?
What is the chemical compatibility of the various Stericup® and Steritop® filters?
1 respuesta-
Please refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
¿Le ha resultado útil?
-
-
What Bacterial Endotoxins Test is used?
1 respuesta-
The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.
¿Le ha resultado útil?
-
-
Can we filter oil-type liquids with Stericup® filters?
Can we filter oil-type liquids with Stericup® filters?
1 respuesta-
Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
¿Le ha resultado útil?
-
-
The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?
1 respuesta-
Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
Glass bottles, GL33:
• Wheaton media bottles (glass), 500 mL (Product Z364886)
• Wheaton media bottles (glass), 1 L (Product Z364894)
Glass bottles, GL45
• Corning® glass media storage bottle, 125 mL (Product CLS1399125)
• Corning® glass media storage bottle, 250 mL (Product CLS1399250)
• Corning® glass media storage bottle, 500 mL (Product CLS1399500)
• Corning® glass media storage bottle, 1 L (Product CLS13991L)
• Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
• Pyrex® round media storage bottle, 1 L (Product CLS13951L)
• KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
• KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
• KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
Plastic (pre-sterile) bottles, GL45:
• Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
• Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
• Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)¿Le ha resultado útil?
-
Filtros activos
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico