Seleccione un Tamaño
| Talla/SKU | Disponibilidad | Precio |
|---|
Acerca de este artículo
Nombre del producto
Casete Pellicon® XL con membrana Durapore®, Chemistry: Polyvinylidene Fluoride (PVDF) Screen Type: C Device Size: 50 cm²
Quality Segment
material
PVDF membrane, polypropylene , polypropylene screen
product line
Pellicon®
feature
holdup volume 3.2 mL
manufacturer/tradename
Pellicon®
parameter
0.03-0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C
technique(s)
analytical sample preparation: suitable, protein purification: suitable, tangential flow filtration (TFF): suitable
L
18.8 cm (7.4 in.)
W
3 cm (1.2 in.)
filtration area
50 cm2
membrane nominal area
50 cm2
gravimetric extractables
≤7.5 mg/device
matrix
Durapore®
pore size
0.65 μm nominal pore size, 0.65 μm pore size
pH
1-11(cleaning), 1.5-9(continuous)
shipped in
ambient
General description
Features and Benefits
Analysis Note
Other Notes
Legal Information
1 of 1
Este artículo | |||
|---|---|---|---|
| description Chemistry: Polyvinylidene Fluoride (PVDF) Screen Type: C Device Size: 50 cm² | description Chemistry: Polyvinylidene Fluoride (PVDF) Screen Type: C Device Size: 50 cm² | description Chemistry: Polyvinylidene Fluoride (PVDF) Screen Type: C Device Size: 50 cm² | description Chemistry: Polyvinylidene Fluoride (PVDF) Screen Type: C Device Size: 50 cm² |
| pore size 0.65 μm nominal pore size, 0.65 μm pore size | pore size 0.45 μm pore size, 0.45 μm nominal pore size | pore size 0.1 μm pore size, 0.1 μm nominal pore size | pore size 0.22 μm nominal pore size, 0.22 μm pore size |
| filtration area 50 cm2 | filtration area 50 cm2 | filtration area 50 cm2 | filtration area 50 cm2 |
| technique(s) protein purification: suitable, analytical sample preparation: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable |
| matrix Durapore® | matrix Durapore® | matrix Durapore® | matrix Durapore® |
| material polypropylene , polypropylene screen, PVDF membrane | material PVDF membrane, polypropylene , polypropylene screen | material PVDF membrane, polypropylene screen | material polypropylene screen, PVDF membrane |
| parameter 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C, 0.03-0.05 L/min recirculation rate, 15 mL min. working volume | parameter 15 mL min. working volume, 5.5 bar max. inlet pressure (80 psi) at 50 °C, 0.03–0.05 L/min recirculation rate, 2.8 bar max. transmembrane pressure (40 psig) | parameter 5.5 bar max. inlet pressure (80 psi) at 50 °C, 15 mL min. working volume, 0.03–0.05 L/min recirculation rate, 2.8 bar max. transmembrane pressure (40 psig) | parameter 2.8 bar max. transmembrane pressure (40 psig), 15 mL min. working volume, 0.03–0.05 L/min recirculation rate, 5.5 bar max. inlet pressure (80 psi) at 50 °C |
Still not finding the right product?
Explore all of our products under Casete Pellicon® XL con membrana Durapore®
Clase de almacenamiento
12 - Non Combustible Liquids
Punto de inflamación (°F)
Not applicable
Punto de inflamación (°C)
Not applicable
¿Qué está pasando?
WGK 2
Listados normativos
Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.
64-19-7
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.