Saltar al contenido
Merck
Todas las fotos(1)

Documentos

CBA024

Sigma-Aldrich

InnoZyme Myeloperoxidase Activity Kit

Sinónimos:

InnoZyme MPO Activity Kit

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
41116133
NACRES:
NA.77

uso

sufficient for 96 tests

Nivel de calidad

reactividad de especies

human

envase

pkg of 1 96-well plate(s)

fabricante / nombre comercial

Calbiochem®

condiciones de almacenamiento

OK to freeze
avoid repeated freeze/thaw cycles
protect from light

assay range

sensitivity: 330 pg/mL
standard curve range: 5-100 ng/mL

entrada

sample type serum
sample type cerebrospinal fluid (CSF)
sample type cell lysate

método de detección

colorimetric

Condiciones de envío

wet ice

temp. de almacenamiento

−20°C

Descripción general

The InnoZyme Myeloperoxidase Activity Kit is a specific and sensitive assay designed to measure myeloperoxidase activity and to screen enzyme inhibitors. The assay uses a polyclonal antibody specific for human MPO immobilized on a 96-well plate to specifically capture the enzyme. Activity of captured myeloperoxidase is measured using a detection reagent that includes TMB and hydrogen peroxide. Following color development, the reaction is stopped with sulfuric acid and the absorbance of the oxidized TMB is detected at 450 nm.

Componentes

Anti-MPO Coated 96-Well Plate, MPO Standard, TMB, Hydrogen Peroxide, Assay Buffer, Sample Buffer, Stop Solution, Plate Sealers, and a user protocol.

Advertencia

Toxicity: Multiple Toxicity Values, refer to MSDS (O)

Especificaciones

Assay Time: 2 h

Principio

The Calbiochem InnoZyme Myeloperoxidase Activity Kit is designed to measure human myeloperoxidase activity in cell lysates and biological samples and to screen enzyme inhibitors.

Nota de preparación

All reagents necessary to perform the assay are supplied with the kit. Equilibrate all reagents to room temperature (15-25°C) just prior to use.Sample Buffer (1X): Dilute Sample Buffer 1:20 by adding 25 ml Sample Buffer to 475 ml dH2O. Myeloperoxidase Standard (1g/ml): Dilute the Myeloperoxidase Standard 1:100 by adding 5 l Myeloperoxidase Standard to 495 l chilled Sample Buffer (1X) obtain a concentration of 1 g/ml. Maintain the diluted Myeloperoxidase Standard (1 g/ml) on ice. Note: Following initial thaw the Myeloperoxidase Standard should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles.<div class="Bio_doc_image">
Table 1: Myeloperoxidase Standard Dilutions
Prepare Myeloperoxidase Standard dilutions in the range of 5-100 ng/ml using the above guidelines.
</div>Hydrogen Peroxide (0.3%): Dilute the Hydrogen Peroxide (30%) 1:100 by adding 5 l Hydrogen Peroxide (30%) to 495 l chilled dH2O. Note: A total of 40 l is required to cover the entire Coated 96-Well Plate. If the entire plate is not to be used at one time, prepare fresh Hydrogen Peroxide (0.3%) each time the assay is performed. Following initial thaw the Hydrogen Peroxide should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles.TMB Detection Reagent: Note: The desired amount of TMB Detection Reagent should be prepared fresh, just prior to use. To prepare TMB Detection Reagent, mix the following components:
  • 7.16 ml dH2O
  • 2.00 ml Assay Buffer
  • 0.80 ml TMB
  • 40 l H2O2(0.3%)

Vortex gently 3 X 3 sTo prepare TMB Detection Reagent for a variable number of strips, use the following guidelines: <div class="Bio_doc_image">Table 2: Preparation of TMB Detection Reagent
To prepare TMB Detection Reagent for a variable number of strips, use the above guidelines.
</div>
Dilute samples with Sample Buffer (1X) as needed. Note: If sample dilution is not required for sensitivity reasons, prepare the sample by adding 475 µl sample to 25 µl 20X Sample Buffer to ensure appropriate pH for the first incubation.

Almacenamiento y estabilidad

Upon arrival, store the unopened kit at -20°C. All kit components, once opened, can be stored for up to 3 months under the following conditions:



Store at 4°C: TMB, Anti-MPO Coated 96-Well Plate, Assay Buffer, Stop Solution, and Sample Buffer

Store at -20°C: Myeloperoxidase Standard, and Hydrogen Peroxide



Note: Following initial use the Myeloperoxidase Standard and the Hydrogen Peroxide should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles.

Nota de análisis

Positive Control
Human myeloperoxidase

Otras notas

Due to the nature of the Hazardous Materials in this shipment, additional shipping charges may be applied to your order. Certain sizes may be exempt from the additional hazardous materials shipping charges. Please contact your local sales office for more information regarding these charges.
Weil, S.C., et al. 1988. Science 240, 790.
Winterbourn, C.C., et al. 2000. Curr. Opin. Hematol. 7, 53.
Brennan, M.L., et al. 2003. New Engl. J Med. 349, 1595.
Zheng, L., et al. 2004. J. Biol. Chem. in press
Vita, J.A., et al. 2004. Circulation, 110, 1134.

Información legal

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogramas

CorrosionExclamation mark

Palabra de señalización

Danger

Frases de peligro

Clasificaciones de peligro

Eye Dam. 1 - Met. Corr. 1 - Skin Irrit. 2 - Skin Sens. 1

Código de clase de almacenamiento

8A - Combustible corrosive hazardous materials


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Alessandro Trentini et al.
Inflammation research : official journal of the European Histamine Research Society ... [et al.], 63(5), 325-328 (2014-01-25)
We investigated the effect of balanced (BS) and unbalanced (UBS) solutions in the absence or presence of hydroxyethyl starch (HES) on neutrophil functionality, evaluating the release of matrix metalloproteinase (MMP)-9, myeloperoxidase (MPO), and MMP-8. Neutrophils were isolated by gradient centrifugation

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico