Saltar al contenido
Merck

GF60075930

Silver

foil, 6mm disks, thickness 0.125mm, as rolled, 99.95+%

Sinónimos:

Silver, AG000400

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

10 EA
870,00 €

870,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
10 EA
870,00 €

About This Item

Fórmula lineal:
Ag
Número de CAS:
Peso molecular:
107.87
Número MDL:
Código UNSPSC:
12141740
ID de la sustancia en PubChem:
NACRES:
NA.23

870,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Ensayo

99.95%

Formulario

foil

fabricante / nombre comercial

Goodfellow 600-759-30

resistividad

1.59 μΩ-cm, 20°C

diám. × grosor

6 mm × 0.125 mm

bp

2212 °C (lit.)

mp

960 °C (lit.)

densidad

10.49 g/cm3 (lit.)

cadena SMILES

[Ag]

InChI

1S/Ag

Clave InChI

BQCADISMDOOEFD-UHFFFAOYSA-N

Descripción general

For updated SDS information please visit www.goodfellow.com.

Información legal

Product of Goodfellow

Código de clase de almacenamiento

13 - Non Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Fan Yang et al.
Talanta, 84(4), 1099-1106 (2011-05-03)
In this paper, a compact and inexpensive light emitting diode induced fluorescence (LED-IF) detector with simplified optical configuration was developed and assembled in an integrated microfluidic device for microscale electrophoresis. The facile detector mainly consisted of an LED, a focusing
R D Stickrod et al.
Rapid communications in mass spectrometry : RCM, 14(14), 1266-1268 (2000-08-05)
Nitrate-delta(15)N from groundwater samples is determined on an inorganic nitrate derivative using automated, continuous-flow elemental analyzer/isotope ratio mass spectrometry (EA/IRMS). Nitrate is extracted and concentrated based on a recently published ion-exchange resin method. Freeze-dried AgNO(3) (0.5-1.5 mg) is packed in
M Dubiel et al.
Journal of synchrotron radiation, 8(Pt 2), 539-541 (2001-08-22)
The thermal expansion behaviour of silver fcc has been described by an anharmonic Einstein model using EXAFS data in the temperature range between 10 and 300 K. The linear expansion coefficient of a bulk silver foil agrees well with X-ray
A Rupérez et al.
Talanta, 44(2), 213-220 (1997-02-01)
Surface-enhanced Raman scattering (SERS) spectrometry of the diuretic drug triamterene is discussed. The SERS-active substrate used is a silver foil etched with nitric acid. The influence of solvent and sample doping method on sensivity, intercept and shape of the calibration
G J Hoffman et al.
Science (New York, N.Y.), 177(4051), 802-804 (1972-09-01)
The water potential of leaves in situ can be measured without temperature control with a miniature, single-junction psychrometer constructed from silver foil and attached to the leaf with a silver-impregnated, conductive coating. The temperature of the psychrometer has been found

Preguntas

Revisiones

Sin puntuación

Filtros activos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico