Saltar al contenido
Merck

719846

Sigma-Aldrich

Resomer® X 206 S, poly(dioxanone)

Sinónimos:

PDS

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

5 G
267,00 €

267,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
5 G
267,00 €

About This Item

Fórmula lineal:
(C4H6O3)n
Número de CAS:
Número MDL:
Código UNSPSC:
12162002
NACRES:
NA.23

267,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Formulario

solid

Nivel de calidad

marco temporal de la degradación

<6 months

viscosidad inherente

1.5-2.2 dL/g, 0.1 % (w/v) in hexafluoroisopropanol(30 °C, Ubbelohde) (size 0c glass capillary viscometer)

temperatura de transición

Tg −10-−5 °C
Tm 110-115 °C

temp. de almacenamiento

−20°C

cadena SMILES

O1CCOC(=O)C1

InChI

1S/C4H6O3/c5-4-3-6-1-2-7-4/h1-3H2

Clave InChI

VPVXHAANQNHFSF-UHFFFAOYSA-N

Descripción general

Polydioxanone (PDO) is a colorless, crystalline, highly flexible and resorbable biopolymer.[1]

Aplicación

PDO is widely used as a monofilament wound suture.[2] PDO/elastin-based blends prepared by electrospinning may be used as cardiovascular grafts.[1]

Información legal

Product of Evonik
RESOMER is a registered trademark of Evonik Rohm GmbH

Código de clase de almacenamiento

11 - Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Mitchell D Eggers et al.
Journal of vascular and interventional radiology : JVIR, 23(8), 1023-1030 (2012-07-31)
To test absorbable materials as a prelude to development of an absorbable vena cava filter for the prevention of pulmonary embolism (PE). Three absorbing polymer candidates, poliglecaprone (Monocryl; sizes 4-0 and 1), polyglactin (Vicryl; sizes 4-0 and 1), and polydioxanone
O Hakimi et al.
European cells & materials, 24, 344-357 (2012-10-24)
Rotator cuff tendon pathology is thought to account for 30-70 % of all shoulder pain. For cases that have failed conservative treatment, surgical re-attachment of the tendon to the bone with a non-absorbable suture is a common option. However, the failure
Jean W M Gardeniers et al.
Clinical orthopaedics and related research, 471(7), 2225-2230 (2013-03-06)
Surgical treatment options for sternoclavicular joint luxations described in the literature are numerous, although all have limitations. Therefore, there is no favorable surgical treatment for sternoclavicular luxations when nonoperative treatment has failed. We developed the polydioxanone (PDS) envelope plasty, a
Ruan Zheng et al.
European review for medical and pharmacological sciences, 16(7), 942-948 (2012-09-08)
With the development of surgical techniques and biomedical material, increasing synthetic materials are applied to the chest wall reconstruction, such as autologous rib, muscle flap, bovine pericardium and sheet metal. To detect the safety and efficiency of synthetic material Polydioxanone
Georgette Oni et al.
Plastic and reconstructive surgery, 130(4), 535e-540e (2012-09-29)
The use of knotless barbed sutures has shortened operation times for wound closure. In experimental models, their use in tendon surgery is still under investigation. This study looks at the use of barbed sutures in a porcine model for fascial

Artículos

Main features of p-dioxanone, glycolide and lactide based copolymers

Interest in utilizing biodegradable polymers for biomedical applications has grown since the 1960s.

AliAliphatic polyesters, including polylactide and polyglycolide, are biodegradable polymers widely used in medical applications.

Immunosuppressive tumor-associated myeloid cells (TAMC) are responsible for glioblastoma (GBM) resistance to immunotherapies and existing standard of care treatments. This mini-review highlights recent progress in implementing nanotechnology in advancing TAMC-targeted therapies for GBM.

Ver todo

Preguntas

  1. What's the molecular weight ?

    1 respuesta
    1. Unfortunately, there is no molecular weight provided by the supplier for this product. The information is proprietary.

      ¿Le ha resultado útil?

Revisiones

Sin puntuación

Filtros activos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico