If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
50139-U
LiChrospher® RP-18 endcapped (5 µm) HPLC Columns
L × I.D. 25 cm × 4.6 mm, HPLC Column
Synonyme(s) :
TM=["LiChrospher"] C18 HPLC column
About This Item
Produits recommandés
Nom du produit
Colonne HPLC LiChrospher® RP-18, 5 μm particle size, L × I.D. 25 cm × 4.6 mm, endcapped
Matériaux
stainless steel column
Niveau de qualité
Agence
suitable for USP L1
Gamme de produits
LiChrospher®
Caractéristiques
endcapped
Fabricant/nom de marque
LiChrospher®
Conditionnement
1 ea of
Ampleur du marquage
21% Carbon loading
Paramètres
≤65 °C temperature
≤70 °C temp. range
400 bar pressure (5801 psi)
Technique(s)
HPLC: suitable
L × D.I.
25 cm × 4.6 mm
Superficie
350 m2/g
Matrice
octadecyl
silica particle platform
fully porous particle
Groupe de la matrice active
C18 (octadecyl) phase
Taille des particules
5 μm
Dimension de pores
100 Å
pH de fonctionnement
2-7.5
Application(s)
food and beverages
Technique de séparation
reversed phase
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Catégories apparentées
Description générale
Application
- HPLC-UV and GC-MS Methods for Determination of Chlorambucil and Valproic Acid in Plasma for Further Exploring a New Combined Therapy of Chronic Lymphocytic Leukemia.: This study illustrates the efficiency of the LiChrospher® RP-18 HPLC Column in a novel approach to analyzing the pharmacokinetics of chlorambucil and valproic acid, providing critical data for potential combined therapy options in treating chronic lymphocytic leukemia (Lipska et al., 2021).
- Rapid Determination of Metronidazole and 2-Hydroxymetronidazole in Murine Blood Plasma.: Utilizes the LiChrospher® RP-18 HPLC Column to establish a rapid and accurate method for the analysis of metronidazole and its metabolites in blood plasma, enhancing the understanding of its pharmacological impacts and supporting more effective therapeutic strategies (Zemanova et al., 2022).
- Application of chemometric approach for development and validation of high performance liquid chromatography method for estimation of ropinirole hydrochloride.: Demonstrates the application of the LiChrospher® RP-18 HPLC Column in optimizing a chemometrically enhanced method for the determination of ropinirole hydrochloride, aimed at improving treatment strategies for Parkinsons disease (Fatima et al., 2019).
- Application of an HPLC-MS/MS method for Teicoplanin drug substance and related impurities, part 2: Identity assignment of related impurities.: This research highlights the capability of the LiChrospher® RP-18 HPLC Column in detailed impurity profiling of teicoplanin, critical for maintaining drug purity and efficacy in antibiotic treatments (Tengattini et al., 2019).
Informations légales
Code de la classe de stockage
11 - Combustible Solids
Classe de danger pour l'eau (WGK)
WGK 3
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.
Si vous avez besoin d'assistance, veuillez contacter Service Clients
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
hello, is the column generation solution 0.1 ml of formic acid in 100 2-propanol?
1 answer-
The column generation solution for this product is 0.1% formic acid in 99.9 mL of 2-propanol.
Please view the link below: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/213/919/regeneracao-de-coluna.pdfHelpful?
-
-
how to regenerate reversed phase column
1 answer-
Please visit below link for the recommended column regeneration procedures: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/213/919/regeneracao-de-coluna.pdf