Accéder au contenu
Merck
Toutes les photos(1)

Documents

ARK2190

SAFC

N,N-diméthylacétamide

Ph. Eur.

Fabrication pharma

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
CH3CON(CH3)2
Numéro CAS:
Poids moléculaire :
87.12
Numéro Beilstein :
1737614
Numéro CE :
Numéro MDL:
Code UNSPSC :
12352111
Nomenclature NACRES :
NA.21

Agence

Ph. Eur.

Niveau de qualité

Densité de vapeur

3 (vs air)

Pression de vapeur

2 mmHg ( 25 °C)
4 mmHg ( 38 °C)

Forme

liquid

Température d'inflammation spontanée

914 °F

Limite d'explosivité

1.8 %, 100 °F
11.5 %, 160 °F

Indice de réfraction

n20/D 1.437 (lit.)

Point d'ébullition

164.5-166 °C (lit.)

Pf

−20 °C (lit.)

Densité

0.937 g/mL at 25 °C (lit.)

Adéquation

suitable for manufacturing use

Température de stockage

room temp

Chaîne SMILES 

CN(C)C(C)=O

InChI

1S/C4H9NO/c1-4(6)5(2)3/h1-3H3

Clé InChI

FXHOOIRPVKKKFG-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Pictogrammes

Health hazardExclamation mark

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Eye Irrit. 2 - Repr. 1B

Code de la classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

147.2 °F - closed cup

Point d'éclair (°C)

64 °C - closed cup


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Sara Dumit et al.
Health physics, 119(6), 715-732 (2020-11-17)
The administration of chelation therapy to treat significant intakes of actinides, such as plutonium, affects the actinide's normal biokinetics. In particular, it enhances the actinide's rate of excretion, such that the standard biokinetic models cannot be applied directly to the
Fatma Kayaci et al.
Nanoscale, 6(17), 10224-10234 (2014-07-25)
Oxygen vacancies (V(O)s) in ZnO are well-known to enhance photocatalytic activity (PCA) despite various other intrinsic crystal defects. In this study, we aim to elucidate the effect of zinc interstitials (Zn(i)) and V(O)s on PCA, which has applied as well
Tony Reid et al.
The Lancet. Oncology, 16(9), 1133-1142 (2015-08-25)
Epigenetic alterations have been strongly associated with tumour formation and resistance to chemotherapeutic drugs, and epigenetic modifications are an attractive target in cancer research. RRx-001 is activated by hypoxia and induces the generation of reactive oxygen and nitrogen species that
Inês Farinha et al.
Carbohydrate polymers, 130, 455-464 (2015-06-17)
Purified chitin-glucan complex (CGCpure) was extracted from Komagataella pastoris biomass using a hot alkaline treatment, followed by neutralization and repeated washing with deionized water. The co-polymer thus obtained had a β-glucan:chitin molar ratio of 75:25 and low protein and inorganic
Chunling Wu et al.
Cell transplantation, 24(5), 891-907 (2014-05-20)
Genetically engineered stem cells that overexpress genes encoding therapeutic products can be exploited to correct metabolic disorders by repairing and regenerating diseased organs or restoring their function. Hair follicles are readily accessible and serve as a rich source of autologous

Articles

Find best practices for using Pellicon® Capsules in ADC processing as well as data from two studies using Pellicon® Capsules and Pellicon® cassettes in the ADC manufacturing process.

Find best practices for using Pellicon® Capsules in ADC processing as well as data from two studies using Pellicon® Capsules and Pellicon® cassettes in the ADC manufacturing process.

Find best practices for using Pellicon® Capsules in ADC processing as well as data from two studies using Pellicon® Capsules and Pellicon® cassettes in the ADC manufacturing process.

Find best practices for using Pellicon® Capsules in ADC processing as well as data from two studies using Pellicon® Capsules and Pellicon® cassettes in the ADC manufacturing process.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique