Accéder au contenu
Merck
Toutes les photos(3)

Key Documents

HADK2MAG-61K

Millipore

MILLIPLEX® Human Adipokine Magnetic Bead Panel 2 - Endocrine Multiplex Assay

The Human Adipokine Magnetic Bead Panel 2, using the Luminex xMAP technology, enables the simultaneous analysis of nine protein biomarkers in human serum and plasma samples.

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
eCl@ss :
32161000
Nomenclature NACRES :
NA.47

Niveau de qualité

Espèces réactives

human

Fabricant/nom de marque

Milliplex®

assay range

accuracy: 87%
(IL-8)

accuracy: 91%
(TNFα)

accuracy: 94%
(Insulin)

standard curve range: 0.64-10,000 pg/mL
(IL-8)

standard curve range: 0.64-10,000 pg/mL
(NGF)

standard curve range: 0.64-10,000 pg/mL
(TNF-α)

standard curve range: 0.96-15,000 pg/mL
(IL-6)

standard curve range: 1.3-20,000 pg/mL
(IL-1β)

standard curve range: 1.3-20,000 pg/mL
(MCP-1)

standard curve range: 38-600,000 pg/mL
(Leptin)

standard curve range: 9.6-150,000 pg/mL
(HGF)

standard curve range: 9.6-150,000 pg/mL
(Insulin)

inter-assay cv: <15%
intra-assay cv: <10%
(IL-1β)

inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)

inter-assay cv: <15%
intra-assay cv: <10%
(IL-8)

inter-assay cv: <15%
intra-assay cv: <10%
(Insulin)

inter-assay cv: <15%
intra-assay cv: <10%
(Leptin)

inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)

inter-assay cv: <15%
intra-assay cv: <10%
(NGF)

inter-assay cv: <20%
intra-assay cv: <10%
(TNFα)

Technique(s)

multiplexing: suitable

Méthode de détection

fluorometric (Luminex xMAP)

Conditions d'expédition

wet ice

Description générale

Previously the role of white adipose tissue was thought to be limited to energy storage and internal organ protection. The discovery of Leptin secretion from Adipocytes in 1994 led to the recognition that white adipose tissue is involved in a variety of metabolic and physiological processes. Adipocytes secrete several hormones called Adipokines with functions that include appetite and energy balance, insulin sensitivity and lipid metabolism.

The MILLIPLEX® Human Adipokine Panel 2 is a 9-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum or plasma samples: HGF, IL-1β, IL-6, IL-8, Insulin, Leptin, MCP-1, NGF and TNF-α. This kit uses a 96-well format, contains a lyophilized standard cocktail, 2 quality controls and can measure up to 38 samples in duplicate.

Panel Type: Metabolism

Spécificité

Cross Reactivty
Each antibody pair in a panel is highly specific and displays insignificant cross-reactivity to other analytes in the panel.

Application

  • Analytes: IL-1β, IL-6, IL-8, Insulin, Leptin, MCP-1, NGF, TNF-α
  • Recommended Sample Type: Human serum and plasma
  • Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma
  • Assay Run Time: Overnight (16-18 hours) at 2-8°C
  • Research Category: Metabolism
  • Research Subcategory: Endocrine

Caractéristiques et avantages

Design your multiplex kit by choosing available analytes within this panel.

Conditionnement

96-well plate
Everything you need in a single kit.

Stockage et stabilité

Recommended storage for kit components is 2 - 8°C.

Autres remarques

Please contact Technical Service for linearity of dilution.
Sensitivity: See kit protocol for individual sensitives.

Informations légales

MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pictogrammes

Skull and crossbonesEnvironment

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1

Code de la classe de stockage

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Altered promoter methylation of PDK4, IL1 B, IL6, and TNF after Roux-en Y gastric bypass.
Kirchner, H; Nylen, C; Laber, S; Barres, R; Yan, J; Krook, A; Zierath, JR; Naslund, E
Surgery for Obesity and Related Diseases : Official Journal of the American Society for Bariatric Surgery null
Insulin resistance is associated with Fibroblast Growth Factor-23 in stage 3-5 chronic kidney disease patients.
Garland, JS; Holden, RM; Ross, R; Adams, MA; Nolan, RL; Hopman, WM; Morton, AR
Journal of Diabetes and Its Complications null
Waist-to-height ratio, waist circumference and BMI as indicators of percentage fat mass and cardiometabolic risk factors in children aged 3-7 years.
Sijtsma, A; Bocca, G; L'abee, C; Liem, ET; Sauer, PJ; Corpeleijn, E
Clinical Nutrition (Edinburgh, Scotland) null
Annalisa Berzigotti et al.
Hepatology (Baltimore, Md.), 65(4), 1293-1305 (2016-12-21)
Obesity increases the risk of clinical decompensation in cirrhosis, possibly by increasing portal pressure. Whether weight reduction can be safely achieved through lifestyle (LS) changes (diet and exercise) in overweight/obese patients with cirrhosis, and if weight loss reduces portal pressure
Racial differences in HbA1c: a cross-sectional analysis of a Brazilian public primary care population.
de Miranda, VA; Cruz Filho, RA; de Oliveira, TS; Moscavitch, SD; Kang, HC; Miranda Chagas et al.
Primary Care Diabetes null

Contenu apparenté

Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.

Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.

Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.

Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique