1.50247

Supelco

Purospher® STAR NH2 (5 µm) HPLC Columns

L × I.D. 150 mm x 4.6 mm LiChroCART HPLC cartridge, manuCART holder required for use

Synonyme(s) :

Purospher® STAR NH2 (5 µm) LiChroCART 150-4.6

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41115709
Nomenclature NACRES :
SB.52

product name

Purospher® STAR NH2 (5 µm), L × I.D. 150 mm x 4.6 mm LiChroCART HPLC cartridge, manuCART holder required for use

Matériaux

stainless steel column

Niveau de qualité

Agence

suitable for USP L8

Gamme de produits

Purospher®

Caractéristiques

endcapped: no

Conditionnement

1 ea of

Ampleur du marquage

3.5% Carbon loading

Paramètres

250 bar pressure
60 °C max. temp.

Technique(s)

HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (Low - Medium)

Colonne, L × D.I.

15 cm × 4.6 mm

Superficie

330 m2/g

Matrice

fully porous particle

Groupe de la matrice active

NH2 bonding phase

Taille des particules

5 μm

Dimension de pores

120 Å pore size

operating pH range

2-7.5

Technique de séparation

hydrophilic interaction (HILIC)
normal phase
reversed phase

Température de stockage

no temp limit

Description générale

Purospher® STAR NH2, 5 µm HPLC columns are widely used for carbohydrate analysis, with a typical mobile phaseconsisting of acetonitrile and water. In terms of their polarity, these columns lie between bare silica and reversed-phase silica. Hence, Purospher® STAR NH2 can also be used as an ion-exchanger. In acidic solutions, the NH2-groups are protonated (-NH3 +X-) and therefore display the characteristics of a weak anion exchanger. Medium polarity Purospher® STAR NH2 columns possess hydrophilic as well as hydrophobic properties, thus can be used under both reversed-phase (HILIC) and normal-phase conditions. However, retention is weaker than on silica or RP-supports. Purospher® STAR NH2 columns are based on ultra-pure fully porous silica particles (Type B). Purospher® STAR NH2, 5 µm LiChroCART 150-4.6 is a cartridge column which requires a manuCART cartridge column holder part number 1.51486.0001.The recommended guard column is Purospher® STAR NH2 (5 µm) LiChroCART 4-4 part number 1.50267.0001. LiChroCART cartridge columns mounted with a manuCART cartridge column holder is hand-tight only and have therefore a maximum pressure stability of 250 bar.The column dimension of 150 mm length x 4.6 mm I.D. is the optimal choice for the HPLC separation of complex.Learn more about Purospher® STAR HPLC and UHPLC ColumnsLearn more about the Supelco HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection GuideBrochure: A Practical Guide to HPLC - Method Development Guide

Application

Intended to be used in the separation of alcohols,carboxylic acids, fat soluble vitamins, nucleotides, steroids, sugars, sugar alcohols, sweeteners, and water soluble vitamins.

Caractéristiques et avantages

  • Ultra-pure silica (99.999%)
  • Low silanol activity
  • Reproducible results from run-to-run and batch-to-batch

Remarque sur l'analyse

Pressure: ≤ 45 bar
Theoretical Plates (N/m) (2-Nitrotoluene): ≥ 50000
Symmetry (2-Nitrotoluene): 0.8 - 1.4
Capacity factor (2-Nitrotoluene): ≤ 3.0

Informations légales

LICHROCART is a trademark of Merck KGaA, Darmstadt, Germany
MANUCART is a trademark of Merck KGaA, Darmstadt, Germany
Purospher is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique