Skip to Content
Merck
All Photos(2)

Key Documents

1.00264

Supelco

Formic acid 98-100%

for analysis EMSURE® ACS,Reag. Ph Eur

Synonym(s):

Formic acid, Methanoic acid, Formylic acid

Sign Into View Organizational & Contract Pricing

Select a Size

100 ML
€37.60
1 L
€67.10
2.5 L
€131.00
25 L
€488.00
200 L
€2,930.00

€37.60


Estimated to ship on11 March 2025


Request a Bulk Order

Select a Size

Change View
100 ML
€37.60
1 L
€67.10
2.5 L
€131.00
25 L
€488.00
200 L
€2,930.00

About This Item

Linear Formula:
HCOOH
CAS Number:
Molecular Weight:
46.03
Beilstein:
1209246
MDL number:
UNSPSC Code:
12352106
EC Index Number:
200-579-1
NACRES:
NA.21

€37.60


Estimated to ship on11 March 2025


Request a Bulk Order

grade

ACS reagent

Quality Level

Agency

reag. Ph. Eur.

vapor density

1.6 (vs air)

vapor pressure

44.8 mmHg ( 20 °C)

product line

EMSURE®

Assay

≥98% (alkalimetric)

form

liquid

autoignition temp.

1004 °F

expl. lim.

12-38 % (v/v)
57 %

technique(s)

HPLC: suitable

impurities

≤500 ppm Acetic acid (CH3COOH)

evapn. residue

≤10 ppm

color

APHA: ≤10

refractive index

n20/D 1.370 (lit.)

pH

2.2 (20 °C, 10 g/L in H2O)

bp

100-101 °C (lit.)
101 °C/1013 hPa

mp

8.2-8.4 °C (lit.)

transition temp

flash point 49.5 °C

density

1.22 g/mL at 25 °C (lit.)

anion traces

chloride (Cl-): ≤5 ppm
sulfate (SO42-): ≤5 ppm
sulfite (SO32-): ≤10 ppm

cation traces

Ag: ≤0.020 ppm
Al: ≤0.050 ppm
Ba: ≤0.050 ppm
Be: ≤0.020 ppm
Bi: ≤0.10 ppm
Ca: ≤0.20 ppm
Cd: ≤0.050 ppm
Co: ≤0.020 ppm
Cr: ≤0.050 ppm
Cu: ≤0.020 ppm
Fe: ≤2.0 ppm
Ge: ≤0.050 ppm
K: ≤0.10 ppm
Li: ≤0.020 ppm
Mg: ≤0.50 ppm
Mn: ≤0.050 ppm
Mo: ≤0.020 ppm
NH4+: ≤10 ppm
Na: ≤0.50 ppm
Ni: ≤0.050 ppm
Pb: ≤0.020 ppm
Sr: ≤0.020 ppm
Ti: ≤0.10 ppm
Tl: ≤0.050 ppm
V: ≤0.050 ppm
Zn: ≤0.050 ppm
Zr: ≤0.10 ppm
heavy metals (as Pb): ≤10 ppm

SMILES string

OC=O

storage temp.

15-25°C

InChI

1S/CH2O2/c2-1-3/h1H,(H,2,3)

InChI key

BDAGIHXWWSANSR-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Related Categories

General description

for analysis EMSURE® ACS,Reag. Ph Eur

Application


  • Modified QuEChERS method combined with ultra performance liquid chromatography-tandem mass spectrometry for detection of cyclopiazonic acid in feeds: This study demonstrates the use of 98-100% formic acid in a modified QuEChERS method, enhancing the efficiency of toxin detection in animal feeds, crucial for maintaining food safety and environmental health (Peng et al., 2024).

  • Adapting Fabric Phase Sorptive Extraction as an Innovative Multitool for Sample Transfer and Extraction in Pharmacokinetic Analysis Followed by LC-MS Determination of Levofloxacin in Plasma Samples: This study utilizes formic acid in developing advanced extraction methods for pharmacokinetic analysis, critical for drug development and therapeutic monitoring in pharmaceutical research (Ekin Dolaksız et al., 2024).

  • Stability Indicating Method Development and Validation of Glycyrrhizin Using RP-HPLC-DAD: Application to Glycyrrhiza glabra Extract: This research uses formic acid in chromatographic analyses to ensure the stability and quality of herbal medicine compounds, relevant in both pharmaceutical and biotechnological fields (Lyngdoh et al., 2024).

Analysis Note

Assay (alkalimetric)≥ 98.0 %Color≤ 10 HazenAcetic acid (CH₃COOH)≤ 500 ppmChloride (Cl)≤ 5 ppmSulfate (SO₄)≤ 5 ppmSulfite (SO₃)≤ 10 ppmHeavy metals (as Pb)≤ 10 ppmAg (Silver)≤ 0.020 ppmAl (Aluminium)≤ 0.050 ppmBa (Barium)≤ 0.050 ppmBe (Beryllium)≤ 0.020 ppmBi (Bismuth)≤ 0.10 ppmCa (Calcium)≤ 0.20 ppmCd (Cadmium)≤ 0.050 ppmCo (Cobalt)≤ 0.020 ppmCr (Chromium)≤ 0.050 ppmCu (Copper)≤ 0.020 ppmFe (Iron)≤ 2.0 ppmGe (Germanium)≤ 0.050 ppmK (Potassium)≤ 0.10 ppmLi (Lithium)≤ 0.020 ppmMg (Magnesium)≤ 0.50 ppmMn (Manganese)≤ 0.050 ppmMo (Molybdenum)≤ 0.020 ppmNH₄ (Ammonium)≤ 10 ppmNa (Sodium)≤ 0.50 ppmNi (Nickel)≤ 0.050 ppmPb (Lead)≤ 0.020 ppmSr (Strontium)≤ 0.020 ppmTi (Titanium)≤ 0.10 ppmTl (Thallium)≤ 0.050 ppmV (Vanadium)≤ 0.050 ppmZn (Zinc)≤ 0.050 ppmZr (Zirconium)≤ 0.10 ppmEvaporation residue≤ 10 ppmDilution testpasses testACS, Ph Eur-Reagent
Expiry date : see product label

Legal Information

EMSURE is a registered trademark of Merck KGaA, Darmstadt, Germany

Not finding the right product?  

Try our Product Selector Tool.

Signal Word

Danger

Hazard Statements

Hazard Classifications

Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Eye Dam. 1 - Flam. Liq. 3 - Skin Corr. 1A

Supplementary Hazards

Storage Class Code

3 - Flammable liquids

WGK

WGK 1

Flash Point(F)

121.1 °F - closed cup

Flash Point(C)

49.5 °C - closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Zhina Hadisi et al.
Macromolecular bioscience, 20(4), e1900328-e1900328 (2020-02-23)
Burn injuries represent a major life-threatening event that impacts the quality of life of patients, and places enormous demands on the global healthcare systems. This study introduces the fabrication and characterization of a novel wound dressing made of core-shell hyaluronic

Articles

HPTLC-MS was used to analyze stevioside and rebaudioside in artificial sweeteners, stevia plants, cola and isotonic drinks with a minimum of sample preparation.

Discover an LC-MS/MS method for the analysis of 16 per- and polyfluoroalkyl compounds (PFAS) in milk using QuEChERS extraction technique following FDA C-010.02 guidelines.

Protocols

Thin layer chromatography coupled with mass spectrometry does not require substantial sample preparation. Energy drinks can be applied without dilution directly onto the TLC plate.

Method: Photometric determination with 3,3'-Diaminobenzidine

HPTLC–MS analysis of quinine in tonic water and caffeine in coffee and cola drinks.

Spectrophotometric determination of proline by the Ninhydrin method, per EN 1141 and German Food and Feed Code §64 LFBG 31.00-7.

Questions

1–2 of 2 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service