Direkt zum Inhalt
Merck
  • Biomonitoring occupational sevoflurane exposure at low levels by urinary sevoflurane and hexafluoroisopropanol.

Biomonitoring occupational sevoflurane exposure at low levels by urinary sevoflurane and hexafluoroisopropanol.

Toxicology letters (2014-12-03)
Maria Luisa Scapellato, Mariella Carrieri, Isabella Maccà, Fabiola Salamon, Andrea Trevisan, Maurizio Manno, Giovanni Battista Bartolucci
ZUSAMMENFASSUNG

This study aimed to correlate environmental sevoflurane levels with urinary concentrations of sevoflurane (Sev-U) or its metabolite hexafluoroisopropanol (HFIP) in order to assess and discuss the main issues relating to which biomarker of sevoflurane exposure is best, and possibly suggest the corresponding biological equivalent exposure limit values. Individual sevoflurane exposure was measured in 100 healthcare operators at five hospitals in north-east Italy using the passive air sampling device Radiello(®), and assaying Sev-U and HFIP concentrations in their urine collected at the end of the operating room session. All analyses were performed by gas chromatography-mass spectrometry. Environmental sevoflurane levels in the operating rooms were also monitored continuously using an infrared photoacoustic analyzer. Our results showed very low individual sevoflurane exposure levels, generally below 0.5 ppm (mean 0.116 ppm; range 0.007-0.940 ppm). Sev-U and HFIP concentrations were in the range of 0.1-17.28 μg/L and 5-550 μg/L, respectively. Both biomarkers showed a statistically significant correlation with the environmental exposure levels (Sev-U, r=0.49; HFIP, r=0.52), albeit showing fairly scattered values. Sev-U values seem to be influenced by peaks of exposure, especially at the end of the operating-room session, whereas HFIP levels by exposure on the previous day, the data being consistent with the biomarkers' very different half-lives (2.8 and 19 h, respectively). According to our results, both Sev-U and HFIP are appropriate biomarkers for assessing sevoflurane exposure at low levels, although with some differences in times/patterns of exposure. More work is needed to identify the best biomarker of sevoflurane exposure and the corresponding biological equivalent exposure limit values.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
1,1,1,3,3,3-Hexafluor-2-propanol, ≥99%
radiello Kartuschen-Adsorbenzien, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello Dreieckige Trägerplatte, pk of 20
radiello Diffusionskörper, white, configured for general use, pk of 20
radiello Kartuschen-Adsorbenzien, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
radiello Kartuschen-Adsorbenzien, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello Diffusionskörper, blue, configured for sampling light sensitive compounds, pk of 20
radiello Diffusionskörper, yellow, configured for reduced sampling rates, pk of 20
Sigma-Aldrich
Kreatinin, anhydrous, ≥98%
radiello Kartuschen-Adsorbenzien, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
radiello Methylenblau-Kalibrierstandard für H2S (Schwefelwasserstoff), pkg of 100 mL
radiello Freiluft-Schutzvorrichtung, pk of 10
Supelco
1,1,1,3,3,3-Hexafluor-2-propanol, for GC derivatization, LiChropur, ≥99.8%
radiello Strichcode-Etiketten, pk of 198
radiello Vertikaler Adapter, threaded for standard use, pk of 20
radiello BTEX/VOC Starter Kit, CS2 Desorption
radiello BTEX/VOC Starter Kit, Thermal Desorption
Supelco
radiello BTEX-Kalibrierkit (Thermische Desorption)
Supelco
Kreatinin, Pharmaceutical Secondary Standard; Certified Reference Material
radiello Filtrations-Kit, pk of 20
radiello Hydrogen Sulfide Starter Kit
radiello Kartuschen-Adsorbenzien, for sampling Anaesthetic Gases/Vapors, matrix SS net with mix of mol sieve and activated charcoal (30-50 mesh), pk of 20
Sevofluran, European Pharmacopoeia (EP) Reference Standard
radiello Anesthetic Gases and Vapor Sampler
radiello Leerröhrchen zur Aufbewahrung, polypropylene (with stopper), volume 12 mL, pk of 100
radiello Feld-Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello Leerröhrchen zur Aufbewahrung, glass (with stopper), volume 2.8 mL, pk of 100
Supelco
radiello Aldehyd-Kalibrierstandard, 50 μg/mL each component in acetonitrile, pkg of 10 mL
Supelco
radiello BTEX-Kalibrierkit (CS2 Desorption)
radiello Klemmen, suspending Radiello triangular support plate, pk of 20