Direkt zum Inhalt
Merck

T9659

Sigma-Aldrich

TAPS

BioXtra, ≥99.5% (titration)

Synonym(e):

N-[Tris(hydroxymethyl)methyl]-3-aminopropansulfonsäure, [(2-Hydroxy-1,1-bis(hydroxymethyl)ethyl)amino]-1-propansulfonsäure

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C7H17NO6S
CAS-Nummer:
Molekulargewicht:
243.28
Beilstein:
2452420
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12161700
PubChem Substanz-ID:
NACRES:
NA.25

Produktlinie

BioXtra

Assay

≥99.5% (titration)

Form

powder

Verunreinigungen

≤0.005% Phosphorus (P)
≤0.1% Insoluble matter

Glührückstand

≤0.1%

Nützlicher pH-Bereich

7.7-9.1

pKa 

8.4

mp (Schmelzpunkt)

230-235 °C (dec.)

Löslichkeit

H2O: 1 M, clear, colorless

Anionenspuren

chloride (Cl-): ≤0.05%

Kationenspuren

Al: ≤0.0005%
Ca: ≤0.001%
Cu: ≤0.0005%
Fe: ≤0.0005%
K: ≤0.005%
Mg: ≤0.0005%
NH4+: ≤0.05%
Na: ≤0.005%
Pb: ≤0.001%
Zn: ≤0.0005%

Absorption

≤0.05 at 260 in H2O at 1 M
≤0.05 at 280 in H2O at 1 M

Anwendung(en)

diagnostic assay manufacturing

SMILES String

OCC(CO)(CO)NCCCS(O)(=O)=O

InChI

1S/C7H17NO6S/c9-4-7(5-10,6-11)8-2-1-3-15(12,13)14/h8-11H,1-6H2,(H,12,13,14)

InChIKey

YNLCVAQJIKOXER-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 3

Flammpunkt (°F)

>230.0 °F - closed cup

Flammpunkt (°C)

> 110 °C - closed cup

Persönliche Schutzausrüstung

Eyeshields, Gloves, type N95 (US)


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Z Zeng et al.
Analytical biochemistry, 252(1), 110-114 (1997-11-05)
High-resolution capillary electrophoresis sizing of preformed complexes of bis-intercalating fluorescent dyes with double-stranded DNA has been demonstrated using hydroxyethylcellulose and 3-[tris-(hydroxymethyl) methylamino]-1-propanesulfonic acid-tetrapentylammonium (Taps-NPe+4) buffers (S. M. Clark and R. A. Mathies, Anal. Chem. 69, 1355-1363, 1997). Such capillary electrophoresis
Seung-ick Oh et al.
TheScientificWorldJournal, 2014, 957548-957548 (2014-07-06)
Somatic cells were directly converted to functional neurons through the use of a combination of transcription factors, including Ascl1, Brn2, and Myt1l. However, a major limitation is the lack of a reliable source of cell-replacement therapy for neurological diseases. Here
D Liang et al.
Electrophoresis, 21(17), 3600-3608 (2001-03-29)
A new method to introduce the concentration gradient into the capillary has been developed and its application to DNA capillary electrophoresis is presented. The concentration gradient produced by mixing 5% w/v polyacrylamide-co-poly(N-dimethylacrylamide) (PAM-co-PDMA) solution and 1 x Tris/N-tris(hydroxymethyl)methyl-3-amino-propanesulfonic acid/EDTA (TT)
Patrick Kwan et al.
Journal of the American Chemical Society, 137(42), 13556-13565 (2015-10-06)
We report the first direct electrochemical characterization of the impact of oxygen on the hydrogen oxidation activity of an oxygen-tolerant, group 3, soluble [NiFe]-hydrogenase: hydrogenase I from Pyrococcus furiosus (PfSHI), which grows optimally near 100 °C. Chronoamperometric experiments were used
Myra Noemi Chávez et al.
Biomaterials, 75, 25-36 (2015-10-17)
The use of artificial tissues in regenerative medicine is limited due to hypoxia. As a strategy to overcome this drawback, we have shown that photosynthetic biomaterials can produce and provide oxygen independently of blood perfusion by generating chimeric animal-plant tissues

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.