Direkt zum Inhalt
Merck

PHR1678

Supelco

Bicalutamid

Pharmaceutical Secondary Standard; Certified Reference Material

Synonym(e):

Bicalutamid (CDX)

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
C18H14F4N2O4S
CAS-Nummer:
Molekulargewicht:
430.37
MDL-Nummer:
UNSPSC-Code:
41116107
PubChem Substanz-ID:
NACRES:
NA.24

Qualität

certified reference material
pharmaceutical secondary standard

Qualitätsniveau

Agentur

traceable to BP 1115
traceable to Ph. Eur. Y0001444
traceable to USP 1071202

API-Familie

bicalutamide

Analysenzertifikat (CofA)

current certificate can be downloaded

Verpackung

pkg of 1 g

Methode(n)

HPLC: suitable
gas chromatography (GC): suitable

Anwendung(en)

pharmaceutical (small molecule)

Format

neat

Lagertemp.

2-8°C

SMILES String

CC(O)(CS(=O)(=O)c1ccc(F)cc1)C(=O)Nc2ccc(C#N)c(c2)C(F)(F)F

InChI

1S/C18H14F4N2O4S/c1-17(26,10-29(27,28)14-6-3-12(19)4-7-14)16(25)24-13-5-2-11(9-23)15(8-13)18(20,21)22/h2-8,26H,10H2,1H3,(H,24,25)

InChIKey

LKJPYSCBVHEWIU-UHFFFAOYSA-N

Angaben zum Gen

human ... AR(367)

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards. Bicalutamide is a non-steroidal peripheral androgen receptor inhibitor. Its mode of action involves inhibiting androgen by binding to cytosol androgen receptors in the target tissue.

Anwendung

Bicalutamide may be used as a pharmaceutical reference standard for the determination of the analyte by high performance liquid chromatography and UV spectrophotometry.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Biochem./physiol. Wirkung

Bicalutamide (CDX) is a non-steriodal Androgen Receptor (AR) antagonist and a pure antiandrogen. It acts via balancing histone acetylation/deacetylation and recruitment of coregulators. Bicalutamide (CDX) abolishes androgen-mediated expression. For example, MMP13 upregulation in prostate cancer, PLZF (promyelocytic leukemia zinc finger protein), and GADD45γ (growth arrest and DNA damage inducible, gamma). Bicalutamide (CDX) is inhibited by non-genomic, transcription-independent stimulation of PI3K/AKT phosphorylation by androgens.

Hinweis zur Analyse

These secondary standards offer multi-traceability to the USP, EP and BP primary standards, where they are available.

Sonstige Hinweise

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Fußnote

To see an example of a Certificate of Analysis for this material enter LRAA6123 in the slot below. This is an example certificate only and may not be the lot that you receive.

Empfohlene Produkte

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Piktogramme

Health hazardEnvironment

Signalwort

Danger

Gefahreneinstufungen

Aquatic Chronic 1 - Carc. 2 - Repr. 1B

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Choose from one of the most recent versions:

Analysenzertifikate (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Development and validation of RP-HPLC method for the estimation of Bicalutamide in pure and pharmaceutical dosage forms
Rao AL, et al.
Rasayan Journal of Chemistry, 2(2), 512-515 (2009)
Development of an electrochemical method for the determination of bicalutamide at the SWCNT/CPE in pharmaceutical preparations and human biological fluids
Pandit UJ, et al.
Analytical Methods : Advancing Methods and Applications, 7(24), 10192-10198 (2015)
Determination and validation of UV spectrophotometric method for estimation of bicalutamide tablet
Swamivelmanickam M, et al,.
International Journal of ChemTech Research, 1(4), 1189-1193 (2009)
Development and validation of a stability indicating HPLC Method for determination of Bicalutamide in pharmaceutical formulations
Reddy GNK, et al.
International Journal of Pharmacy and Biological Sciences, 2(4), 134-149 (2012)
Emiliano Ventura et al.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment, 37(8), 1253-1263 (2020-05-14)
Selective androgen receptor modulators (SARMs) are a class of new emerging "designer" steroid compounds gaining popularity over more well established anabolic-androgenic steroids (AAS) amongst both non-professional and elite athletes. Moreover, due to their anabolic activity, SARM compounds may also potentially

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.