Direkt zum Inhalt
Merck

89683

Millipore

Toluol

suitable for HPLC, ≥99.7% (GC)

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
C6H5CH3
CAS-Nummer:
Molekulargewicht:
92.14
Beilstein:
635760
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12190000
PubChem Substanz-ID:

Dampfdichte

3.2 (vs air)

Qualitätsniveau

Dampfdruck

22 mmHg ( 20 °C)
26 mmHg ( 25 °C)

Assay

≥99.7% (GC)

Form

liquid

Selbstzündungstemp.

997 °F

Haltbarkeit

limited shelf life, expiry date on the label

Expl.-Gr.

7 %

Methode(n)

HPLC: suitable

Verunreinigungen

≤0.05% water

Abdampfrückstand

≤0.001%

Brechungsindex

n/D 1.496 (lit.)
n20/D 1.497

bp

110-111 °C (lit.)

mp (Schmelzpunkt)

-93 °C (lit.)

Dichte

0.865 g/mL at 25 °C (lit.)

Lösungsmittelstärke ε (Al2O3)

0.29

λ

1 cm path, H2O reference

UV-Absorption

λ: 285 nm Amax: 1.0
λ: 310 nm Amax: 0.1
λ: 350 nm Amax: 0.01

SMILES String

Cc1ccccc1

InChI

1S/C7H8/c1-7-5-3-2-4-6-7/h2-6H,1H3

InChIKey

YXFVVABEGXRONW-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Empfohlene Produkte

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Signalwort

Danger

Gefahreneinstufungen

Aquatic Chronic 3 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

Zielorgane

Central nervous system

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 3

Flammpunkt (°F)

39.9 °F - closed cup

Flammpunkt (°C)

4.4 °C - closed cup

Persönliche Schutzausrüstung

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Choose from one of the most recent versions:

Analysenzertifikate (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Liang Guo et al.
Journal of chromatography. A, 1286, 9-15 (2013-03-19)
For the first time, a novel one-step sample preparation method that combines microwave assisted extraction and solvent bar microextraction (MAE-SBME) with analysis by gas chromatography-mass spectrometry (GC-MS), was developed for the fast and efficient determination of polycyclic aromatic hydrocarbons (PAHs)
Elke Persch et al.
ChemMedChem, 9(8), 1880-1891 (2014-05-03)
The causative agents of the parasitic disease human African trypanosomiasis belong to the family of trypanosomatids. These parasitic protozoa exhibit a unique thiol redox metabolism that is based on the flavoenzyme trypanothione reductase (TR). TR was identified as a potential
Perrine Hoet et al.
Critical reviews in toxicology, 38(2), 127-170 (2008-02-09)
Noise is the most common preventable cause of irreversible sensorineural hearing loss. During recent years, the results of experimental and human investigations have raised the level of concern about the potential ototoxicity of chemical agents and their interaction with noise.
Yoko Yamakoshi et al.
Faraday discussions, 173, 287-296 (2014-12-04)
The photoinduced reactive oxygen species (ROS) generation from several water-soluble fullerenes was examined. Macromolecular or small molecular water-soluble fullerene complexes/derivatives were prepared and their (1)O(2) and O(2)˙(-) generation abilities were evaluated by ESR spin-trapping methods. As a result, efficient (1)O(2)
Emma Oakton et al.
Dalton transactions (Cambridge, England : 2003), 43(40), 15138-15142 (2014-09-03)
Herein, we report the preparation of small and narrowly distributed (2.1 ± 0.5 nm) Ag nanoparticles supported on passivated silica, where the surface OH groups are replaced by OSiMe3 functionalities. This synthetic method involves the grafting of silver(I) bis(trimethylsilyl)amide ([AgN(SiMe3)2]4)

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.