Direkt zum Inhalt
Merck

S2GPU05RE

Millipore

Millipore® Stericup® Schnellverschluss-Vakuumfiltrationssystem

Millipore® Stericup® Quick Release Vacuum Filtration System

pore size 0.22 μm, polyethersulfone membrane, funnel capacity 500 mL, pack of 12 ea

Synonym(e):

SCGPU05RE, Stericup Quick Release-GP steriles Vakuumfiltrationssystem

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41104914
eCl@ss:
32031623
NACRES:
NB.24
Preise und Verfügbarkeit sind derzeit nicht verfügbar.

Materialien

polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing

Qualitätsniveau

Sterilität

sterile; irradiated

Produktlinie

Stericup®

Leistungsmerkmale

hydrophilic

Verpackung

pack of 12 ea

Parameter

45 °C max. temp.

Beschreibung

2.4 mL (hold-up volume)

Methode(n)

sterile filtration: suitable

Höhe

263 mm

Kapazität

500 mL

Durchmesser

12.5 cm

Filterdurchm.

73 mm

Filtrationsfläche

40 cm2

Trichterkapazität

500 mL

Matrix

Express PLUS

Porengröße

0.22 μm pore size

Fitting

inlet funnel
outlet flask (Receiver)

Versandbedingung

ambient

Allgemeine Beschreibung

Das sterile Stericup-Quick Release-GP-Vakuumfiltrationssystem besteht aus einem Steritop-500-ml-Flaschenaufsatzfilter mit einer fließoptimierten PES Express PLUS-Membran mit 0,22 µm Porengröße und einer 500-ml-Filtratsammelflasche zur Sterilfiltration von Gewebekulturmedien, Protein und DNA.

Anwendung

Die Stericup® und Steritop® Systeme wurden entwickelt, um Schaumbildung und Proteindenaturierung zu reduzieren und gleichzeitig den Durchfluss zu maximieren. Sie können für die sterile Vakuumfiltration von wässrigen Lösungen wie Gewebekulturmedien und biologischen Flüssigkeiten eingesetzt werden.

  • Gewebekulturmedien +/- Additive
  • Puffer
  • Biologische Lösungen
Nur für Forschungszwecke

Leistungsmerkmale und Vorteile

  • Der Schnellverschluss-Filtertrichter wird mit nur einer Vierteldrehung von der Auffangflasche—getrennt, was die Wahrscheinlichkeit eines Verschüttens verringert und die Handhabung auf dem Labortisch oder unter der Haube.
  • Die deutlich lesbare Produktkennzeichnung auf dem Steritop® Filtertrichter die Membraneigenschaften einschließlich Zusammensetzung und Porengröße an und ermöglicht so eine unmittelbare, anwendungsgerechte Produktauswahl.
  • Der Deckel mit Klickverschluss und Flansch hat eine spezielle Form für einen sicheren Griff unter nassen oder trockenen Bedingungen.—Die taktile Rückmeldung bestätigt den sicheren Verschluss. Damit wird die Möglichkeit eines Verschüttens oder einer Kontamination des sterilisierten Inhalts deutlich verringert.
  • Die große mattierte Beschriftungsfläche auf der Auffangflasche und die hellere Kappenfarbe erleichtern die eindeutige Beschriftung für eine verbesserte Lesbarkeit und weniger Unleserlichkeiten.
  • Die Verschlusskappe liegt auf der Seite auf, um das Risiko einer Kontamination zu vermeiden.
  • Die Auffangbehälter sind platzsparend stapelbar.

Rechtliche Hinweise

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Stericup is a registered trademark of Merck KGaA, Darmstadt, Germany

Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Artikel

Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.

Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.

Ensure optimal cell culture outcomes with ultrapure, endotoxin-free water. Learn about the impact of water impurities on mammalian cell cultures and how to achieve optimal cell growth.

Overview on how to maintain proper cell culture laboratory safety including steps on performing lab risk assessments, surface disinfection, biohazard and waste removal. Free ECACC handbook download.

Verwandter Inhalt

What are you filtering out? What do you want to keep? Pick the right membrane for your filtration.

Learn how to effectively filter fetal bovine serum (FBS) using Stericup® Quick Release vacuum filtration devices, including flow test data and analysis.

This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.

Fragen

1-10 von 16 Fragen  
  1. What is the Corning alternative for the product CLS431097, which is a Corning® bottle-top vacuum filter system with specific features like a polyethersulfone membrane, pore size of 0.22 μm, membrane area of 33.2 cm2, and a filter capacity of 500 mL?

    1 Antwort
    1. The recommended alternative product is S2GPU05RE, Stericup Quick Release-GP Sterile Vacuum Filtration System from Millipore. This system includes a 500 mL Steritop bottle top filter unit utilizing a 0.22 µm pore size fast flow PES Express PLUS membrane, along with a 500 mL receiver flask for the sterilization of tissue culture media, protein, and DNA.

      Hilfreich?

  2. What tubing can be used with Stericup® and Steritop® vacuum filters?

    What tubing can be used with Stericup® and Steritop® vacuum filters?

    1 Antwort
    1. Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004

      Hilfreich?

  3. What is the expiration date of Stericup® and Steritop® filters?

    1 Antwort
    1. Typically 3 years from sterilization.

      Hilfreich?

  4. Can Stericup® bottles be placed inside freezers for long-term storage of media?

    1 Antwort
    1. You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.

      Hilfreich?

  5. Can Stericup® and Steritop® filters be reused?

    1 Antwort
    1. All Stericup® and Steritop® filters were developed for single use, disposable processing.

      Hilfreich?

  6. What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?

    1 Antwort
    1. All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
      *Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.

      Hilfreich?

  7. What is the chemical compatibility of the various Stericup® and Steritop® filters?

    What is the chemical compatibility of the various Stericup® and Steritop® filters?

    1 Antwort
    1. Hilfreich?

  8. What Bacterial Endotoxins Test is used?

    1 Antwort
    1. The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.

      Hilfreich?

  9. Can we filter oil-type liquids with Stericup® filters?

    Can we filter oil-type liquids with Stericup® filters?

    1 Antwort
    1. Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf

      Hilfreich?

  10. Which type of pump should be used with Stericup® and Steritop® vacuum filters?

    Which type of pump should be used with Stericup® and Steritop® vacuum filters?

    1 Antwort
    1. We recommend our Chemical Duty Pump: https://www.sigmaaldrich.com/product/mm/wp6111560

      Hilfreich?

1-10 von 16 Fragen  

Bewertungen

Aktive Filter

  1. 1 Bewertung ohne Rezension

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.