Direkt zum Inhalt
Merck

1.05554

Supelco

TLC-Aluminiumblätter, Kieselgel 60 F₂₅₄

pkg of 25 sheets, sheet L × W 20 cm × 20 cm, aluminum support

Synonym(e):

Dünnschichtchromatographie-Aluplatten

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

25 UNITS
208,00 €

208,00 €


Voraussichtliches Versanddatum26. März 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
25 UNITS
208,00 €

About This Item

UNSPSC-Code:
41115711
NACRES:
NB.21
Schichtdicke:
200 μm
Blatt L × B:
20 cm × 20 cm
Leistungsmerkmale:
binder Organic Polymer
fluorescent indicator
Porengröße:
60 Å medium pore diameter

208,00 €


Voraussichtliches Versanddatum26. März 2025


Bulk-Bestellung anfordern

Materialien

aluminum support
silica gel 60 matrix

Qualitätsniveau

Leistungsmerkmale

binder Organic Polymer
fluorescent indicator

Verpackung

pkg of 25 sheets

Methode(n)

thin layer chromatography (TLC): suitable

Schichtdicke

200 μm

Blatt L × B

20 cm × 20 cm

Partikelgröße

10-12 μm

Porengröße

60 Å medium pore diameter

Lagertemp.

2-30°C

Allgemeine Beschreibung

25 Aluminiumbleche 20 x 20 cm
Unsere klassischen Kieselgel-DC-Platten kombinieren unser bewährtes Kieselgel 60 und ein einzigartiges Polymerbindemittel. Dadurch entsteht eine stark klebende und harte Oberfläche, die weder Blasen wirft noch reißt und die ohne Beschädigung mit einem Bleistift beschrieben werden kann.

Anwendung

Aluminium-DC-Platte, Kieselgel-beschichtet mit Fluoreszenzindikator F254. Die Kieselgel-DC-Platten werden in Größen von 20x20 cm in Packungen à 25 Stück für die Dünnschichtchromatographie geliefert.

Verlinkung

Ersetzt: 5554-7; 5554

Hinweis zur Analyse

Spezifische Oberfläche (nach BET; 5-Pkt-Messung): 480–540 m²/g
Porenvolumen (N₂-isotherm): 0,74–0,84 ml/g
d 50 (Laserbeugung, Kornanalyse): 9,7 - 11,7 µm
Schichtdicke: 175–225 µm
Dickenschwankung pro Platte: ≤ 30 µm
A) Farbstofftest
Bleu VIF Organol: 11–25
Ceresschwarz: 34–48
Ceresviolett BRN: 52–67
Trennzahl: ≥ 10,5
B) Steroidtest
Hydrocortison: 25–37
Reichstein S: 37–49
Methyltestosteron: 42–54
Typischer Wert gemessen an einer konditionierten Folie
Eluent A) Toluol (45 % rel. Feuchte)
Eluent B) Ethylacetat/Toluol (95/5 v/v; 20 % rel. Feuchte)

Lagerklassenschlüssel

11 - Combustible Solids


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Artikel

Thin Layer Chromatography Troubleshooting: This article details TLC tips and tricks that one must consider while performing different steps of the technique.

HPTLC plates provide superior separation, speed, and sensitivity, making them ideal for advanced qualitative and quantitative analysis.

Fragen

1-3 von 3 Fragen  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 Antwort
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Hilfreich?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 Antwort
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Hilfreich?

  3. What does the number 60 mean?

    1 Antwort
    1. The number "60" in silica gel 60 refers to the 60 Å average pore diameter in the stationary phase.

      Hilfreich?

Bewertungen

Kein Beurteilungswert

Aktive Filter

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.