Direkt zum Inhalt
Merck

H-083

Supelco

25-Hydroxyvitamin D3 -Lösung

100 μg/mL in ethanol, ampule of 1 mL, certified reference material, Cerilliant®

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

1 ML
136,00 €

136,00 €


Versandbereit am22. April 2025Details


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
1 ML
136,00 €

About This Item

Empirische Formel (Hill-System):
C27H44O2
CAS-Nummer:
Molekulargewicht:
400.64
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
41116107
PubChem Substanz-ID:
NACRES:
NA.24

136,00 €


Versandbereit am22. April 2025Details


Bulk-Bestellung anfordern

Qualität

certified reference material

Qualitätsniveau

Form

liquid

Leistungsmerkmale

Snap-N-Spike®/Snap-N-Shoot®

Verpackung

ampule of 1 mL

Hersteller/Markenname

Cerilliant®

Konzentration

100 μg/mL in ethanol

Anwendung(en)

clinical testing
clinical testing
clinical testing

Format

single component solution

Lagertemp.

−70°C

SMILES String

O.C[C@H](CCCC(C)(C)O)[C@H]1CC[C@H]2C(\CCC[C@]12C)=C\C=C3\C[C@@H](O)CCC3=C

InChI

1S/C27H44O2/c1-19-10-13-23(28)18-22(19)12-11-21-9-7-17-27(5)24(14-15-25(21)27)20(2)8-6-16-26(3,4)29/h11-12,20,23-25,28-29H,1,6-10,13-18H2,2-5H3/b21-11+,22-12-/t20-,23+,24-,25+,27-/m1/s1

InChIKey

JWUBBDSIWDLEOM-DTOXIADCSA-N

Angaben zum Gen

human ... VDR(7421)

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Eine zertifizierte Dotierlösung® von 25-Hydroxyvitamin D3, einem Prohormon, dessen Spiegel im Blut dazu verwendet wird, den Versorgungszustand mit Vitamin D zu bestimmen. Dieser Lösungsstandard ist geeignet für essenzielle quantitative Anwendungen in Forschung und Klinik, beispielsweise: Herstellung von Kontrollen und Kalibratoren für LC/UV- und LC-MS/MS-Assays; als Standards für System-Tuning/Eignungsfeststellung; Linearitätsverifikation; interne Leistungstests sowie zur OEM-Verwendung bei der Herstellung von Reagenzien, Entwicklung von Tests und IQ/OQ für Instrumente. Das stabile, quantitative Lösungsformat hat wesentliche Anwendungsvorteile, beispielsweise Materialersparnis, effizientere Arbeitsabläufe und praktische Anwendung. Das lagerstabile Format Snap-N-Spike® erspart dem Labor das aufwändige Einwägen und bietet die Möglichkeit, Dotierungen mit bekannter Analytenkonzentration der gewählten Matrix unmittelbar vor der Verwendung vorzunehmen.

Anwendung

25-Hydroxyvitamin D3 kann als zertifiziertes Referenzmaterial (CRM) für die Bestimmung des Analyten in biologischen Proben[1][2][3] mittels chromatographischer Verfahren verwendet werden.

Rechtliche Hinweise

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Piktogramme

FlameExclamation mark

Signalwort

Danger

H-Sätze

Gefahreneinstufungen

Eye Irrit. 2 - Flam. Liq. 2

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 1

Flammpunkt (°F)

57.2 °F - closed cup

Flammpunkt (°C)

14 °C - closed cup


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

New aspects of the plasma carrier protein for 25-hydroxycholecalciferol in vertebrates.
H Van Baelen et al.
Annals of the New York Academy of Sciences, 538, 60-68 (1988-01-01)
J H Soares et al.
Poultry science, 74(12), 1919-1934 (1995-12-01)
Vitamin D is a complex of secosteroids that must undergo metabolic alterations to reach optimal biological activity. The parent compounds 1) ergocalciferol (D2) and 2) cholecalciferol (D3) can be synthesized in the leaves of many plants or in the skin
Maria Samefors et al.
European journal of endocrinology, 170(5), 667-675 (2014-02-13)
Institutionalised elderly people at northern latitudes may be at elevated risk for vitamin D deficiency. In addition to osteoporosis-related disorders, vitamin D deficiency may influence several medical conditions conferring an increased mortality risk. The aim of this study was to
Antrison Morris et al.
Poultry science, 93(8), 1951-1956 (2014-06-17)
Three experiments were conducted to study the effects of 25-hydroxycholecalciferol supplementation on BW gain, IL-1β, and 1α-hydroxylase mRNA expression in different organs of broiler chickens following a lipopolysaccharide (LPS) injection. In experiment I, birds were fed a basal diet supplemented
A method for simultaneous determination of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in human plasma by using two steps of high-performance liquid chromatography
Okano T, et al.
J. Nutr. Sci. Vitaminol., 27(1), 43-54 (1981)

Artikel

Vitamin D deficiency affects bone health, highlighting its vital role in calcium absorption and bone growth.

UHPLC separation of Vitamin D Metabolites using Supel Carbon LC column ensures excellent peak shape and sensitivity.

Novel sample prep technique coupled with the unique selectivity of the Ascentis Express F5 column enables a fast and simplified bioanalytical method for associated vitamin D metabolites.

Using HybridSPE-Phospholipid, Ascentis Express, and Other LC-MS Workflow Components

Alle anzeigen

Chromatograms

application for HPLC

Fragen

1-2 von 2 Fragen  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 Antwort
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Hilfreich?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 Antwort
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Hilfreich?

Bewertungen

Kein Beurteilungswert

Aktive Filter

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.