Direkt zum Inhalt
Merck

GF29969724

Blei

foil, not light tested, 150x150mm, thickness 0.02mm, 99.99+%

Synonym(e):

Blei

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

1 EA
2.210,00 €

2.210,00 €


Voraussichtliches Versanddatum16. April 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
1 EA
2.210,00 €

About This Item

Empirische Formel (Hill-System):
Pb
CAS-Nummer:
Molekulargewicht:
207.20
MDL-Nummer:
UNSPSC-Code:
12141723
PubChem Substanz-ID:
NACRES:
NA.23

2.210,00 €


Voraussichtliches Versanddatum16. April 2025


Bulk-Bestellung anfordern

Assay

99.99%

Form

foil

Hersteller/Markenname

Goodfellow 299-697-24

Widerstandsfähigkeit

20.65 μΩ-cm

Größe

150X150 mm

bp

1740 °C (lit.)

mp (Schmelzpunkt)

327.4 °C (lit.)

SMILES String

[Pb]

InChI

1S/Pb

InChIKey

WABPQHHGFIMREM-UHFFFAOYSA-N

Allgemeine Beschreibung

For updated SDS information please visit www.goodfellow.com.

Rechtliche Hinweise

Product of Goodfellow

Piktogramme

Health hazardEnvironment

Signalwort

Danger

Gefahreneinstufungen

Aquatic Acute 1 - Aquatic Chronic 1 - Lact. - Repr. 1A - STOT RE 1 Oral

Zielorgane

Central nervous system,Blood,Immune system,Kidney

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

nwg

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

A Janhom et al.
Dento maxillo facial radiology, 29(1), 20-27 (2000-02-02)
To determine the interaction between image noise and file compression, with special emphasis on the accuracy of caries diagnosis. Fifty-nine bitewing radiographs of patients were taken simultaneously with Ektaspeed Plus (Eastman-Kodak, Rochester, NY, USA) film without lead foil and the
George X Ding
Medical physics, 29(11), 2459-2463 (2002-12-05)
This study investigates a possible cause of reported significant dose discrepancies between Monte Carlo calculations and measurements in the buildup region for high-energy photon beams in large fields. A proposed hypothesis was that the discrepancy was caused by a source
I Sewerin
Tandlaegebladet, 94(12), 483-486 (1990-09-01)
The lead foil of dental x-ray film packets may cause a number of artifacts; especially well known are the "tractor treads" and "herringbone patterns" following a backward filmpositioning in the patient's mouth. In the present paper a specific and seldomly
Antonio Lopez Medina et al.
Physics in medicine and biology, 49(1), 17-32 (2004-02-20)
Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage
H Fujita et al.
The British journal of radiology, 82(978), 504-508 (2009-01-21)
It is useful to utilise a computed radiography system with a combination of storage phosphor plates and therapy cassettes for portal images. However, the therapy cassette has some disadvantages. The objective of the present study was to determine whether the

Fragen

Bewertungen

Kein Beurteilungswert

Aktive Filter

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.