Direkt zum Inhalt
Merck

GF03972102

Blei

foil, 100x100mm, thickness 0.5mm, as rolled, 99.95%

Synonym(e):

Blei

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Empirische Formel (Hill-System):
Pb
CAS-Nummer:
Molekulargewicht:
207.20
MDL-Nummer:
UNSPSC-Code:
12141723
PubChem Substanz-ID:
NACRES:
NA.23

Assay

99.95%

Form

foil

Hersteller/Markenname

Goodfellow 039-721-02

Widerstandsfähigkeit

20.65 μΩ-cm

L × B × Dicke

100 mm × 100 mm × 0.5 mm

bp

1740 °C (lit.)

mp (Schmelzpunkt)

327.4 °C (lit.)

SMILES String

[Pb]

InChI

1S/Pb

InChIKey

WABPQHHGFIMREM-UHFFFAOYSA-N

Allgemeine Beschreibung

For updated SDS information please visit www.goodfellow.com.

Rechtliche Hinweise

Product of Goodfellow

Piktogramme

Health hazardEnvironment

Signalwort

Danger

Gefahreneinstufungen

Aquatic Acute 1 - Aquatic Chronic 1 - Lact. - Repr. 1A - STOT RE 1 Oral

Zielorgane

Central nervous system,Blood,Immune system,Kidney

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

nwg

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

M Bourgeois et al.
Health physics, 62(6), 546-552 (1992-06-01)
A significant amount of radiation escapes the rear of an image receptor in conventional dental radiographic procedures despite the placement of a lead-containing backing at the rear of the film pack. The purpose of this investigation was to place additional
Motoaki Kato et al.
Nihon Hoshasen Gijutsu Gakkai zasshi, 61(8), 1158-1169 (2005-09-01)
In projection radiography, stationary grids are indispensable accessories to the improvement of diagnostic imaging. On the other hand, they are becoming one of the issues facing digital image processing. The lead foil that composes the grid can produce moiré on
I Sewerin
Tandlaegebladet, 94(12), 483-486 (1990-09-01)
The lead foil of dental x-ray film packets may cause a number of artifacts; especially well known are the "tractor treads" and "herringbone patterns" following a backward filmpositioning in the patient's mouth. In the present paper a specific and seldomly
George X Ding
Medical physics, 29(11), 2459-2463 (2002-12-05)
This study investigates a possible cause of reported significant dose discrepancies between Monte Carlo calculations and measurements in the buildup region for high-energy photon beams in large fields. A proposed hypothesis was that the discrepancy was caused by a source
D W Rogers
Medical physics, 26(4), 533-537 (1999-05-05)
Data are presented to allow the photon beam quality specifier being used in the new AAPM TG-51 protocol, %dd(10)x, to be extracted from depth-dose data measured with a 1 mm lead foil either 50 cm or 30 cm from the

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.